Design of an Optimized Fractional High Order Differential Feedback Controller for Load Frequency Control of a Multi-Area Multi-Source Power System With Nonlinearity

被引:49
|
作者
Sahin, Erdinc [1 ]
机构
[1] Karadeniz Tech Univ, Dept Energy Syst Engn, TR-61830 Trabzon, Turkey
来源
IEEE ACCESS | 2020年 / 8卷
关键词
Load frequency control; governor dead band; generation rate constraint; random load pattern; fractional calculus; fractional high order differential feedback controller; particle swarm optimization; robustness and transient response analysis; AUTOMATIC-GENERATION CONTROL; INTEGRAL DERIVATIVE CONTROLLER; FUZZY-PID CONTROLLER; THERMAL SYSTEM; HARMONY SEARCH; ALGORITHM; FILTER;
D O I
10.1109/ACCESS.2020.2966261
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Load frequency control (LFC) is one of the essential process in interconnected power systems. To provide high quality, reliable and stable electrical power, designed controller should perform satisfactorily, i.e. suppress area frequency and tie-line power deviations. Within this scope, in this study, a high order differential feedback controller (HODFC) and a developed fractional high order differential feedback controller (FHODFC) are proposed for LFC problem in multi-area power systems for the first time. The gains of the HODFC and FHODFC are optimally tuned by particle swarm optimization (PSO) algorithm aiming to minimize integral of time weighted absolute error (ITAE) performance index. The superiority of the developed FHODFC are verified by comparing reported controller structures in the recent state-of-the-art literature and HODFC for two identical non-reheat thermal power system and two-area multi-source power system consisting of gas, thermal and hydro generation units with/without consideration of HVDC link. To test the robustness of the designed controllers, varying system parameters and loading conditions are investigated. The governor dead band (GDB) and generation rate constraint (GRC) limitations are also considered for the system under study to examine non-linearity handling success of the proposed controllers. Performance results indicate that the developed FHODFC provides better dynamic response and robustness than other published techniques under nonlinearities, random load pattern, and variations in system parameters and loading conditions.
引用
收藏
页码:12327 / 12342
页数:16
相关论文
共 50 条
  • [1] Load Frequency Control of Multi-source System by Jaya Optimized Fractional Order PID Controller
    Mishra, Saroj Kumar
    Pati, Subhranshu Sekhar
    2020 7TH IEEE INTERNATIONAL CONFERENCE ON SMART STRUCTURES AND SYSTEMS (ICSSS 2020), 2020, : 287 - 291
  • [2] LFOPI controller: a fractional order PI controller based load frequency control in two area multi-source interconnected power system
    Sharma, Deepesh
    Yadav, Naresh Kumar
    DATA TECHNOLOGIES AND APPLICATIONS, 2020, 54 (03) : 323 - 342
  • [3] Combined Voltage and Frequency Control of a Multi-Area Multi-Source System Using SFLA Optimized TID Controller
    Babu, Naladi Ram
    Sahu, Devesh Kumar
    Saikia, Lalit Chandra
    Ramoji, Satish Kumar
    2019 IEEE 16TH INDIA COUNCIL INTERNATIONAL CONFERENCE (IEEE INDICON 2019), 2019,
  • [4] Design of an ORBP-based fractional order controller for load frequency control in a multi-area power system with integration of RES
    Dinesh, T.
    Manjula, M.
    PRZEGLAD ELEKTROTECHNICZNY, 2024, 100 (09): : 100 - 105
  • [5] Load Frequency Control of a Multi-area, Multi-source System Using Firefly Algorithm Optimized F2DOFIDD Controller
    Sarma, Upasana
    Saikia, Lalit Chandra
    Saha, Arindita
    Dash, Puja
    PROCEEDINGS OF THE 2016 IEEE REGION 10 CONFERENCE (TENCON), 2016, : 1475 - 1479
  • [6] An Optimized Hybrid Fractional Order Controller for Frequency Regulation in Multi-Area Power Systems
    Mohamed, Emad A.
    Ahmed, Emad M.
    Elmelegi, Ahmed
    Aly, Mokhtar
    Elbaksawi, Osama
    Mohamed, Al-Attar Ali
    IEEE ACCESS, 2020, 8 : 213899 - 213915
  • [7] Quasi oppositional harmony search algorithm based controller tuning for load frequency control of multi-source multi-area power system
    Shankar, G.
    Mukherjee, V.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2016, 75 : 289 - 302
  • [8] An Optimal Controller for Load Frequency Control in Multi-Area Deregulated power system
    Sina, Alireza
    Kaur, Damanjeet
    JOURNAL OF ELECTRICAL SYSTEMS, 2019, 15 (01) : 142 - 158
  • [9] Combined Voltage and Frequency control of a Multi-Area Multi-Source Power System using CFOPI-TIDN Controller
    Ramoji, Satish Kumar
    Saikia, Lalit Chandra
    Dekaraja, Biswanath
    Behera, Manoja Kumar
    Babu, Naladi Ram
    Bhagat, Sanjeev Kumar
    2021 INTERNATIONAL CONFERENCE ON COMPUTATIONAL PERFORMANCE EVALUATION (COMPE-2021), 2021, : 761 - 766
  • [10] Analysis of tilt integral derivative controller-based automatic load frequency control of multi-area multi-source system
    Boddepalli M.K.
    Navuri P.K.
    International Journal of Power Electronics, 2022, 15 (3-4) : 418 - 442