Superficial ultrasound shear wave speed measurements in soft and hard elasticity phantoms: repeatability and reproducibility using two ultrasound systems

被引:65
作者
Dillman, Jonathan R. [1 ]
Chen, Shigao [2 ]
Davenport, Matthew S. [3 ]
Zhao, Heng [2 ]
Urban, Matthew W. [2 ]
Song, Pengfei [2 ]
Watcharotone, Kuanwong [4 ]
Carson, Paul L. [5 ]
机构
[1] Univ Michigan Hlth Syst, CS Mott Childrens Hosp, Dept Radiol, Sect Pediat Radiol, Ann Arbor, MI 48109 USA
[2] Mayo Coll Med, Dept Physiol & Biomed Engn, Rochester, MN USA
[3] Univ Michigan Hlth Syst, Dept Radiol, Div Abdominal Imaging, Ann Arbor, MI 48109 USA
[4] Univ Michigan, MICHR, Ann Arbor, MI 48109 USA
[5] Univ Michigan Hlth Syst, Dept Radiol, Div Basic Radiol Sci, Ann Arbor, MI 48109 USA
基金
美国国家卫生研究院;
关键词
Shear wave elastography; Acoustic radiation force impulse (ARFI); Shear wave speed; Elasticity phantom; Reproducibility; Repeatability; Measurement; Ultrasound; FORCE IMPULSE ARFI; NORMAL VALUES; HEALTHY-CHILDREN; MR ELASTOGRAPHY; LIVER FIBROSIS; RADIATION; STIFFNESS; EXPERIENCE;
D O I
10.1007/s00247-014-3150-6
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
There is a paucity of data available regarding the repeatability and reproducibility of superficial shear wave speed (SWS) measurements at imaging depths relevant to the pediatric population. To assess the repeatability and reproducibility of superficial shear wave speed measurements acquired from elasticity phantoms at varying imaging depths using three imaging methods, two US systems and multiple operators. Soft and hard elasticity phantoms manufactured by Computerized Imaging Reference Systems Inc. (Norfolk, VA) were utilized for our investigation. Institution No. 1 used an Acuson S3000 US system (Siemens Medical Solutions USA, Malvern, PA) and three shear wave imaging method/transducer combinations, while institution No. 2 used an Aixplorer US system (SuperSonic Imagine, Bothell, WA) and two different transducers. Ten stiffness measurements were acquired from each phantom at three depths (1.0 cm, 2.5 cm and 4.0 cm) by four operators at each institution. Student's t-test was used to compare SWS measurements between imaging techniques, while SWS measurement agreement was assessed with two-way random effects single-measure intra-class correlation coefficients (ICCs) and coefficients of variation. Mixed model regression analysis determined the effect of predictor variables on SWS measurements. For the soft phantom, the average of mean SWS measurements across the various imaging methods and depths was 0.84 +/- 0.04 m/s (mean +/- standard deviation) for the Acuson S3000 system and 0.90 +/- 0.02 m/s for the Aixplorer system (P = 0.003). For the hard phantom, the average of mean SWS measurements across the various imaging methods and depths was 2.14 +/- 0.08 m/s for the Acuson S3000 system and 2.07 +/- 0.03 m/s Aixplorer system (P > 0.05). The coefficients of variation were low (0.5-6.8%), and interoperator agreement was near-perfect (ICCs a parts per thousand yenaEuro parts per thousand 0.99). Shear wave imaging method and imaging depth significantly affected measured SWS (P < 0.0001). Superficial shear wave speed measurements in elasticity phantoms demonstrate minimal variability across imaging method/transducer combinations, imaging depths and operators. The exact clinical significance of this variation is uncertain and may change according to organ and specific disease state.
引用
收藏
页码:376 / 385
页数:10
相关论文
共 19 条
[1]   Supersonic shear imaging: A new technique for soft tissue elasticity mapping [J].
Bercoff, J ;
Tanter, M ;
Fink, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2004, 51 (04) :396-409
[2]   Pediatric MR elastography of hepatic fibrosis: principles, technique and early clinical experience [J].
Binkovitz, Larry A. ;
El-Youssef, Mounif ;
Glaser, Kevin J. ;
Yin, Meng ;
Binkovitz, Anna K. ;
Ehman, Richard L. .
PEDIATRIC RADIOLOGY, 2012, 42 (04) :402-409
[3]   Acoustic radiation force impulse (ARFI) in the evaluation of the renal parenchymal stiffness in paediatric patients with vesicoureteral reflux: preliminary results [J].
Bruno, Costanza ;
Caliari, Giuliana ;
Zaffanello, Marco ;
Brugnara, Milena ;
Zuffante, Michele ;
Cecchetto, Mariangela ;
Minniti, Salvatore ;
Pedot, Alice ;
Talamini, Giorgio ;
Pozzi-Mucelli, Roberto .
EUROPEAN RADIOLOGY, 2013, 23 (12) :3477-3484
[4]   Shear wave elastography for breast masses is highly reproducible [J].
Cosgrove, David O. ;
Berg, Wendie A. ;
Dore, Caroline J. ;
Skyba, Danny M. ;
Henry, Jean-Pierre ;
Gay, Joel ;
Cohen-Bacrie, Claude .
EUROPEAN RADIOLOGY, 2012, 22 (05) :1023-1032
[5]   Tissue Quantification With Acoustic Radiation Force Impulse Imaging: Measurement Repeatability and Normal Values in the Healthy Liver [J].
D'Onofrio, Mirko ;
Gallotti, Anna ;
Mucelli, Roberto Pozzi .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (01) :132-136
[6]   Acoustic Radiation Force Elasticity Imaging in Diagnostic Ultrasound [J].
Doherty, Joshua R. ;
Trahey, Gregg E. ;
Nightingale, Kathryn R. ;
Palmeri, Mark L. .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2013, 60 (04) :685-701
[7]   NORMAL VALUES OF LIVER SHEAR WAVE VELOCITY IN HEALTHY CHILDREN ASSESSED BY ACOUSTIC RADIATION FORCE IMPULSE IMAGING USING A CONVEX PROBE AND A LINEAR PROBE [J].
Fontanilla, Teresa ;
Canas, Teresa ;
Macia, Araceli ;
Alfageme, Marta ;
Gutierrez Junquera, Carolina ;
Malalana, Ana ;
Luz Cilleruelo, Maria ;
Roman, Enriqueta ;
Miralles, Maria .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2014, 40 (03) :470-477
[8]  
Hall T. J., 2013, IEEE INT ULTR S PRAG
[9]   Acoustic radiation force impulse (ARFI) elastography for the noninvasive diagnosis of liver fibrosis in children [J].
Hanquinet, Sylviane ;
Rougemont, Anne-Laure ;
Courvoisier, Delphine ;
Rubbia-Brandt, Laura ;
Mclin, Valerie ;
Tempia, Michela ;
Anooshiravani, Mehrak .
PEDIATRIC RADIOLOGY, 2013, 43 (05) :545-551
[10]   Acoustic radiation force impulse imaging-normal values of liver stiffness in healthy children [J].
Hanquinet, Sylviane ;
Courvoisier, Delphine ;
Kanavaki, Aikaterini ;
Dhouib, Amira ;
Anooshiravani, Mehrak .
PEDIATRIC RADIOLOGY, 2013, 43 (05) :539-544