Two-dimensional model for tapered pulse tubes. Part 2: mass streaming and streaming-driven enthalpy flow loss

被引:13
作者
Baek, SH
Jeong, ES
Jeong, S
机构
[1] Hongik Univ, Dept Mech Engn, Seoul 121791, South Korea
[2] Korea Adv Inst Sci & Technol, Dept Mech Engn, Taejon 305701, South Korea
关键词
pulse tube refrigerators; tapered pulse tubes; two-dimensional model; mass streaming; streaming-driven enthalpy flow loss;
D O I
10.1016/S0011-2275(00)00058-8
中图分类号
O414.1 [热力学];
学科分类号
摘要
The effects of the taper angle and the frequency on the steady mass flux and the enthalpy flow loss associated with the steady mass streaming were analyzed by two-dimensional analysis of the tapered pulse tube. It was shown that the mass streaming could lead to a large steady second-order temperature, The enthalpy flow loss driven by the mass streaming increases as the frequency increases. For the pulse tube where the viscous penetration depth is far thinner than the inner radius, the enthalpy flow loss can be significantly reduced by tapering the pulse tube since the steady mass flux and the steady second-order temperature decrease as the taper angle increases. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:387 / 392
页数:6
相关论文
共 7 条
[1]   Two-dimensional model for tapered pulse tubes. Part 1: theoretical modeling and net enthalpy flow [J].
Baek, SH ;
Jeong, FS ;
Jeong, S .
CRYOGENICS, 2000, 40 (06) :379-385
[2]   Secondary flow in basic pulse tube refrigerators [J].
Jeong, ES .
CRYOGENICS, 1996, 36 (05) :317-323
[3]  
LEE JM, 1997, CRYOCOOLERS, V9, P345
[4]  
LEE JM, 1995, CRYOCOOLERS, V8, P359
[5]  
LEE JM, 1993, P 7 INT CRYOC C, P125
[6]   Acoustic streaming in pulse tube refrigerators: tapered pulse tubes [J].
Olson, JR ;
Swift, GW .
CRYOGENICS, 1997, 37 (12) :769-776
[7]  
ROTT N, 1974, J APPL MATH PHYS, V25, P417