Removal of volar plate after open reduction internal fixation of distal radius fractures : clinical and radiographic analysis

被引:0
|
作者
Shlaifer, Amir [1 ]
Atlan, Franck [1 ]
Kadar, Assaf [1 ]
Dolkart, Oleg [1 ]
Rosenblatt, Yishai [1 ]
Pritsch, Tamir [1 ]
机构
[1] Tel Aviv Univ, Sackler Fac Med, Tel Aviv Sourasky Med Ctr, Div Orthopaed Surg, Tel Aviv, Israel
来源
ACTA ORTHOPAEDICA BELGICA | 2021年 / 87卷 / ES1期
关键词
distal radius fracture; volar plate; implant removal; implant prominence; POLLICIS LONGUS RUPTURE; HARDWARE REMOVAL; LOCKING SCREW; UNITED-STATES; COMPLICATIONS; EPIDEMIOLOGY; TENDON; LENGTH;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The operative treatment of distal radius fractures had evolved over the years. In the last two decades anatomic locking plates were introduced and are increasingly being used for this indication becoming the most common surgical fixation for distal radius fractures. This study investigated how often plate removal is related to preventable reasons such as plate and screw positioning, screw length, and quality of reduction. All patients who underwent volar plate removal in our institution between the years 2006-2014 were included in this study. Patients' charts were retrospectively reviewed, and preoperative radiographs were analyzed including plate to volar rim distance (PVR), plate to critical line distance (PCR), Soong classification, implant position, and screw prominence. A total of 50 patients (26 males, 24 females) were identified. Patients with subjective feeling of prominent implant were found to be younger than the rest of the cohort. In addition, this complaint was associated with ulnar prominence of the proximal part of the plate due to malposition on the coronal plane. Extensor tendon irritation was associated with prominence of the proximal screws. Only one case was associated with flexor tendon irritation and there was no association to the Soong grade or PCL and PVR measurements. We believe that good fracture reduction, correct plate positioning, and appropriate screw location and length, can largely limit the need for volar plate removal.
引用
收藏
页码:103 / 110
页数:8
相关论文
共 50 条
  • [1] Risk of Volar Locking Plate Removal After Distal Radius Fractures: Time-to-Event Analysis
    Holc, Fernando
    Victorica, Pedro Bronenberg
    Avanzi, Rocio
    Huespe, Ivan A.
    De Carli, Pablo
    Boretto, Jorge G.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2023, 48 (10): : 1011 - 1017
  • [2] Volar plate fixation of distal radius fractures
    Demirbas, Emrah Riza
    Ugras, Ali Akin
    Kaya, Ibrahim
    Sungur, Ibrahim
    Kural, Cemal
    Cetinus, Ercan
    ULUSAL TRAVMA VE ACIL CERRAHI DERGISI-TURKISH JOURNAL OF TRAUMA & EMERGENCY SURGERY, 2012, 18 (02): : 162 - 166
  • [3] Radiographic assessment of ligamentous injuries in distal radius fractures after open reduction and internal fixation
    Naran S.
    Zaulan Y.
    Shakir S.
    Gilula L.A.
    Werner F.W.
    Wollstein R.
    European Journal of Orthopaedic Surgery & Traumatology, 2014, 24 (7) : 1151 - 1154
  • [4] Biomechanical Properties of Volar Hybrid and Locked Plate Fixation in Distal Radius Fractures
    Sokol, Shima C.
    Amanatullah, Derek F.
    Curtiss, Shane
    Szabo, Robert M.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2011, 36A (04): : 591 - 597
  • [5] Flexor Pollicis Longus Dysfunction After Volar Plate Fixation of Distal Radius Fractures
    Chilelli, Brian J.
    Patel, Ronak M.
    Kalainov, David M.
    Peng, Jie
    Zhang, Li-Qun
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2013, 38A (09): : 1691 - 1697
  • [6] Use of Volar Locking Plate Versus Intramedullary Nailing for Fixation of Distal Radius Fractures: A Retrospective Analysis of Clinical and Radiographic Outcomes
    Calbiyik, Murat
    Ipek, Deniz
    MEDICAL SCIENCE MONITOR, 2018, 24 : 602 - 613
  • [7] Teardrop Alignment Changes After Volar Locking Plate Fixation of Distal Radius Fractures With Volar Ulnar Fragments
    McCarty, Justin C.
    Cross, Rachel E.
    Laane, Charlotte L. E.
    Hoftiezer, Yannick Albert J.
    Gavagnin, Aquiles
    Regazzoni, Pietro
    Dell'Oca, Alberto Fernandez
    Jupiter, Jesse B.
    Bhashyam, Abhiram R.
    HAND-AMERICAN ASSOCIATION FOR HAND SURGERY, 2024,
  • [8] Complications after volar locking plate fixation of distal radius fractures
    Johnson, N. A.
    Cutler, L.
    Dias, J. J.
    Ullah, A. S.
    Wildin, C. J.
    Bhowal, B.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2014, 45 (03): : 528 - 533
  • [9] Complications of Volar Plate Fixation for Managing Distal Radius Fractures
    Berglund, Lisa M.
    Messer, Terry M.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2009, 17 (06) : 369 - 377
  • [10] Volar Plate Fixation for the Treatment of Distal Radius Fractures: Analysis of Adverse Events
    Tarallo, Luigi
    Mugnai, Raffaele
    Zambianchi, Francesco
    Adani, Roberto
    Catani, Fabio
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2013, 27 (12) : 740 - 745