Estimation and validation of patient-specific high-resolution lung elasticity derived from 4DCT

被引:11
|
作者
Hasse, Katelyn [1 ]
O'Connell, Dylan [1 ]
Min, Yugang [1 ]
Neylon, John [1 ]
Low, Daniel A. [1 ]
Santhanam, Anand [1 ]
机构
[1] Univ Calif Los Angeles, Dept Radiat Oncol, Los Angeles, CA 90024 USA
基金
美国国家科学基金会;
关键词
4DCT; biomechanical modeling; lung elastography; lung radiotherapy; MAGNETIC-RESONANCE ELASTOGRAPHY; DEFORMABLE IMAGE REGISTRATION; COMPUTED-TOMOGRAPHY; GUIDED RADIOTHERAPY; MODEL; RECONSTRUCTION; ACQUISITION; PARENCHYMA; CANCER; DELINEATION;
D O I
10.1002/mp.12697
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Lung diseases are commonly associated with changes in lung tissue's biomechanical properties. Functional imaging techniques, such as elastography, have shown great promise in measuring tissue's biomechanical properties, which could expand the utility and effectiveness of radiotherapy treatment planning. We present a novel methodology for characterizing a key biomechanical property, parenchymal elasticity, derived solely from 4DCT datasets. Methods: Specifically, end-inhalation and end-exhalation breathing phases of the 4DCT datasets were deformably registered and the resulting displacement maps were considered to be ground-truth. A mid-exhalation image was also prepared for verification purposes. A GPU-based biomechanical model was then generated from the patient end-exhalation dataset and used as a forward model to iteratively solve for the elasticity distribution. Displacements at the surface of the lungs were applied as boundary constraints for the model-guided tissue elastography, while the inner voxels were allowed to deform according to the linear elastic forces within the biomechanical model. A convergence criteria of 10% maximum deformation was employed for the iterative process. Results: The lung tissue elasticity estimation was documented for a set of 15 4DCT patient datasets. Maximum lung deformations were observed to be between 6 and 31 mm. Our results showed that, on average, 89.91 +/- 4.85% convergence was observed. A validation study consisting of mid-exhalation breathing phases illustrated an accuracy of 87.13 +/- 10.62%. Structural similarity, normalized cross-correlation, and mutual information were used to quantify the degree of similarity between the following image pairs: (a) the model-generated end-exhalation and ground-truth end-exhalation, and (b) model-generated mid-exhalation images and ground-truth mid-exhalation. Conclusions: Overall, the results suggest that the lung elasticity can be measured with approximately 90% convergence using routinely acquired clinical 4DCT scans, indicating the potential for a lung elastography implementation within the radiotherapy clinical workflow. The regional lung elasticity found here can lead to improved tissue sparing radiotherapy treatment plans, and more precise monitoring of treatment response. (C) 2017 American Association of Physicists in Medicine
引用
收藏
页码:666 / 677
页数:12
相关论文
共 13 条
  • [1] Patient-specific motion artifacts in 4DCT
    Watkins, W. Tyler
    Li, Ruijiang
    Lewis, John
    Park, Justin C.
    Sandhu, Ajay
    Jiang, Steve B.
    Song, William Y.
    MEDICAL PHYSICS, 2010, 37 (06) : 2855 - 2861
  • [2] Proton radiography and fluoroscopy of lung tumors: A Monte Carlo study using patient-specific 4DCT phantoms
    Han, Bin
    Xu, X. George
    Chen, George T. Y.
    MEDICAL PHYSICS, 2011, 38 (04) : 1903 - 1911
  • [3] Patient-Specific Simulation of Cardiac Blood Flow From High-Resolution Computed Tomography
    Lantz, Jonas
    Henriksson, Lilian
    Persson, Anders
    Karlsson, Matts
    Ebbers, Tino
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2016, 138 (12):
  • [4] Virtual 4DCT generated from 4DMRI in gated particle therapy: phantom validation and application to lung cancer patients
    Annunziata, S.
    Rabe, M.
    Vai, A.
    Molinelli, S.
    Nakas, A.
    Meschini, G.
    Pella, A.
    Vitolo, V.
    Barcellini, A.
    Imparato, S.
    Ciocca, M.
    Orlandi, E.
    Landry, G.
    Kamp, F.
    Kurz, C.
    Baroni, G.
    Riboldi, M.
    Paganelli, C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (14)
  • [5] Dynamic lung compliance imaging from 4DCT-derived volume change estimation
    Nair, Girish B.
    Al-Katib, Sayf
    Podolsky, Robert
    Quinn, Thomas
    Stevens, Craig
    Castillo, Edward
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (21)
  • [6] Patient-Specific Biomechanical Model for the Prediction of Lung Motion From 4-D CT Images
    Fuerst, Bernhard
    Mansi, Tommaso
    Carnis, Francois
    Saelzle, Martin
    Zhang, Jingdan
    Declerck, Jerome
    Boettger, Thomas
    Bayouth, John
    Navab, Nassir
    Kamen, Ali
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (02) : 599 - 607
  • [7] Selection of patient for gated treatment based on the information from 4DCT imaging in stereotactic body radiotherapy of non-small cell lung cancer
    Sresty, N. V. N. Madhusudhana
    Raju, A. Krishnam
    Sharma, S. D.
    Kumar, T. Anil
    Ahamed, Shabbir
    Bajwa, Harjot Kaur
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2019, 18 (02) : 175 - 179
  • [8] Fluoroscopic 3D Image Generation from Patient-Specific PCA Motion Models Derived from 4D-CBCT Patient Datasets: A Feasibility Study
    Dhou, Salam
    Alkhodari, Mohanad
    Ionascu, Dan
    Williams, Christopher
    Lewis, John H.
    JOURNAL OF IMAGING, 2022, 8 (02)
  • [9] First validation of high-resolution satellite-derived methane emissions from an active gas leak in the UK
    Dowd, Emily
    Manning, Alistair J.
    Orth-Lashley, Bryn
    Girard, Marianne
    France, James
    Fisher, Rebecca E.
    Lowry, Dave
    Lanoiselle, Mathias
    Pitt, Joseph R.
    Stanley, Kieran M.
    O'Doherty, Simon
    Young, Dickon
    Thistlethwaite, Glen
    Chipperfield, Martyn P.
    Gloor, Emanuel
    Wilson, Chris
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2024, 17 (05) : 1599 - 1615
  • [10] Comparison between target margins derived from 4DCT scans and real-time tumor motion tracking: Insights from lung tumor patients treated with robotic radiosurgery
    Descovich, Martina
    McGuinness, Christopher
    Kannarunimit, Danita
    Chen, Josephine
    MEDICAL PHYSICS, 2015, 42 (03) : 1280 - 1287