Impact of Coronary Calcium on Outcome Following Sirolimus-Eluting Stent Implantation

被引:18
|
作者
Tanabe, Kengo [1 ,2 ]
Kishi, Satoru [1 ]
Aoki, Jiro [1 ]
Tanimoto, Shuzou [1 ]
Onuma, Yoshinobu [1 ]
Yachi, Sen [1 ]
Taniwaki, Masanori [1 ]
Nakajima, Yoshifumi [1 ]
Nakajima, Hiroyoshi [1 ]
Hara, Kazuhiro [1 ]
Isobe, Mitsuaki [2 ]
机构
[1] Mitsui Mem Hosp, Div Cardiol, Tokyo 101, Japan
[2] Tokyo Med & Dent Univ, Dept Cardiovasc Med, Tokyo, Japan
关键词
SERIAL INTRAVASCULAR ULTRASOUND; SPIRAL COMPUTED-TOMOGRAPHY; ARTERY-DISEASE; BALLOON ANGIOPLASTY; CALCIFICATION; RESTENOSIS; QUANTIFICATION; DEPLOYMENT; TRIAL; RESPONSES;
D O I
10.1016/j.amjcard.2011.03.075
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
There remain a small but sizable number of patients who develop restenosis after sirolimus-eluting stent (SES) implantation. However, the cause of SES restenosis has not been fully elucidated. The study population consisted of 52 patients with 69 lesions who underwent noninvasive coronary imaging by 64-slice multidetector computed tomography before SES deployment. Agatston calcium scores in target lesions were measured. All patients underwent follow-up coronary angiography at 8 months. Three coronary segments (in stent, proximal edge, and distal edge) were analyzed by quantitative coronary angiography. Agatston calcium score in target lesions averaged 214.7. Late lumen losses in the proximal edge, stent, and distal edge were 0.16 +/- 0.45, 0.47 +/- 0.58, and 0.07 +/- 0.29 mm, respectively. Lesions with restenosis at follow-up showed a trend to produce higher preprocedural calcium scores (629) compared to those without restenosis (153, p = 0.08). There was a significant positive correlation between lesion calcium score and in-stent late lumen loss (r = 0.47, p <0.01). In conclusion, assessment of coronary calcium by multidetector computed tomography might be useful to predict outcomes after SES implantation. (C) 2011 Elsevier Inc. All rights reserved. (Am J Cardiol 2011;108:514-517)
引用
收藏
页码:514 / 517
页数:4
相关论文
共 50 条
  • [1] Late Restenosis Following Sirolimus-Eluting Stent Implantation
    Kuriyama, Nehiro
    Kobayashi, Yoshio
    Nakama, Tatsuya
    Mine, Daigo
    Nishihira, Kensaku
    Shimomura, Mitsuhiro
    Nomura, Katsumasa
    Ashikaga, Keiichi
    Matsuyama, Akihiko
    Shibata, Yoshisato
    JACC-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (01) : 123 - 128
  • [2] Incidence and clinical impact of coronary stent fracture after sirolimus-eluting stent implantation
    Aoki, Jiro
    Nakazawa, Gaku
    Tanabe, Kengo
    Hoye, Angela
    Yamamoto, Hirosada
    Nakayama, Tomohiro
    Onuma, Yoshinobu
    Higashikuni, Yasutomi
    Otsuki, Syuji
    Yagishita, Atsuhiko
    Yachi, Sen
    Nakajima, Hiroyoshi
    Hara, Kazuhiro
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2007, 69 (03) : 380 - 386
  • [3] Sirolimus-eluting coronary stent
    Vishnevetsky, D
    Patel, P
    Tijerino, H
    Gandhi, PJ
    AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY, 2004, 61 (05) : 449 - 456
  • [4] Impact of metabolic syndrome on clinical and angiographic outcome after sirolimus-eluting stent implantation
    Stellbrink, Ekaterina
    Schroeder, Joerg
    Grawe, Armin
    Goebbels, Rainer
    Blindt, Ruediger
    Kelm, Malte
    Hoffmann, Rainer
    CORONARY ARTERY DISEASE, 2007, 18 (08) : 601 - 606
  • [5] Frequency, predictors and outcome of stent fracture after sirolimus-eluting stent implantation
    Umeda, Hisashi
    Gochi, Tomoko
    Iwase, Mitsunori
    Izawa, Hideo
    Shimizu, Takeshi
    Ishiki, Ryoji
    Inagaki, Haruo
    Toyama, Junji
    Yokota, Mitsuhiro
    Murohara, Toyoaki
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2009, 133 (03) : 321 - 326
  • [6] Severe multivessel coronary spasm after sirolimus-eluting stent implantation
    Tomassini, Francesco
    Varbella, Ferdinando
    Gagnor, Andrea
    Infantino, Vincenzo
    Luceri, Stefania
    Conte, Maria Rosa
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2009, 10 (06) : 485 - 488
  • [7] Effects of sirolimus-eluting stent on calcified coronary lesions
    Jian-Jun, Li
    Bo, Xu
    Yue-Jin, Yang
    Ji-Lin, Chen
    Shu-Bing, Qiao
    Wei-Hua, Ma
    Xue-Wen, Qin
    Min, Yao
    Hai-Bo, Liu
    Yong-Jian, Wu
    Jin-Qing, Yuan
    Jue, Chen
    Shi-Jie, You
    Jun, Dai
    Ran, Xia
    Run-Lin, Gao
    CHINESE MEDICAL JOURNAL, 2008, 121 (01) : 6 - 11
  • [8] Mechanism of Edge Restenosis After Sirolimus-Eluting Stent Implantation
    Ichimoto, Eiji
    Fujimoto, Yoshihide
    Kubo, Kenichirou
    Miyayama, Tomoaki
    Iwata, Yo
    Kitahara, Hideki
    Kobayashi, Yoshio
    JOURNAL OF INVASIVE CARDIOLOGY, 2012, 24 (02) : 55 - 57
  • [9] Impact of Hinge Motion on In-Stent Restenosis after Sirolimus-Eluting Stent Implantation
    Ino, Yasushi
    Kubo, Takashi
    Shimamura, Kunihiro
    Satogami, Keiryou
    Kitabata, Hironori
    Kimura, Keizo
    Hirata, Kumiko
    Komukai, Kenichi
    Tanimoto, Takashi
    Ishibashi, Kohei
    Mizukoshi, Masato
    Imanishi, Toshio
    Akasaka, Takashi
    CIRCULATION, 2010, 122 (21)
  • [10] Comparison of Long-term Outcomes Following Sirolimus-eluting Stent vs Paclitaxel-eluting Stent Implantation in Patients with Long Calcified Coronary Lesions
    Hur, Seung-Ho
    Cho, Yun-Kyeong
    Nam, Chang-Wook
    Kim, Hyungseop
    Han, Seong-Wook
    Kim, Yoon-Nyun
    Park, Hee-Joon
    Park, Jong-Seon
    Shin, Dong-Gu
    Kim, Young-Jo
    Shim, Bong-Sup
    Yang, Tae-Hyun
    Kim, Dae-Kyeong
    Kim, Doo-Il
    Kim, Dong-Soo
    Kim, Kwon-Bae
    CLINICAL CARDIOLOGY, 2009, 32 (11) : 633 - 638