Effect of preoperative deformity on postoperative leg axis in total knee arthroplasty: a prospective randomized study

被引:16
作者
Hsu, Wei-Hsiu [1 ]
Hsu, Robert Wen Wei [1 ]
Weng, Yi-Jan [1 ]
机构
[1] Chang Gung Mem Hosp, Div Sports Med, Dept Orthoped Surg, Chiayi, Taiwan
关键词
Preoperative deformity; Total knee arthroplasty; Computer-assisted surgery; COMPUTER-ASSISTED NAVIGATION; LOWER-EXTREMITY; ALIGNMENT; ACCURACY; ROTATION; FLEXION;
D O I
10.1007/s00167-010-1146-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Computer-assisted surgery-total knee arthroplasty (CAS-TKA) has been suggested to afford greater precision than conventional TKA; however, it is unclear whether this is influenced by preoperative angular deformity. This prospective study was conducted to determine the effect of preoperative angular deformity on the postoperative mechanical axis. Sixty patients underwent stage bilateral TKA; CAS-TKA was performed on one side and conventional TKA on the other side. It was demonstrated that severity of preoperative angular deformity affected the resulting alignment in conventional TKA, but not in CAS-TKA. The mechanical axis of the leg was within 3 degrees of the planned axis in 83% of CAS-TKA but only 32% of conventional TKA cases when the preoperative angular deformity was > 12 degrees (P < 0.01). When the preoperative angular deformity was < 12 degrees, the mechanical axis of the leg was within 3 degrees of the planned axis in 90% of CAS-TKA but only 69% of conventional TKA (P < 0.025). This study thus concluded that the resulting alignment in conventional TKA is influenced by large preoperative angular deformity. Consistent results in alignment can be achieved with CAS-TKA, though preoperative angular deformity still played a role in predicting the postoperative mechanical axis. CAS-TKA achieves better postoperative alignment than conventional TKA in both severe and mild preoperative angular deformity.
引用
收藏
页码:1323 / 1327
页数:5
相关论文
共 20 条
  • [1] Leg axis after computer-navigated total knee arthroplasty - A prospective randomized trial comparing computer-navigated and manual implantation
    Decking, R
    Markmann, Y
    Fuchs, J
    Puhl, W
    Scharf, HP
    [J]. JOURNAL OF ARTHROPLASTY, 2005, 20 (03) : 282 - 288
  • [2] EWALD FC, 1989, CLIN ORTHOP RELAT R, P9
  • [3] Computer-assisted navigation increases precision of component placement in total knee arthroplasty
    Haaker, RG
    Stockheim, M
    Kamp, M
    Proff, G
    Breitenfelder, J
    Ottersbach, A
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (433) : 152 - 159
  • [4] HSU RWW, 1990, CLIN ORTHOP RELAT R, P215
  • [5] INSALL JN, 1985, CLIN ORTHOP RELAT R, P13
  • [6] Effects of rotation on measurement of lower limb alignment for knee osteotomy
    Kawakami, H
    Sugano, N
    Yonenobu, K
    Yoshikawa, H
    Ochi, T
    Hattori, A
    Suzuki, N
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2004, 22 (06) : 1248 - 1253
  • [7] Underestimation of varus angulation in knees with flexion deformity
    Koshino, T
    Takeyama, M
    Jiang, LS
    Yoshida, T
    Saito, T
    [J]. KNEE, 2002, 9 (04) : 275 - 279
  • [8] A MATHEMATICAL-ANALYSIS OF THE EFFECT OF FLEXION AND ROTATION ON APPARENT VARUS VALGUS ALIGNMENT AT THE KNEE
    KRACKOW, KA
    PEPE, CL
    GALLOWAY, EJ
    [J]. ORTHOPEDICS, 1990, 13 (08) : 861 - 868
  • [9] A prospective, randomized study of computer-assisted and conventional total knee arthroplasty - Three-dimensional evaluation of implant alignment and rotation
    Matziolis, Georg
    Krocker, Doerte
    Weiss, Ulrike
    Tohtz, Stephan
    Perka, Carsten
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (02) : 236 - 243
  • [10] Reliability of measuring long-standing lower extremity radiographs
    Rauh, Michael A.
    Boyle, James
    Mihalko, William M.
    Phillips, Matthew J.
    Bayers-Thering, Mary
    Krackow, Kenneth A.
    [J]. ORTHOPEDICS, 2007, 30 (04) : 299 - 303