Improvement of image quality in PET using post-reconstruction hybrid spatial-frequency domain filtering

被引:35
作者
Arabi, Hossein [1 ]
Zaidi, Habib [1 ,2 ,3 ,4 ]
机构
[1] Geneva Univ Hosp, Dept Med Imaging, Div Nucl Med & Mol Imaging, CH-1211 Geneva, Switzerland
[2] Univ Geneva, Geneva Univ Neuroctr, CH-1205 Geneva, Switzerland
[3] Univ Groningen, Univ Med Ctr Groningen, Dept Nucl Med & Mol Imaging, NL-9700 RB Groningen, Netherlands
[4] Univ Southern Denmark, Dept Nucl Med, DK-500 Odense, Denmark
基金
瑞士国家科学基金会;
关键词
PET; image quality; non-local means; curvelet transform; filtering; EMISSION-TOMOGRAPHY; COMPUTED-TOMOGRAPHY; MAXIMUM-LIKELIHOOD; NONLOCAL MEANS; DYNAMIC PET; RECONSTRUCTION; WAVELET; NOISE; ALGORITHMS; RESOLUTION;
D O I
10.1088/1361-6560/aae573
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
PET images commonly suffer from the high noise level and poor signal-to-noise ratio (SNR), thus adversely impacting lesion detectability and quantitative accuracy. In this work, a novel hybrid dual-domain PET denoising approach is proposed, which combines the advantages of both spatial and transform domain filtering to preserve image textures while minimizing quantification uncertainty. Spatial domain denoising techniques excel at preserving high-contrast patterns compared to transform domain filters, which perform well in recovering low-contrast details normally smoothed out by spatial domain filters. For spatial domain filtering, the non-local mean algorithm was chosen owing to its performance in denoising high-contrast features whereas multi-scale curvelet denoising was exploited for the transform domain owing to its capability to recover small details. The proposed hybrid method was compared to conventional post-reconstruction Gaussian and edge preserving bilateral filters. Computer simulations of a thorax phantom containing three small lesions, experimental measurements using the Jaszczak phantom and clinical whole-body PET/CT studies were used to evaluate the performance of the proposed PET denoising technique. The proposed hybrid filter increased the SNR from 8.0 (non-filtered PET image) to 39.3 for small lesions in the computerized thorax phantom, while Gaussian and bilateral filtering led to SNRs of 23.3 and 24.4, respectively. For the experimental Jaszczak phantom, the contrast-to-noise ratio (CNR) improved from 10.84 when using Gaussian smoothing to 14.02 and 19.39 using the bilateral and the proposed hybrid filters, respectively. The clinical studies further demonstrated the superior performance of the hybrid method, yielding a quantification change (the original noisy OSEM image was used as reference in the absence of ground truth) in malignant lesions of -2.4% compared to -11.9% and -6.6% achieved using Gaussian and bilateral filters, respectively. In some cases, the visual difference between the bilateral and hybrid filtered images is not substantial; however the improved CNR score from 11.3 by OSEM to 17.1 and 21.8 by bilateral to the hybrid filtering, respectively, demonstrates the overall gain achieved by the hybrid approach. The proposed hybrid algorithm improved the contrast, SNR and quantitative accuracy compared to Gaussian and bilateral approaches, and can be utilized as an alternative post-reconstruction filter in clinical PET/CT imaging.
引用
收藏
页数:17
相关论文
共 40 条
[1]  
Boashash B., 2015, TIME FREQUENCY SIGNA
[2]  
Boellaard R, 2001, J NUCL MED, V42, P808
[3]   Efficient nonlocal means for denoising of textural patterns [J].
Brox, Thomas ;
Kleinschmidt, Oliver ;
Cremers, Daniel .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 2008, 17 (07) :1083-1092
[4]   A non-local algorithm for image denoising [J].
Buades, A ;
Coll, B ;
Morel, JM .
2005 IEEE COMPUTER SOCIETY CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION, VOL 2, PROCEEDINGS, 2005, :60-65
[5]   Postreconstruction Nonlocal Means Filtering of Whole-Body PET With an Anatomical Prior [J].
Chan, Chung ;
Fulton, Roger ;
Barnett, Robert ;
Feng, David Dagan ;
Meikle, Steven .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (03) :636-650
[6]   Regularized image reconstruction with an anatomically adaptive prior for positron emission tomography [J].
Chan, Chung ;
Fulton, Roger ;
Feng, David Dagan ;
Meikle, Steven .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (24) :7379-7400
[7]   A comparison of wavelet, ridgelet, and curvelet-based texture classification algorithms in computed tomography [J].
Dettori, Lucia ;
Semler, Lindsay .
COMPUTERS IN BIOLOGY AND MEDICINE, 2007, 37 (04) :486-498
[8]   IDEAL SPATIAL ADAPTATION BY WAVELET SHRINKAGE [J].
DONOHO, DL ;
JOHNSTONE, IM .
BIOMETRIKA, 1994, 81 (03) :425-455
[9]   Sparse directional image representations using the discrete shearlet transform [J].
Easley, Glenn ;
Labate, Demetrio ;
Lim, Wang-Q .
APPLIED AND COMPUTATIONAL HARMONIC ANALYSIS, 2008, 25 (01) :25-46
[10]   On the origin of the bilateral filter and ways to improve it [J].
Elad, M .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 2002, 11 (10) :1141-1151