Automated Monitoring of Magnet Quality for Permanent-Magnet Synchronous Motors at Standstill

被引:69
|
作者
Hong, Jongman [1 ]
Hyun, Doosoo [1 ]
Lee, Sang Bin [1 ]
Yoo, Ji-Yoon [1 ]
Lee, Kwang-Woon [2 ]
机构
[1] Korea Univ, Dept Elect Engn, Seoul 136713, South Korea
[2] Mokpo Natl Maritime Univ, Div Marine Elect & Commun, Mokpo 530729, South Korea
基金
新加坡国家研究基金会;
关键词
AC machine; condition monitoring; demagnetization; diagnostics; inverter; NdFeB magnet; offline testing; permanent magnet (PM); pulsating magnetic field; synchronous motor; ROTOR-POSITION; SPEED;
D O I
10.1109/TIA.2010.2049811
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Demagnetization of permanent magnets (PMs) used in synchronous motors can occur due to a combination of thermal, electrical, and/or environmental operating stresses. Since PM demagnetization results in degradation of motor performance, efficiency, and reliability, it is important to monitor the quality of PMs regularly. However, there are many limitations to the offline and online methods currently used for magnet quality assessment. In this paper, a new inverter-embedded technique for automated monitoring of magnet quality for permanent-magnet synchronous motors (PMSMs), which overcomes the limitations of existing techniques, is proposed. The main concept is to use the inverter to perform a standstill test whenever the motor is stopped to detect local or uniform PM demagnetization. The machine is excited with a pulsating field at different angular positions, and the change in the current peaks caused by the change in the degree of magnetic saturation due to demagnetization is observed. An experimental study on a 10-hp PMSM verifies that local and uniform PM demagnetizations can be detected with high sensitivity.
引用
收藏
页码:1397 / 1405
页数:9
相关论文
共 50 条
  • [1] Automated Monitoring of Magnet Quality for Permanent Magnet Synchronous Motors at Standstill
    Hong, Jongman
    Hyun, Doosoo
    Lee, Sang Bin
    Yoo, Jiyoon
    Lee, Kwangwoon
    2009 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION, VOLS 1-6, 2009, : 2246 - +
  • [2] Monitoring the thermal condition of permanent-magnet synchronous motors
    Milanfar, P
    Lang, JH
    IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 1996, 32 (04) : 1421 - 1429
  • [3] ANALYSIS OF PERMANENT-MAGNET SYNCHRONOUS MOTORS
    CONSOLI, A
    RACITI, A
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1991, 27 (02) : 350 - 354
  • [4] ANALYSIS OF PERMANENT-MAGNET SYNCHRONOUS MOTORS
    CONSOLI, A
    RACITI, A
    CONFERENCE RECORD OF THE 1989 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING, PTS 1-2, 1989, : 63 - 68
  • [5] MODELING OF PERMANENT-MAGNET SYNCHRONOUS MOTORS
    SEBASTIAN, T
    SLEMON, GR
    RAHMAN, MA
    IEEE TRANSACTIONS ON MAGNETICS, 1986, 22 (05) : 1069 - 1071
  • [6] HYBRID PERMANENT-MAGNET SYNCHRONOUS MOTORS
    BINNS, KJ
    BARNARD, WR
    JABBAR, MA
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1978, 125 (03): : 203 - 208
  • [7] CORE LOSS IN BURIED MAGNET PERMANENT-MAGNET SYNCHRONOUS MOTORS
    SCHIFERL, R
    LIPO, TA
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 1989, 4 (02) : 279 - 284
  • [8] Optimum design of magnet shape in permanent-magnet synchronous motors
    Li, Y
    Zou, JB
    Lu, YP
    IEEE TRANSACTIONS ON MAGNETICS, 2003, 39 (06) : 3523 - 3526
  • [9] Nonlinear model of permanent-magnet synchronous motors
    Lian, Jun-Qiang
    Xie, Shun-Yi
    Jian, Wang
    Hu, Ping
    International Journal of Digital Content Technology and its Applications, 2012, 6 (07) : 119 - 126
  • [10] Vector control of permanent-magnet synchronous motors
    Voronin S.G.
    Kurnosov D.A.
    Kul'Mukhametova A.S.
    Russian Electrical Engineering, 2013, 84 (10) : 581 - 585