Spine stability after implantation of an interspinous device: an in vitro and finite element biomechanical study

被引:14
作者
Anesetti, Federica [1 ]
Galbusera, Fabio [1 ,2 ]
Aziz, Hadi N. [1 ,3 ]
Bellini, Chiara M. [1 ]
Addis, Alessandro [4 ]
Villa, Tomaso [5 ]
Teli, Marco [1 ]
Lovi, Alessio [1 ]
Brayda-Bruno, Marco [1 ]
机构
[1] IRCCS Ist Ortoped Galeazzi, I-20161 Milan, Italy
[2] Univ Ulm, Inst Orthoped Res & Biomech, D-89069 Ulm, Germany
[3] Stryker Italia Srl, Formello, Italy
[4] Univ Milan, Fac Vet Med, I-20122 Milan, Italy
[5] Politecn Milan, LaBS, I-20133 Milan, Italy
关键词
dynamic stabilization; lumbar stenosis; spine biomechanics; interspinous implant; LUMBAR SPINE; DEGENERATIVE SPONDYLOLISTHESIS; COST-EFFECTIVENESS; STENOSIS; FUSION; MODEL; DISC; CALIBRATION; SEGMENT;
D O I
10.3171/2010.6.SPINE09885
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. Interspinous devices are widely used for the treatment of lumbar stenosis. The DIAM spinal stabilization system (Medtronic, Ltd.) is an interspinous implant made of silicone and secured in place with 2 laces. The device can be implanted via posterior access with the sacrifice of the supraspinous ligament (SSL) or via lateral access with preservation of the ligament. The aim of the present work was to evaluate the role of the laces, the SSL, and the device size and positioning to determine the device's ability in reducing segmental lordosis and in stabilizing motion. Methods. Biomechanical tests were performed in flexion and extension on 8 porcine spines implanted with the DIAM either with or without the laces and the SSL. A finite element model of the human L4-5 spine segments was also created and used to test 2 sizes of the device implanted in 2 different positions in the anteroposterior direction. Results. Implantation of the DIAM induced a shift toward kyphosis in the neutral position. Laces, the SSL, and device size and placement had a significant influence on the neutral position, the stiffness of the implanted spine, and the positions of the instantaneous centers of rotation. Conclusions. The shift of the neutral position toward kyphosis may be beneficial in reducing symptoms of spinal stenosis such as radicular pain, sensation disturbance, and loss of strength in the legs. The authors recommend preservation of the SSL and the use of the fixation laces, given their relevant mechanical role. Choosing the proper device size and placement should be achieved by using a correct surgical technique. (DOI: 10.3171/2010.6.SPINE09885)
引用
收藏
页码:568 / 575
页数:8
相关论文
共 23 条
[1]  
An Y., 1999, ANIMAL MODELS ORTHOP, P505
[2]  
Aziz HN, 2008, COMPARATIVE MED, V58, P174
[3]   Biomechanics of the lumbar spine after dynamic stabilization [J].
Bellini, Chiara Maria ;
Galbusera, Fabio ;
Raimondi, Manuela T. ;
Mineo, Gittseppe V. ;
Brayda-Bruno, Marco .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2007, 20 (06) :423-429
[4]   Intervertebral disc herniation: studies on a porcine model exposed to highly repetitive flexion/extension motion with compressive force [J].
Callaghan, JP ;
McGill, SM .
CLINICAL BIOMECHANICS, 2001, 16 (01) :28-37
[5]   Biomechanical responses of the intervertebral joints to static and vibrational loading: a finite element study [J].
Cheung, JTM ;
Zhang, M ;
Chow, DHK .
CLINICAL BIOMECHANICS, 2003, 18 (09) :790-799
[6]   Degenerative lumbar spinal stenosis: analysis of results in a series of 374 patients treated with unilateral laminotomy for bilateral microdecompression [J].
Costa, Francesco ;
Sassi, Marco ;
Cardia, Andrea ;
Ortolina, Alessandro ;
De Santis, Antonio ;
Luccarell, Giovanni ;
Fornari, Maurizio .
JOURNAL OF NEUROSURGERY-SPINE, 2007, 7 (06) :579-586
[7]   Biomechanical analysis of cages for posterior lumbar interbody fusion [J].
Fantigrossi, Alfonso ;
Galbusera, Fabio ;
Raimondi, Manuela Teresa ;
Sassi, Marco ;
Fornari, Maurizio .
MEDICAL ENGINEERING & PHYSICS, 2007, 29 (01) :101-109
[8]  
Keaveny T.M., 2001, BONE MECH HDB
[9]   Are the spines of calf, pig and sheep suitable models for pre-clinical implant tests? [J].
Kettler, A. ;
Liakos, L. ;
Haegele, B. ;
Wilke, H. -J. .
EUROPEAN SPINE JOURNAL, 2007, 16 (12) :2186-2192
[10]   Does Wallis implant reduce adjacent segment degeneration above lumbosacral instrumented fusion? [J].
Korovessis, Panagiotis ;
Repantis, Thomas ;
Zacharatos, Spyros ;
Zafiropoulos, Andreas .
EUROPEAN SPINE JOURNAL, 2009, 18 (06) :830-840