Removal of volar plate after open reduction internal fixation of distal radius fractures : clinical and radiographic analysis

被引:0
作者
Shlaifer, Amir [1 ]
Atlan, Franck [1 ]
Kadar, Assaf [1 ]
Dolkart, Oleg [1 ]
Rosenblatt, Yishai [1 ]
Pritsch, Tamir [1 ]
机构
[1] Tel Aviv Univ, Sackler Fac Med, Tel Aviv Sourasky Med Ctr, Div Orthopaed Surg, Tel Aviv, Israel
来源
ACTA ORTHOPAEDICA BELGICA | 2021年 / 87卷 / ES1期
关键词
distal radius fracture; volar plate; implant removal; implant prominence; POLLICIS LONGUS RUPTURE; HARDWARE REMOVAL; LOCKING SCREW; UNITED-STATES; COMPLICATIONS; EPIDEMIOLOGY; TENDON; LENGTH;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The operative treatment of distal radius fractures had evolved over the years. In the last two decades anatomic locking plates were introduced and are increasingly being used for this indication becoming the most common surgical fixation for distal radius fractures. This study investigated how often plate removal is related to preventable reasons such as plate and screw positioning, screw length, and quality of reduction. All patients who underwent volar plate removal in our institution between the years 2006-2014 were included in this study. Patients' charts were retrospectively reviewed, and preoperative radiographs were analyzed including plate to volar rim distance (PVR), plate to critical line distance (PCR), Soong classification, implant position, and screw prominence. A total of 50 patients (26 males, 24 females) were identified. Patients with subjective feeling of prominent implant were found to be younger than the rest of the cohort. In addition, this complaint was associated with ulnar prominence of the proximal part of the plate due to malposition on the coronal plane. Extensor tendon irritation was associated with prominence of the proximal screws. Only one case was associated with flexor tendon irritation and there was no association to the Soong grade or PCL and PVR measurements. We believe that good fracture reduction, correct plate positioning, and appropriate screw location and length, can largely limit the need for volar plate removal.
引用
收藏
页码:103 / 110
页数:8
相关论文
共 50 条
[41]   Distal radius nonunion after volar locking plate fixation of a distal radius fracture: a case report [J].
Shinohara, Takaaki ;
Hirata, Hitoshi .
NAGOYA JOURNAL OF MEDICAL SCIENCE, 2017, 79 (04) :551-557
[42]   Open reduction and internal fixation of distal radius extension fractures in women over 60 years of age with the dorsal radius plate (π-plate) [J].
Keller, M. ;
Steiger, R. .
HANDCHIRURGIE MIKROCHIRURGIE PLASTISCHE CHIRURGIE, 2006, 38 (02) :82-89
[43]   Incidence of Complications following Volar Locking Plate Fixation of Distal Radius Fractures: An Analysis of 647 Cases [J].
DeGeorge, Brent R., Jr. ;
Brogan, David M. ;
Becker, Hillary A. ;
Shin, Alexander Y. .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2020, 145 (04) :969-976
[44]   Clinical and Radiologic Outcomes of Volar Plate Fixation in AO Type C Distal Radius Fractures [J].
Senel, Ahmet ;
Ozturkmen, Yusuf ;
Akman, Yunus Emre ;
Sukur, Erhan ;
Unkar, Ethem Ayhan .
ISTANBUL MEDICAL JOURNAL, 2018, 19 (02) :119-123
[45]   Is Immobilization Necessary After Open Reduction and Internal Fixation of Distal Radius Fractures? A Meta-Analysis of Randomized Controlled Trials [J].
Daher, Mohammad ;
Casey, Jack C. ;
Helou, Pierre ;
Daniels, Alan H. ;
Gil, Joseph A. .
HAND-AMERICAN ASSOCIATION FOR HAND SURGERY, 2025,
[46]   Radiographic Incidence and Functional Outcomes of Distal Radius Fractures Undergoing Volar Plate Fixation With Concomitant Scapholunate Widening: A Prospective Analysis [J].
Wang, William L. ;
Abboudi, Jack ;
Gallant, Gregory ;
Jones, Christopher ;
Kirkpatrick, William ;
Kwok, Moody ;
Liss, Frederic ;
Takei, T. Robert ;
Wang, Mark ;
Ilyas, Asif M. .
HAND-AMERICAN ASSOCIATION FOR HAND SURGERY, 2022, 17 (02) :326-330
[47]   Percutaneous pinning versus volar locking plate internal fixation for unstable distal radius fractures: a meta-analysis [J].
Peng, Fei ;
Liu, Yuan-xiang ;
Wan, Zhen-yu .
JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2018, 43 (02) :158-167
[48]   The relationship between plate prominence and need for removal after volar plate osteosynthesis of distal radius fractures [J].
Tegels, Juul J. W. ;
Theunissen, Jarn E. M. ;
de Loos, Erik R. ;
Meesters, Berry ;
Boonen, Bert ;
van Vugt, Raoul .
EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2023, 49 (05) :2105-2111
[49]   Minimising the risk of extensor pollicis longus rupture following volar plate fixation of distal radius fractures: a cadaveric study [J].
Perry, D. C. ;
Machin, D. M. G. ;
Casaletto, J. A. ;
Brown, D. J. .
ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2011, 93 (01) :57-60
[50]   Removal of Locked Volar Plates After Distal Radius Fractures [J].
Gyuricza, Cassie ;
Carlson, Michelle Gerwin ;
Weiland, Andrew J. ;
Wolfe, Scott W. ;
Hotchkiss, Robert N. ;
Daluiski, Aaron .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2011, 36A (06) :982-985