Corneal stromal thickness changes after myopic laser cornea refractive surgery

被引:17
作者
Del Barrio, Jorge L. Alio [2 ]
Canto-Cerdan, Mario [1 ]
El Bahrawy, Mohamed [1 ,3 ]
Casanova, Laura [1 ]
Garcia, Maria J. [1 ]
Cavas, Francisco [4 ]
Alio, Jorge L. [1 ,2 ]
机构
[1] Vissum Alicante, Cornea Cataract & Refract Surg Unit, Alicante, Spain
[2] Univ Miguel Hernandez, Sch Med, Div Ophthalmol, Alicante, Spain
[3] Watany Res & Dev Ctr, Cairo, Egypt
[4] Tech Univ Cartagena, Dept Struct Construct & Graph Express, Cartagena, Spain
关键词
ARTEMIS; LASIK; READOUT;
D O I
10.1097/j.jcrs.0000000000000765
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the postoperative behavior of the central corneal stomal thickness after myopic femto-laser-assisted in-situ keratomileusis (LASIK) and small-incision lenticule extraction (SMILE) by using combined anterior segment optical coherence tomography and a Placido disk topographer and to compare the accuracy of both laser machines in predicting the real stromal change. Setting: Vissum Miranza, Alicante, Spain. Study design: Prospective, observational, comparative study. Methods: The VisuMax 500 kHz femtosecond laser (FS) and the Amaris 750 excimer laser were used for the correction of myopia with or without myopic astigmatism. Central and paracentral stomal thicknesses (ST) and 6.0 mm corneal aberrometry were obtained with the MS39 topographer. Laser-predicted stromal consumption was recorded (maximum lenticule thickness for SMILE and central ablation depth for LASIK). Visual and refractive outcomes were also evaluated. Total follow-up was 6 months. Results: 77 LASIK eyes were matched with 77 SMILE eyes. Mean preoperative spherical equivalent (SE) was 3.92 +/- 1.67 diopters (D) for LASIK and 4.02 +/- 1.63 D for SMILE (P = .356). After LASIK, ST parameters showed significant rethickening between months 1 and 3 (+4.38 mu m for central ST; P < .001), remaining stable thereafter. After SMILE, all ST parameters remained stable from month 1. Stomal ablation prediction was higher for SMILE compared with LASIK for all SE ranges, although postoperatively such differences were significant only for ametropias <= 4 D. At 6 months, mean SMILE laser prediction error was -13.21 +/- 7.00 mu m, whereas LASIK prediction showed better accuracy (+0.92 +/- 8.16 mu M; P < .001). Conclusions: The accuracy of the Amaris 750 excimer laser in predicting the stromal consumption after LASIK was better than the VisuMax FS laser for SMILE. Although SMILE ST remained stable from month 1, after LASIK, mild stromal rethickening was observed up to the third month.
引用
收藏
页码:334 / 341
页数:8
相关论文
共 18 条
[11]   Epithelial Thickness Profile Changes Induced by Myopic LASIK as Measured by Artemis Very High-frequency Digital Ultrasound [J].
Reinstein, Dan Z. ;
Srivannaboon, Sabong ;
Gobbe, Marine ;
Archer, Timothy J. ;
Silverman, Ronald H. ;
Sutton, Hugo ;
Coleman, D. Jackson .
JOURNAL OF REFRACTIVE SURGERY, 2009, 25 (05) :444-450
[12]  
Roberts C, 2000, J REFRACT SURG, V16, P407
[13]   Spectral-Domain Optical Coherence Tomography Epithelial and Flap Thickness Mapping in Femtosecond Laser-Assisted In Situ Keratomileusis [J].
Rocha, Karolinne Maia ;
Krueger, Ronald R. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 158 (02) :293-301
[14]   Repeatability of automatic measurements by a new anterior segment optical coherence tomographer combined with Placido topography and agreement with 2 Scheimpflug cameras [J].
Savini, Giacomo ;
Schiano-Lomoriello, Domenico ;
Hoffer, Kenneth J. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (04) :471-478
[15]   Small incision lenticule extraction (SMILE) lenticule thickness readout compared to change in axial length measurements with the IOLMaster [J].
Tay, Eugene ;
Bajpai, Ram .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2020, 258 (04) :917-924
[16]   Corneal Epithelial Thickness Intrasubject Repeatability and its Relation With Visual Limitation in Keratoconus [J].
Vega-Estrada, Alfredo ;
Mimouni, Michael ;
Espla, Elias ;
Alto del Barrio, Jorge ;
Alio, Jorge L. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2019, 200 :255-262
[17]   Changes in Corneal Volume at Different Areas and Its Correlation with Corneal Biomechanics after SMILE and FS-LASIK Surgery [J].
Wei, Pinghui ;
Cheng, George P. M. ;
Zhang, Jiamei ;
Ng, Alex L. K. ;
Chan, Tommy C. Y. ;
Jhanji, Vishal ;
Wang, Yan .
JOURNAL OF OPHTHALMOLOGY, 2020, 2020
[18]   Investigation of predictability and influence factors of the achieved lenticule thickness in small incision lenticule extraction [J].
Wu, Fang ;
Yin, Houfa ;
Chen, Xinyi ;
Yang, Yabo .
BMC OPHTHALMOLOGY, 2020, 20 (01)