Comparison between Weightbearing-CT semiautomatic and manual measurements in Hallux Valgus

被引:29
作者
de Carvalho, Kepler Alencar Mendes [1 ,4 ]
Walt, Jennifer Sander [1 ]
Ehret, Amanda [1 ]
Tazegul, Tutku Erim [1 ]
Dibbern, Kevin [1 ]
Mansur, Nacime Salomao Barbachan [1 ,2 ]
Lalevee, Matthieu [1 ,3 ]
Netto, Cesar de Cesar [1 ]
机构
[1] Univ Iowa, Carver Coll Med, Dept Orthoped & Rehabil, Iowa City, IA USA
[2] Univ Fed Sao Paulo, Dept Orthoped & Traumatol, Sao Paulo, SP, Brazil
[3] Rouen Univ Hosp, Dept Orthoped Surg, Rouen, France
[4] Univ Iowa, Carver Coll Med, Dept Orthoped & Rehabil, 200 Hawkins Dr,John PappaJohn Pavill JPP, Iowa City, IA 52242 USA
关键词
Hallux Valgus; Deformity; WBCT; Measurements; Three-dimensional; Automatic; Manual; Segmentation; Intermetatarsal; Angles; COMPUTED-TOMOGRAPHY; FOOT; DEMOGRAPHICS; ETIOLOGY; SCAN; BONE;
D O I
10.1016/j.fas.2022.02.014
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Radiographic measurements are an essential tool to determine the appropriate surgical treatment and outcome for Hallux Valgus (HV). HV deformity is best evaluated by weight-bearing computed tomography (WBCT). The objective was (1) to assess the reliability of WBCT computer-assisted semi-automatic imaging measurements in HV, (2) to compare semi-automatic with manual measurements in the setting of an HV, and (3) to compare semi-automatic measurements between HV and control group. Methods: In this retrospective IRB (ID# 201904825) approved study, we assessed patients with hallux valgus deformity. The sample size calculation was based on the hallux valgus angle (HVA). Thus to obtain the 0.8 power, including 26 feet with HV in this study, was necessary. Our control group consisted of 19 feet from 19 patients without HV. Raw multiplanar data was evaluated using software CubeVue (R). In the axial plane, hallux valgus angle (HVA), intermetatarsal angle (IMA), and interphalangeal angle (IPA) were measured. The semiautomatic 3D measurements were performed using the Bonelogic (R) Software. Inter-rater reliabilities were performed using ICC. Agreement between methods was tested using the Bland-Altman plots. The difference between Patologic and Control cases using semi-automatic measurements was assessed with the Wilcoxon signed-rank test. Alpha risk was set to 5% (alpha = 0.05). P <= 0.05 were considered significant. Results: Reliabilities utilizing ICC were over 0.80 for WBCT manual measurements and WBCT semi-automatic readings. Inter and intraobserver agreement for Manual and Semi-automatic WBCT measurements demonstrated excellent reliability. Conclusions: Semi-automatic measurements are reproducible and comparable to measurements performed manually. The software differentiated pathological from non-pathological conditions when subjected to semi-automatic measurements. The development of advanced semi-automatic segmentation software with minimal user intervention is essential for the establishment of big data and can be integrated into clinical practice, facilitating decision-making. (c) 2022 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:518 / 525
页数:8
相关论文
共 48 条
[1]   MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES [J].
ALTMAN, DG ;
BLAND, JM .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) :307-317
[2]  
[Anonymous], 2005, JMP BASIC UNIVARIATE
[3]   Subtalar Joint Axis in Patients With Symptomatic Peritalar Subluxation Compared to Normal Controls [J].
Apostle, Kelly L. ;
Coleman, Nathan W. ;
Sangeorzan, Bruce J. .
FOOT & ANKLE INTERNATIONAL, 2014, 35 (11) :1153-1158
[4]   Association Between Hindfoot Alignment and First Metatarsal Rotation [J].
Bakshi, Neil ;
Steadman, Jesse ;
Philippi, Matthew ;
Arena, Christopher ;
Leake, Richard ;
Saltzman, Charles L. ;
Barg, Alexej .
FOOT & ANKLE INTERNATIONAL, 2022, 43 (01) :105-112
[5]   Correlation between indirect radiographic parameters of first metatarsal rotation in hallux valgus and values on weight-bearing computed tomography [J].
Barbachan Mansur, Nacime Salomao ;
Lalevee, Matthieu ;
Schmidt, Eli ;
Dibbern, Kevin ;
Wagner, Pablo ;
Wagner, Emilio ;
de Souza Nery, Caio Augusto ;
Netto, Cesar de Cesar .
INTERNATIONAL ORTHOPAEDICS, 2021, 45 (12) :3111-3118
[6]   Weightbearing Computed Tomography of the Foot and Ankle: Emerging Technology Topical Review [J].
Barg, Alexej ;
Bailey, Travis ;
Richter, Martinus ;
Netto, Cesar de Cesar ;
Lintz, Francois ;
Burssens, Arne ;
Phisitkul, Phinit ;
Hanrahan, Christopher J. ;
Saltzman, Charles L. .
FOOT & ANKLE INTERNATIONAL, 2018, 39 (03) :376-386
[7]   Intraobserver and interobserver reliability of cone beam weightbearing semi-automatic three-dimensional measurements in symptomatic pes cavovarus [J].
Bernasconi, Alessio ;
Cooper, Lucy ;
Lyle, Shirley ;
Patel, Shelain ;
Cullen, Nicholas ;
Singh, Dishan ;
Welck, Matthew .
FOOT AND ANKLE SURGERY, 2020, 26 (05) :564-572
[8]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[9]  
Braza S., 2021, J Foot Ankle, V15, P259
[10]   Reliability and correlation analysis of computed methods to convert conventional 2D radiological hindfoot measurements to a 3D setting using weightbearing CT [J].
Burssens, A. ;
Peeters, J. ;
Peiffer, M. ;
Marien, R. ;
Lenaerts, T. ;
Vandeputte, G. ;
Victor, J. .
INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2018, 13 (12) :1999-2008