Removal characteristics of PCDD/Fs by the dual bag filter system of a fly ash treatment plant

被引:45
作者
Lin, Wen-Yinn [2 ]
Wang, Lin-Chi [1 ]
Wang, Ya-Fen [3 ]
Li, Hsing-Wang [4 ]
Chang-Chien, Guo-Ping [1 ]
机构
[1] Cheng Shiu Univ, Dept Chem & Mat Engn, Kaohsiung 833, Taiwan
[2] Natl Taipei Univ Technol, Inst Environm Engn & Management, Taipei 106, Taiwan
[3] Chung Yuan Christian Univ, Dept Bioenvironm Engn, Chungli 320, Taiwan
[4] Natl Cheng Kung Univ, Dept Environm Engn, Sustainable Environm Res Ctr, Tainan 70101, Taiwan
关键词
PCDD/Fs; dual bag filter; Waelz rotary-kiln; activated carbon injection; zinc recycling;
D O I
10.1016/j.jhazmat.2007.09.054
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this study, a dual bag filter system was established to decrease the concentration of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) in the stack flue gases of a fly ash treatment plant, which retained zinc from the fly ash of electric arc furnaces. Compared to the original single bag filter system with activated carbon injection (ACI) of 40 kg h(-1), the PCDD/F concentrations in the stack flue gas after the plant was equipped with the dual bag filter system dropped enormously from 3.38-7.73 ng I-TEQ N m(-3) to 0.03 ng I-TEQ N m(-3), and the total PCDD/F I-TEQ removal efficiency increased from 97.6% to 99.3% with ACI of 16 kg h(-1), that is, about 40% of the original AC usage. The AC utilization efficiency (0.560 mg I-TEQ absorbed kg ACI(-1)) of the dual bag filter system (AC: 16 kg h(-1)) was estimated about three times higher than that (0.192 mg I-TEQ absorbed kg ACI(-1)) of single bag filter system with ACI (40 kg h(-1)). The reason is that the particulate phase PCDD/Fs and some gas phase PCDD/Fs (captured by the recycled AC/ash mixture) were removed first by the first bag filter, and the rest of. the gas phase PCDD/Fs were able to be adsorbed more completely by the AC/ash mixture due to a lower fly ash load, and then were removed by the second bag filter. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:1015 / 1022
页数:8
相关论文
共 23 条
[1]   Improvements to the UK PCDD/F and PCB atmospheric emission inventory following an emissions measurement programme [J].
Alcock, RE ;
Gemmill, R ;
Jones, KC .
CHEMOSPHERE, 1999, 38 (04) :759-770
[2]   PCDD/Fs emissions inventory in the Lombardy Region: results and uncertainties [J].
Caserini, S ;
Monguzzi, AM .
CHEMOSPHERE, 2002, 48 (08) :779-786
[3]   Evaluation of the emission characteristics of PCDD/Fs from electric are furnaces [J].
Chang, MB ;
Huang, HC ;
Tsai, SS ;
Chi, KH ;
Chang-Chien, GP .
CHEMOSPHERE, 2006, 62 (11) :1761-1773
[4]  
CHANG MB, 2004, 3 I CIPEC HANGZH CHI
[5]   PCDD/F emissions and distributions in Waelz plant and ambient air during different operating stages [J].
Chi, Kai Hsien ;
Chang, Shu Hao ;
Chang, Moo Been .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2007, 41 (07) :2515-2522
[6]   Characteristics of PCDD/F distributions in vapor and solid phases and emissions from the Waelz process [J].
Chi, KH ;
Chang, SH ;
Chang, MB .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2006, 40 (06) :1770-1775
[7]   An overview on the current processes for the recycling of batteries [J].
Espinosa, DCR ;
Bernardes, AM ;
Tenório, JAS .
JOURNAL OF POWER SOURCES, 2004, 135 (1-2) :311-319
[8]   The formation and emission of dioxins in large scale thermal processes [J].
Everaert, K ;
Baeyens, J .
CHEMOSPHERE, 2002, 46 (03) :439-448
[9]   ON THE MECHANISMS OF DIOXIN FORMATION IN COMBUSTION PROCESSES [J].
HUANG, H ;
BUEKENS, A .
CHEMOSPHERE, 1995, 31 (09) :4099-4117
[10]  
*JAP MIN ENV, 2002, ENV MON REP PERS ORG, P40