Seismic evaluation and upgrading of RC buildings with weak open ground stories

被引:14
|
作者
Antonopoulos, T. A. [1 ]
Anagnostopoulos, S. A. [1 ]
机构
[1] Univ Patras, Dept Civil Engn, Patras 26500, Greece
关键词
reinforced concrete buildings; open ground story; inelastic earthquake response; seismic evaluation; seismic strengthening; steel bracing; FRAMES; PERFORMANCE; RETROFIT; MEMBERS;
D O I
10.12989/eas.2012.3.3_4.611
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The inelastic earthquake response of existing, reinforced concrete buildings with an open ground story, designed according to the old Greek codes, is investigated before and after their seismic strengthening with steel braces restricted to the open ground stories. The seismic performance evaluation is based on Part 3 of Eurocode 8 for assessment and retrofitting of buildings. Three and five-story, symmetric and non-symmetric buildings are subjected to a set of seven pairs of synthetic accelerograms, compatible with the design spectrum, and conclusions are drawn regarding the effectiveness of the strengthening solutions. Seismic behavior of the selected models confirms results of previous work regarding the insufficient capacity of the open ground stories for design level earthquakes. It is also shown that strengthening only the weak ground story, a choice having the substantial advantage of low cost and continued usage of the building during its seismic retrofitting, can remove the inherent weakness without shifting the problem to the stories above and thus making such buildings at least as strong as those without a weak first story. This partial strengthening is possible for symmetric as well as eccentric buildings, in which torsion plays a further detrimental role.
引用
收藏
页码:611 / 628
页数:18
相关论文
共 50 条
  • [1] Seismic upgrading of nonductile RC moment frame buildings
    Sasani, M
    Bertero, VV
    Anderson, JC
    COMPOSITE AND HYBRID STRUCTURES, VOLS 1 AND 2, 2000, : 819 - 828
  • [2] Seismic evaluation of open ground storey RC buildings with realistic functional openings in upper storey infills
    Kurmi, P. L.
    Haldar, P.
    STRUCTURES, 2025, 72
  • [3] Global Interventions for Seismic Upgrading of Substandard RC Buildings
    Thermou, G. E.
    Pantazopoulou, S. J.
    Elnashai, A. S.
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2012, 138 (03): : 387 - 401
  • [4] Global interventions for seismic upgrading of substandard RC buildings
    Thermou, G.E.
    Pantazopoulou, S.J.
    Elnashai, A.S.
    Journal of Structural Engineering (United States), 2012, 138 (03): : 387 - 401
  • [5] Seismic Evaluation of Vertically Irregular RC Buildings
    Bhattacharjee, Sayanti
    Sarkar, Pradip
    RECENT TRENDS IN WAVE MECHANICS AND VIBRATIONS, WMVC 2018, 2020, : 287 - 294
  • [6] Seismic response assessment and upgrading of a complex of seven RC buildings using FRPs
    Panagiotakos, T. B.
    Kosmopoulos, A. J.
    Kolias, B.
    TAILOR MADE CONCRETE STRUCTURES: NEW SOLUTIONS FOR OUR SOCIETY, 2008, : 145 - 145
  • [7] Upgrading the seismic capacity of existing RC buildings using buckling restrained braces
    Abou-Elfath, Hamdy
    Ramadan, Mostafa
    Alkanai, Fozeya Omar
    ALEXANDRIA ENGINEERING JOURNAL, 2017, 56 (02) : 251 - 262
  • [8] Use of RC Shear Walls in Strengthening of Open Ground Story RC Buildings
    Parchuri, Chetan P.
    Kaushik, Hemant B.
    PROCEEDINGS OF THE 8TH INTERNATIONAL CONFERENCE ON STRUCTURAL DYNAMICS, EURODYN 2011, 2011, : 419 - 426
  • [9] SEISMIC DESIGN OF OPEN-STOREY INFILLED RC BUILDINGS
    Fardis, M. N.
    Negro, P.
    Bousias, S. N.
    Colombo, A.
    JOURNAL OF EARTHQUAKE ENGINEERING, 1999, 3 (02) : 173 - 197
  • [10] EVALUATION OF SEISMIC RESPONSE OF RC BUILDINGS LOADED TO FAILURE
    AKTAN, AE
    BERTERO, VV
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1987, 113 (05): : 1092 - 1108