Monitoring cellular stress responses to nanoparticles using a lab-on-a-chip

被引:36
作者
Richter, Lukas [1 ]
Charwat, Verena [1 ]
Jungreuthmayer, Christian [2 ]
Bellutti, Florian [1 ]
Brueckl, Hubert [1 ]
Ertl, Peter [1 ]
机构
[1] AIT, Dept Hlth & Environm, A-1220 Vienna, Austria
[2] AIT, Dept Mobil, A-1210 Vienna, Austria
关键词
DIELECTRIC-SPECTROSCOPY; MICROFLUIDIC BIOCHIP; FIBROBLASTS; CULTURE; SYSTEMS; NANOTOXICOLOGY; TECHNOLOGY; PARTICLES; MOLECULES; DYNAMICS;
D O I
10.1039/c1lc20256a
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
As nanotechnology moves towards widespread commercialization, new technologies are needed to adequately address the potential health impact of nanoparticles (NPs). Assessing the safety of over 30 000 NPs through animal testing would not only be expensive, but it would also raise a number of ethical considerations. Furthermore, existing in vitro cell-based assays are not sufficient in scope to adequately address the complexity of cell-nanoparticle interactions including NP translocation, accumulation and co-transport of e.g. allergens. In particular, classical optical/fluorescent endpoint detection methods are known to provide irreproducible, inaccurate and unreliable results since these labels can directly react with the highly catalytic surfaces of NP. To bridge this technological gap we have developed a lab-on-a-chip capable of continuously and non-invasively monitoring the collagen production of primary human fibroblast cells (NHDF) using contactless dielectric microsensors. Human dermal fibroblast cells are responsible for the maintenance of soft tissue integrity, are found throughout the human body and their primary function is collagen expression. We show that cellular collagen production can be readily detected and used to assess cellular stress responses to a variety of external stimuli, including exposure to nanoparticles. Results of the study showed a 20% and 95% reduction of collagen production following 4 hour exposure to 10 mu g mL(-1) gold and silver nanoparticles (dia. 10 nm), respectively. Furthermore a prolonged perfusion of sub-toxic concentrations (0.1 mu g mL(-1)) of silver NP reduced NHDF collagen production by 40% after 10 h indicating increased NP take up and accumulation. We demonstrate that the application of microfluidics for the tailored administration of different NP treatments constitutes a powerful new tool to study cell-nanoparticle interactions and nanoparticle accumulation effects in small cell populations.
引用
收藏
页码:2551 / 2560
页数:10
相关论文
共 47 条
  • [1] Microfluidic devices for cellomics: a review
    Andersson, H
    van den Berg, A
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2003, 92 (03): : 315 - 325
  • [2] [Anonymous], J APPL PHYS
  • [3] Asami K, 2000, YEAST, V16, P1359, DOI 10.1002/1097-0061(200011)16:15<1359::AID-YEA631>3.0.CO
  • [4] 2-E
  • [5] Detection of viruses with molecularly imprinted polymers integrated on a microfluidic biochip using contact-less dielectric microsensors
    Birnbaumer, Gerald M.
    Lieberzeit, Peter A.
    Richter, Lukas
    Schirhagl, Romana
    Milnera, Marcus
    Dickert, Franz L.
    Bailey, Andrew
    Ertl, Peter
    [J]. LAB ON A CHIP, 2009, 9 (24) : 3549 - 3556
  • [6] On-chip hydrodynamic chromatography separation and detection of nanoparticles and biomolecules
    Blom, MT
    Chmela, E
    Oosterbroek, RE
    Tijssen, R
    van den Berg, A
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (24) : 6761 - 6768
  • [7] Microfluidics-based systems biology
    Breslauer, DN
    Lee, PJ
    Lee, LP
    [J]. MOLECULAR BIOSYSTEMS, 2006, 2 (02) : 97 - 112
  • [8] Cellular dielectric spectroscopy: A powerful new approach to label-free cellular analysis
    Ciambrone, GJ
    Liu, VF
    Lin, DC
    McGuinness, RP
    Leung, GK
    Pitchford, S
    [J]. JOURNAL OF BIOMOLECULAR SCREENING, 2004, 9 (06) : 467 - 480
  • [9] Cliff W.J., 1976, BLOOD VESSELS
  • [10] CLIFT MJD, 2010, ARCH TOXICOL, P1