Determination of chlorine ions in raw milk by pulsed amperometric detection in a flow injection system

被引:13
作者
Chen, Xingguang [1 ]
Chu, Beibei [1 ]
Xi, Huiting [1 ]
Xu, Junjun [1 ]
Lai, Lizhi [1 ]
Peng, Huifeng [1 ]
Deng, Danwen [1 ]
Huang, Ganhui [1 ]
机构
[1] Nanchang Univ, State Key Lab Food Sci & Technol, Nanchang 330047, Jiangxi, Peoples R China
基金
中国国家自然科学基金;
关键词
chloride ion; pulsed amperometric detection; flow injection system; milk adulteration; ADULTERATION; CHROMATOGRAPHY; GOLD;
D O I
10.3168/jds.2018-14395
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
Chloride ion concentration in milk was determined by pulsed amperometric detection in a flow injection system. Results showed that the Au electrode lost 3 electrons at 1.10 V and formed chloroaurate ions (AuCl4-) by combining with chloride ions, after which AuCl4- was partly reduced to Au at 0.6 V. Based on the electrochemical process, a triple waveform with detection potential of 1.15 V, detection time of 150 ms, oxidation potential of 1.4 V, oxidation time of 550 ms, reduction potential of 0 V, and reduction time of 400 ms was applied to the Au electrode for detecting chloride ion concentration in milk. The approach is rapid and automatic and features a detection limit of 0.005 g/L. The relative standard deviation obtained by 60 repetitive injections reached 1.48% at 2 g/L of NaCl. The method developed using the Au electrode without modification was used to analyze the chloride ion concentration in raw milk without preprocessing. The method showed good agreement with potentiometric titration.
引用
收藏
页码:9647 / 9658
页数:12
相关论文
共 50 条
  • [1] Flow injection and HPLC determination of furosemide using pulsed amperometric detection at microelectrodes
    Guzmán, A
    Agüí, L
    Pedrero, M
    Yáñez-Sedeño, P
    Pingarrón, JM
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 33 (05) : 923 - 933
  • [2] Quadruple-pulsed amperometric detection for simultaneous flow injection determination of glucose and fructose
    Surareungchai, W
    Deepunya, W
    Tasakorn, P
    ANALYTICA CHIMICA ACTA, 2001, 448 (1-2) : 215 - 220
  • [3] Determination of 2-furaldehyde in transformer oil using flow injection with pulsed amperometric detection
    Dilleen, JW
    Lawrence, CM
    Slater, JM
    ANALYST, 1996, 121 (06) : 755 - 759
  • [4] Flow injection analysis of tetracycline in pharmaceutical formulation with pulsed amperometric detection
    Palaharn, S
    Charoenraks, T
    Wangfuengkanagul, N
    Grudpan, K
    Chailapakul, O
    ANALYTICA CHIMICA ACTA, 2003, 499 (1-2) : 191 - 197
  • [5] Flow injection analysis of doxycycline or chlortetracycline in pharmaceutical formulations with pulsed amperometric detection
    Charoenraks, T
    Palaharn, S
    Grudpan, K
    Siangproh, W
    Chailapakul, O
    TALANTA, 2004, 64 (05) : 1247 - 1252
  • [6] Flow injection determination of chloride ions with spectrophotometric detection
    Cheregi, M
    Danet, AF
    ANALYTICAL LETTERS, 1997, 30 (15) : 2847 - 2858
  • [7] DETERMINATION OF THE ANTIOXIDANT IRGANOX-1076 BY ANODIC VOLTAMMETRY AND FLOW-INJECTION WITH PULSED AMPEROMETRIC DETECTION AT A GLASSY-CARBON ELECTRODE
    AGUI, ML
    CALAVIA, E
    YANEZSEDENO, P
    PINGARRON, JM
    ANALYTICA CHIMICA ACTA, 1995, 305 (1-3) : 324 - 331
  • [8] Sub-millimolar determination of formalin by pulsed amperometric detection
    Ngamchana, S
    Surareungchai, W
    ANALYTICA CHIMICA ACTA, 2004, 510 (02) : 195 - 201
  • [9] Determination of kanamycin sulfate by liquid chromatography with pulsed amperometric detection
    Xi Ling-Ling
    Zhu Yan
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2007, 35 (05) : 703 - 706
  • [10] Determination of biogenic amines by capillary electrophoresis with pulsed amperometric detection
    Sun, XH
    Yang, XR
    Wang, EK
    JOURNAL OF CHROMATOGRAPHY A, 2003, 1005 (1-2) : 189 - 195