Risk of stroke early after implantation of a left ventricular assist device

被引:10
作者
Samura, Takaaki [1 ]
Yoshioka, Daisuke [1 ]
Toda, Koichi [1 ]
Sakaniwa, Ryoto [2 ]
Shimizu, Mikito [3 ]
Miyagawa, Shigeru [1 ]
Yoshikawa, Yasushi [1 ]
Hata, Hiroki [1 ]
Saito, Shunsuke [1 ]
Sakata, Yasushi [4 ]
Sawa, Yoshiki [1 ]
机构
[1] Osaka Univ, Grad Sch Med, Dept Cardiovasc Surg, Yamadaoka 2-2, Suita, Osaka 5650871, Japan
[2] Osaka Univ, Grad Sch Med, Dept Publ Hlth, Osaka, Japan
[3] Osaka Univ, Grad Sch Med, Dept Neurol, Osaka, Japan
[4] Osaka Univ, Grad Sch Med, Dept Cardiol, Osaka, Japan
关键词
left ventricular assist device; low cardiac output; pump thrombosis; stroke; HEART MATE II; INTERAGENCY REGISTRY; HEMORRHAGIC STROKE; PUMP THROMBOSIS; MORTALITY; HEMOLYSIS;
D O I
10.1016/j.jtcvs.2018.06.031
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Stroke is one of the major adverse events after left ventricular assist device implantation. Risk of stroke is the highest immediately after left ventricular assist device implantation and then increases again in chronic periods. There is no study that has analyzed risk factors for stroke in acute phase. We investigated the risk factors for stroke in the acute phase after left ventricular assist device implantation in the present study. Methods: Between October 2005 and December 2016, 158 consecutive patients (mean age, 43 +/- 14 years; 34% were women) underwent continuous-flow left ventricular assist device (50 HeartMate II [Abbott Medical, Abbott Park, III], 38 DuraHeart [Terumo Heart, Ann Arbor, Mich], 33 Jarvik2000 [Jarvik Heart, New York, NY], 23 EVAHEART [Sun Medical, Moriyama City, Japan], 14 HeartWare [Framingham, Mass]) implantation in our institution. We analyzed the risk factors for a symptomatic stroke within 90 days after left ventricular assist device implantation. Results: Stroke occurred in 28 patients in the acute phase after left ventricular assist device implantation. Multivariate analysis revealed that low cardiac output (odds ratio, 0.25; 0.07-0.92; P = .024) during postoperative 12 to 24 hours was the only independent risk factor for stroke in the acute phase. Patients with stroke in the acute phase had higher serum lactate dehydrogenase levels at any point until postoperative 14 days. Patients with the HeartMate II device particularly showed a statistically significant negative relationship between cardiac output during postoperative 12 to 24 hours and serum lactate dehydrogenase levels at postoperative 14 days (r = -0.313, P = .03). Conclusions: Our study demonstrated that patients with perioperative lower cardiac output and higher lactate dehydrogenase level developed stroke in the acute phase after left ventricular assist device implantation. These results suggested that maintenance of sufficient left ventricular assist device flow is important in prevention of stroke, which may be related to subclinical pump thrombosis.
引用
收藏
页码:259 / +
页数:10
相关论文
共 18 条
[1]   Ambient hemolysis and activation of coagulation is different between Heart Mate II and Heart Ware left ventricular assist devices [J].
Birschmann, Ingvild ;
Dittrich, Marcus ;
Eller, Thomas ;
Wiegmann, Bettina ;
Reininger, Armin J. ;
Budde, Ulrich ;
Strueber, Martin .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (01) :80-87
[2]   Hemolysis: A harbinger of adverse outcome after Left ventricular assist device implant [J].
Cowger, Jennifer A. ;
Romano, Matthew A. ;
Shah, Palak ;
Shah, Neha ;
Mehta, Vivek ;
Haft, Jonathan W. ;
Aaronson, Keith D. ;
Pagani, Francis D. .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (01) :35-43
[3]   The Risk of Stroke on Left Ventricular Assist Device Support Steady Gains or Stalled Progress? [J].
DeVore, Adam D. ;
Stewart, Garrick C. .
JACC-HEART FAILURE, 2017, 5 (10) :712-714
[4]   Risk factors, mortality, and timing of ischemic and hemorrhagic stroke with left ventricular assist devices [J].
Frontera, Jennifer A. ;
Starling, Randall ;
Cho, Sung-Min ;
Nowacki, Amy S. ;
Uchino, Ken ;
Hussain, M. Shazam ;
Mountis, Maria ;
Moazami, Nader .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2017, 36 (06) :673-683
[5]   Seventh INTERMACS annual report: 15,000 patients and counting [J].
Kirklin, James K. ;
Naftel, David C. ;
Pagani, Francis D. ;
Kormos, Robert L. ;
Stevenson, Lynne W. ;
Blume, Elizabeth D. ;
Myers, Susan L. ;
Miller, Marissa A. ;
Baldwin, J. Timothy ;
Young, James B. .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (12) :1495-1504
[6]   Pump thrombosis in the Thoratec HeartMate II device: An update analysis of the INTERMACS Registry [J].
Kirklin, James K. ;
Naftel, David C. ;
Pagani, Francis D. ;
Kormos, Robert L. ;
Myers, Susan ;
Acker, Michael. A. ;
Rogers, Joseph ;
Slaughter, Mark S. ;
Stevenson, Lynne W. .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (12) :1515-1526
[7]   Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) analysis of pump thrombosis in the Heart Mate II left ventricular assist device [J].
Kirklin, James K. ;
Naftel, David C. ;
Kormos, Robert L. ;
Pagani, Francis D. ;
Myers, Susan L. ;
Stevenson, Lynne W. ;
Acker, Michael. A. ;
Goldstein, Daniel. L. ;
Silvestry, Scott C. ;
Milano, Carmelo A. ;
Baldwin, J. Timothy ;
Pinney, Sean ;
Rame, J. Eduardo ;
Miller, Marissa A. .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (01) :12-22
[8]   Lower body surface area is highly related to mortality due to stroke or systemic bleeding in patients receiving an axial flow blood pump as a left ventricular assist device [J].
Komoda, Takeshi ;
Drews, Thorsten ;
Hetzer, Roland ;
Lehmkuhl, Hans B. .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2013, 43 (05) :1036-1042
[9]   Blood Pressure Control in Continuous Flow Left Ventricular Assist Devices: Efficacy and Impact on Adverse Events [J].
Lampert, Brent C. ;
Eckert, Chad ;
Weaver, Stephanie ;
Scanlon, Ana ;
Lockard, Kathy ;
Allen, Carrie ;
Kunz, Nicole ;
Bermudez, Christian ;
Bhama, Jay K. ;
Shullo, Michael A. ;
Kormos, Robert L. ;
Dew, Mary Amanda ;
Teuteberg, Jeffrey J. .
ANNALS OF THORACIC SURGERY, 2014, 97 (01) :139-146
[10]   PREVENtion of HeartMate II Pump Thrombosis Through Clinical Management: The PREVENT multi-center study [J].
Maltais, Simon ;
Kilic, Ahmet ;
Nathan, Sriram ;
Keebler, Mary ;
Emani, Sitaramesh ;
Ransom, John ;
Katz, Jason N. ;
Sheridan, Brett ;
Brieke, Andreas ;
Egnaczyk, Gregory ;
Entwistle, John W., III ;
Adamson, Robert ;
Stulak, John ;
Uriel, Nir ;
O'Connell, John B. ;
Farrar, David J. ;
Sundareswaran, Kartik S. ;
Gregoric, Igor .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2017, 36 (01) :1-12