Analytical efficiency curve for coaxial germanium detectors

被引:8
作者
Svec, A. [1 ]
机构
[1] Slovak Inst Metrol, Ctr Ionizing Radiat, Bratislava 84255, Slovakia
关键词
radionuclide activity; gamma-ray spectrometry; efficiency curve;
D O I
10.1016/j.apradiso.2008.02.070
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
A new semi-empirical analytical expression of gamma-ray spectrometer efficiency curves has been proposed and a method for their parameters determination has been developed. The complete curve consists of two parts, first being the basic detector characterization curve of low number of parameters and second one being a corrective curve, which adjusts the final results to the required and achievable accuracy. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:786 / 791
页数:6
相关论文
共 49 条
[41]   Application of the Monte Carlo method for the efficiency calibration of CsI and NaI detectors for gamma-ray measurements from terrestrial samples [J].
Baccouche, S. ;
Al-Azmi, D. ;
Karunakara, N. ;
Trabelsi, A. .
APPLIED RADIATION AND ISOTOPES, 2012, 70 (01) :227-232
[42]   Performances of different efficiency calibration methods of high-purity-germanium gamma-ray spectrometry in an inter-comparison exercise [J].
Yang, Bao-Lu ;
Zhou, Qiang ;
Zhang, Jing ;
Yao, Shuai-Mo ;
Li, Ze-Shu ;
Li, Wen-Hong ;
Tuo, Fei .
NUCLEAR SCIENCE AND TECHNIQUES, 2019, 30 (03)
[43]   Performances of different efficiency calibration methods of high-purity-germanium gamma-ray spectrometry in an inter-comparison exercise [J].
Bao-Lu Yang ;
Qiang Zhou ;
Jing Zhang ;
Shuai-Mo Yao ;
Ze-Shu Li ;
Wen-Hong Li ;
Fei Tuo .
Nuclear Science and Techniques, 2019, 30 (03) :12-17
[44]   Performances of different efficiency calibration methods of high-purity-germanium gamma-ray spectrometry in an inter-comparison exercise [J].
Bao-Lu Yang ;
Qiang Zhou ;
Jing Zhang ;
Shuai-Mo Yao ;
Ze-Shu Li ;
Wen-Hong Li ;
Fei Tuo .
Nuclear Science and Techniques, 2019, 30
[45]   Determination of full-energy peak and total efficiency functions for Ge-detectors by iteration calculation using a mixed radionuclide source [J].
Ishizu, H. ;
Yamada, T. .
APPLIED RADIATION AND ISOTOPES, 2018, 134 :163-166
[46]   A trapezoid approach for the experimental total-to-peak efficiency curve used in the determination of true coincidence summing correction factors in a HPGe detector [J].
Sahiner, Eren ;
Meric, Niyazi .
RADIATION PHYSICS AND CHEMISTRY, 2014, 96 :50-55
[47]   Derivation of an efficiency-calibration simulation for a well-type HPGe detector using the Monte Carlo approach and analytical techniques [J].
Belgin, E. Eren ;
Aycik, G. A. .
RADIATION MEASUREMENTS, 2015, 73 :36-45
[48]   NaI cubic detector full-energy peak efficiency, including coincidence and self-absorption corrections for rectangular sources using analytical method [J].
Abbas, Mahmoud, I ;
Elsafi, Mohamed ;
Gouda, Mona M. ;
Abd-Elzaher, Mohamed ;
Hamzawy, A. ;
Badawi, Mohamed S. ;
Thabet, Abouzeid A. ;
Noureddine, Salam ;
El-Khatib, Ahmed M. .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2021, 327 (01) :251-258
[49]   Well-type NaI(Tl) detector efficiency using analytical technique and ANGLE 4 software based on radioactive point sources located out the well cavity [J].
El-Khatib, Ahmed M. ;
Badawi, Mohamed S. ;
Thabet, Abouzeid A. ;
Jovanovic, Slobodan I. ;
Gouda, Mona M. ;
Mohamed, Moustafa M. ;
Dlabac, Aleksandar D. ;
Abd-Elzaher, Mohamed ;
Mihaljevic, Nikola N. ;
Abbas, Mahmoud I. .
CHINESE JOURNAL OF PHYSICS, 2016, 54 (03) :338-346