Assessment of Indoor Air Quality and Users Perception of a Renovated Office Building in Manchester

被引:20
作者
Alomirah, Haya Fahad [1 ,2 ]
Moda, Haruna Musa [2 ]
机构
[1] Coll Hlth Sci, POB 1983, Safat 13020, Kuwait
[2] Manchester Metropolitan Univ, Dept Hlth Profess, Manchester M15 6BG, Lancs, England
关键词
sick building syndrome; indoor air quality; post occupancy evaluation; questionnaire survey; instrumentation; THERMAL COMFORT; PSYCHOSOCIAL FACTORS; GENDER-DIFFERENCES; HEALTH; PRODUCTIVITY; ENVIRONMENT; SYMPTOMS; DAMPNESS;
D O I
10.3390/ijerph17061972
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Building renovations can adversely affect building occupants through the release of biological contaminants, gases and particulates. In this study, the research aim was to monitor the air quality of a renovated building and assess the impact of sick building syndrome (SBS) on the occupants. Post occupancy monitoring of the building was carried out after two months occupancy for the following environmental parameters: airborne microflora using an air sampler (SAS super 180) and a hand-held monitoring device (Graywolf advance sense IQ-610) to measure total volatile organic compounds (TVOC), CO2, CO and temperature and relative humidity in each office environment. In addition, an online (Qualtrics) structured questionnaire was used to assess occupants' perceptions of the indoor environment. Results of the airborne flora showed 833 cfu/m(3) recovered on a Malt Extract Agar (MEA) plate in the morning and 1213 cfu/m(3) in the afternoon. A similar result was noticed on a Plate Count Agar (PCA) plate during the morning period (731 cfu/m(3)) and afternoon (1358 cfu/m(3)). Results of TVOC monitored over one week showed that the first two days of monitoring had a high reading that peaked at 10,837 ppb and that the CO2 concentration during that period was 1163 ppm. Online questionnaire analysis indicates that a majority of the staff who took part in the survey experienced some form of health abnormality, including headache, shortness of breath, itchy eyes/ears, loss of concentration and so on, especially in the first few weeks of returning to the office. The results from the study indicate that a large proportion (41%) of the respondents experienced thermal discomfort as a result of varying room temperature during their working hours. A high number of female participants experienced some form of SBS as compared to their male counterparts. The study findings show a direct relationship between high airborne mold counts, TVOC and adverse staff health perception of the building. The study raised a number of opportunities for estate managers to improve building performance based on occupants' preferences.
引用
收藏
页数:9
相关论文
共 33 条
[1]   Occupant productivity and office indoor environment quality: A review of the literature [J].
Al Horr, Yousef ;
Arif, Mohammed ;
Kaushik, Amit ;
Mazroei, Ahmed ;
Katafygiotou, Martha ;
Elsarrag, Esam .
BUILDING AND ENVIRONMENT, 2016, 105 :369-389
[2]  
[Anonymous], 2014, FULL REP SICKN ABS L
[3]  
[Anonymous], 2002, Introduction to Food-And Airborne Fungi
[4]   COMPARISON BETWEEN MALE AND FEMALE SUBJECTIVE ESTIMATES OF THERMAL EFFECTS AND SENSATIONS [J].
BESHIR, MY ;
RAMSEY, JD .
APPLIED ERGONOMICS, 1981, 12 (01) :29-33
[5]   Why do women suffer from sick building syndrome more often than men? Subjective higher sensitivity versus objective causes [J].
Brasche, S ;
Bullinger, M ;
Morfeld, M ;
Gebhardt, HJ ;
Bischof, W .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 2001, 11 (04) :217-222
[6]   The medical effects of mold exposure [J].
Bush, RK ;
Portnoy, JM ;
Saxon, A ;
Terr, AI ;
Wood, RA .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2006, 117 (02) :326-333
[7]   Human health and thermal comfort of office workers in Singapore [J].
Chen, Ailu ;
Chang, Victor W. -C. .
BUILDING AND ENVIRONMENT, 2012, 58 :172-178
[8]   Indoor dampness and mould health effects - ongoing questions on microbial exposures and allergic versus nonallergic mechanisms [J].
Cox-Ganser, J. M. .
CLINICAL AND EXPERIMENTAL ALLERGY, 2015, 45 (10) :1478-1482
[9]   Psychosocial factors and the ''sick building-syndrome''. A case-referent study [J].
Eriksson, N ;
Hoog, J ;
Stenberg, B ;
Sundell, J .
INDOOR AIR, 1996, 6 (02) :101-110
[10]   Literature survey on how different factors influence human comfort in indoor environments [J].