External fixation of the pelvic ring - An experimental study on the role of pin diameter, pin position, and parasymphyseal fixator pins

被引:24
作者
Ponsen, Kees-Jan [1 ]
Joosse, Pieter
van Dijke, Gilbert A. Hoek
Snijders, Chris J.
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Surg, Trauma Unit, NL-1105 AZ Amsterdam, Netherlands
[2] Erasmus Univ, Fac Med, Dept Biomed Phys & Technol, NL-3000 DR Rotterdam, Netherlands
关键词
D O I
10.1080/17453670710014347
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background The mechanical properties of current external fixator systems for unstable (type C) pelvic ring fractures are inferior to internal fixation, and are not optimal for definitive treatment. We explored methods to increase stability of external fixator constructs. Methods An experimental model was used for load tests. The same pelvic fixator was used while different pin diameters, pin positions, and modes of pubic symphysis fixation were tested. Results Changing of the pin diameter of the unthreaded part from 6 to 8 mm resulted in an increase in stiffness of 20%. An increase in stiffness by a factor of 1.9 was found by placing a pin on the iliac crest and one supra-acetabular. An additional increase by a factor of 3.6 was obtained by adding pubic symphysis plate fixation. Parasymphyseal pin fixation instead reduced stiffness, but not so much as when parasymphyseal pins were connected to the external fixator of the pelvic ring. The final configuration was at least 6 times stiffer than the initial configuration. Interpretation The new concept of parasymphyseal pin fixation connected to an external fixator of the pelvic ring produces a considerable increase in stability for the treatment of type C pelvic ring injuries, as does an increase in pin diameter and alternative pin positioning.
引用
收藏
页码:648 / 653
页数:6
相关论文
共 29 条
[1]  
Abdel-Aziz Y., 1971, ASP UI S CLOS RANG P
[2]  
BEHRENS F, 1989, CLIN ORTHOP RELAT R, P15
[3]   Strategies for surgical treatment of multiple trauma including pelvic fracture. Review of the literature [J].
Burkhardt, M ;
Culemann, U ;
Seekamp, A ;
Pohlemann, T .
UNFALLCHIRURG, 2005, 108 (10) :812-+
[4]  
Culemann U, 2000, UNFALLCHIRURG, V103, P965, DOI 10.1007/s001130050654
[5]  
DUBBEL H, 1986, TASCHENBUCH MACHINEN
[6]   TORSIONAL STRENGTH REDUCTION DUE TO CORTICAL DEFECTS IN BONE [J].
EDGERTON, BC ;
AN, KN ;
MORREY, BF .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1990, 8 (06) :851-855
[7]  
Gansslen A, 1996, INJURY S1, V27, pS20
[8]  
Garbuglia A, 1998, Chir Ital, V50, P61
[9]   UPGRADING OF EFFICIENCY IN THE TRACKING OF BODY MARKERS WITH VIDEO TECHNIQUES [J].
KEEMINK, CJ ;
VANDIJKE, GAH ;
SNIJDERS, CJ .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1991, 29 (01) :70-74
[10]   Effect of pin location on stability of pelvic external fixation [J].
Kim, WY ;
Hearn, TC ;
Seleem, O ;
Mahalingam, E ;
Stephen, D ;
Tile, M .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1999, (361) :237-244