High frequency investigation of single-switch CCM power factor correction converter

被引:0
作者
Lu, B [1 ]
Dong, W [1 ]
Wang, S [1 ]
Lee, FC [1 ]
机构
[1] Virginia Polytech Inst & State Univ, Ctr Power Elect Syst, Bradley Dept Elect & Comp Engn, Blacksburg, VA 24061 USA
来源
APEC 2004: NINETEENTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, VOLS 1-3 | 2004年
关键词
high frequency; power factor correction;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
To. achieve higher power density, power converters are operating at higher switching frequencies. For the high switching frequency operating, not only the efficiency, but also the EMI performance is a big concern. In this paper, based on the developed EMI noise model, switching frequency impact on the single-switch CCM PFC is analyzed and evaluated. Switching frequency selection guideline is given.
引用
收藏
页码:1481 / 1487
页数:7
相关论文
共 7 条
[1]  
BING L, 2003, P IEEE APEC
[2]  
*CISPR, BSEN550221998 CISPR
[3]  
JOVANOVIC MM, 1992, 6 INT C POW SEM THEI
[4]  
NAVE MJ, 1989, IEEE APEC, P3
[5]   A procedure for designing EMI filters for AC line applications [J].
Shih, FY ;
Chen, DY ;
Wu, YP ;
Chen, YT .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 1996, 11 (01) :170-181
[6]  
TING G, 1996, POWER ELECT IEEE T, V11, P480
[7]  
ADOPTED SPECIFICATIO