Analytical efficiency curve for coaxial germanium detectors

被引:8
|
作者
Svec, A. [1 ]
机构
[1] Slovak Inst Metrol, Ctr Ionizing Radiat, Bratislava 84255, Slovakia
关键词
radionuclide activity; gamma-ray spectrometry; efficiency curve;
D O I
10.1016/j.apradiso.2008.02.070
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
A new semi-empirical analytical expression of gamma-ray spectrometer efficiency curves has been proposed and a method for their parameters determination has been developed. The complete curve consists of two parts, first being the basic detector characterization curve of low number of parameters and second one being a corrective curve, which adjusts the final results to the required and achievable accuracy. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:786 / 791
页数:6
相关论文
共 49 条
  • [1] Application of PENELOPE code to the efficiency calibration of coaxial germanium detectors
    Jurado Vargas, M.
    Guerra, A. L.
    APPLIED RADIATION AND ISOTOPES, 2006, 64 (10-11) : 1319 - 1322
  • [2] A practical and general methodology for efficiency calibration of coaxial Ge detectors
    Barba-Lobo, A.
    Bolivar, J. P.
    MEASUREMENT, 2022, 197
  • [3] A hybrid method to determine efficiency curve of HPGe detectors
    Ozben, Cenap S.
    Emirhan, Erhan M.
    APPLIED RADIATION AND ISOTOPES, 2009, 67 (06) : 1110 - 1113
  • [4] Extension of the efficiency calibration of germanium detectors using the GESPECOR software
    Arnold, D
    Sima, O
    APPLIED RADIATION AND ISOTOPES, 2004, 61 (2-3) : 117 - 121
  • [5] A simple methodology for characterization of germanium coaxial detectors by using Monte Carlo simulation and evolutionary algorithms
    Guerra, J. G.
    Rubiano, J. G.
    Winter, G.
    Guerra, A. G.
    Alonso, H.
    Arnedo, M. A.
    Tejera, A.
    Gil, J. M.
    Rodriguez, R.
    Martel, P.
    Bolivar, J. P.
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2015, 149 : 8 - 18
  • [6] Monte Carlo calculation of the efficiency calibration curve for HPGe detectors
    Bhattacharya, Tam
    Nagaiah, N.
    Reddy, B. Ram Mohan
    Sharma, P. K.
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 2018, 56 (08) : 628 - 630
  • [7] A new efficiency calibration methodology for different atmospheric filter geometries by using coaxial Ge detectors
    A. Barba-Lobo
    J. P. Bolívar
    Air Quality, Atmosphere & Health, 2023, 16 : 1207 - 1214
  • [8] A new efficiency calibration methodology for different atmospheric filter geometries by using coaxial Ge detectors
    Barba-Lobo, A.
    Bolivar, J. P.
    AIR QUALITY ATMOSPHERE AND HEALTH, 2023, 16 (06): : 1207 - 1214
  • [9] DETEFF:: An improved Monte Carlo computer program for evaluating the efficiency in coaxial gamma-ray detectors
    Diaz, N. Cornejo
    Vargas, M. Jurado
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 586 (02): : 204 - 210
  • [10] The active area shadow-shielding effect on detection efficiency of collimated broad energy germanium detectors
    Altavilla, Massimo
    Remetti, Romolo
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 739 : 10 - 20