Comparison of Readout-Segmented Echo-Planar Imaging and Single-Shot TSE DWI for Cholesteatoma Diagnostics

被引:12
作者
Wiesmueller, M. [1 ,2 ]
Wuest, W. [1 ,2 ]
May, M. S. [1 ,2 ]
Ellmann, S. [1 ]
Heiss, R. [1 ,2 ]
Saake, M. [1 ,2 ]
Janka, R. [1 ,2 ]
Uder, M. [1 ,2 ]
Laun, F. B. [1 ]
机构
[1] Friedrich Alexander Univ Erlangen Nurnberg, Univ Hosp Erlangen, Inst Radiol, Erlangen, Germany
[2] Friedrich Alexander Univ Erlangen Nurnberg, Univ Hosp Erlangen, Image Sci Inst, Erlangen, Germany
关键词
MIDDLE-EAR CHOLESTEATOMA; RECURRENT CHOLESTEATOMA; RESIDUAL CHOLESTEATOMA; SPINAL-CORD; DIFFUSION; MRI; DISTORTIONS; ACCURACY; SEQUENCE; CT;
D O I
10.3174/ajnr.A7112
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: The high diagnostic value of DWI for cholesteatoma diagnostics is undisputed. This study compares the diagnostic value of readout-segmented echo-planar DWI and single-shot TSE DWI for cholesteatoma diagnostics. MATERIALS AND METHODS: Thirty patients with newly suspected cholesteatoma were examined with a dedicated protocol, including readout-segmented echo-planar DWI and single-shot TSE DWI at 1.5T. Acquisition parameters of both diffusion-weighted sequences were as follows: b=1000 s/mm,(2) axial and coronal section orientations, and section thickness of 3 mm. Image quality was evaluated by 2 readers on a 5-point Likert scale with respect to lesion conspicuity, the presence of susceptibility artifacts mimicking cholesteatomas, and overall subjective image quality. Sensitivity and specificity were calculated using histology results as the gold standard. RESULTS: Twenty-five cases of histologically confirmed cholesteatomas were included in the study group. Lesion conspicuity was higher and fewer artifacts were found when using TSE DWI (both P<.001). The overall subjective image quality, however, was better with readout-segmented DWI. For TSE DWI, the sensitivity for readers 1 and 2 was 92% (95% CI, 74%-99%) and 88% (95% CI, 69%-97%), respectively, while the specificity for both readers was 80% (95% CI, 28%-99%). For readout-segmented DWI, the sensitivity for readers 1 and 2 was 76% (95% CI, 55%-91%) and 68% (95% CI, 46%-85%), while the specificity for both readers was 60% (95% CI, 15%-95%). CONCLUSIONS: The use of TSE DWI is advisable for cholesteatoma diagnostics and preferable over readout-segmented DWI.
引用
收藏
页码:1305 / 1312
页数:8
相关论文
共 38 条
[1]   Diffusion-weighted MR imaging of cholesteatoma in pediatric and adult patients who have undergone middle ear surgery [J].
Aikele, P ;
Kittner, T ;
Offergeld, C ;
Kaftan, H ;
Hüttenbrink, KB ;
Laniado, M .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (01) :261-265
[2]   Detection of cholesteatoma: High-resolution DWI using RS-EPI and parallel imaging at 3 tesla [J].
Algin, O. ;
Aydin, H. ;
Ozmen, E. ;
Ocakoglu, G. ;
Bercin, S. ;
Porter, D. A. ;
Kutluhan, A. .
JOURNAL OF NEURORADIOLOGY, 2017, 44 (06) :388-394
[3]   Phase insensitive preparation of single-shot RARE: Application to diffusion imaging in humans [J].
Alsop, DC .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (04) :527-533
[4]   How to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imaging [J].
Andersson, JLR ;
Skare, S ;
Ashburner, J .
NEUROIMAGE, 2003, 20 (02) :870-888
[5]   Diffusion-weighted magnetic resonance imaging in the detection of residual and recurrent cholesteatoma in children: A systematic review and meta-analysis [J].
Bazzi, Khalil ;
Wong, Eugene ;
Jufas, Nicholas ;
Patel, Nirmal .
INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2019, 118 :90-96
[6]   Cholesteatoma Localization Using Fused Diffusion-Weighted Images and Thin-Slice T2 Weighted Images [J].
Benson, John C. ;
Carlson, Matthew L. ;
Yin, Linda ;
Lane, John I. .
LARYNGOSCOPE, 2021, 131 (05) :E1662-E1667
[7]   The value of single-shot turbo spin-echo diffusion-weighted MR imaging in the detection of middle ear cholesteatoma [J].
De Foer, Bert ;
Vercruysse, Jean-Philippe ;
Bernaerts, Anja ;
Maes, Joachim ;
Deckers, Filip ;
Michiels, Johan ;
Somers, Thomas ;
Pouillon, Marc ;
Offeciers, Erwin ;
Casselman, Jan W. .
NEURORADIOLOGY, 2007, 49 (10) :841-848
[8]   Contiguous-Slice Zonally Oblique Multislice (CO-ZOOM) Diffusion Tensor Imaging: Examples of In Vivo Spinal Cord and Optic Nerve Applications [J].
Dowell, Nicholas G. ;
Jenkins, Thomas M. ;
Ciccarelli, Olga ;
Miller, David H. ;
Wheeler-Kingshott, Claudia A. M. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 29 (02) :454-460
[9]   The Diagnostic Accuracy of Non-Echo-Planar Diffusion-Weighted Imaging in the Detection of Residual and/or Recurrent Cholesteatoma of the Temporal Bone [J].
Dremmen, M. H. G. ;
Hofman, P. A. M. ;
Hof, J. R. ;
Stokroos, R. J. ;
Postma, A. A. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (03) :439-444
[10]   Diffusion-weighted MR imaging sequence in the detection of postoperative recurrent cholesteatoma [J].
Dubrulle, F ;
Souillard, R ;
Chechin, D ;
Vaneecloo, FM ;
Desaulty, A ;
Vincent, C .
RADIOLOGY, 2006, 238 (02) :604-610