摘要
The determination of very low concentrations of plutonium, in the femtogram per millilitre range, in environmental samples using ICP-MS can be interfered by polyatomic species containing heavy elements, from hafnium to bismuth. Mass-to-charge ratios of these polyatomic species are very close to the ones of the plutonium isotopes and cannot be separated from them in the low resolution mode currently used for trace analysis. In this paper, we present an evaluation of the extent and impact of these interferences on the background at masses of plutonium isotopes Pu-239 and Pu-240, based on measurement of environmental samples for three years using a double-focusing sector-field ICP-MS. We demonstrate that these molecular interferences, especially the ones involving lead, mercury, and iridium through species PbO2+, ArHg+, IrO3+, must be considered as the additional background induced by these interferences (on average for all interferences respectively similar to 1.2 and similar to 1.9 counts s(-1) at 239 and 240 atomic mass units) is often higher than the instrumental background measured with deionised water acidified at 2% by ultra- pure grade HNO3 (similar to 0.4 counts s(-1)), and are generally of the same order as other usual sources of background for low-level plutonium analysis by ICP-MS, i.e. Pu-242 tracer isotopic impurities, U-238 hydrides and peak tail. Thus, if not corrected, these polyatomic interferences may lead to false detection of femtogram amounts of plutonium or overestimation of results. The extents of formation of the main polyatomic species are highly variable from one analysis to the other, over one or two orders of magnitude, depending on instrumental settings. Chemical purification procedures are very efficient in eliminating the greater part of heavy elements present in the initial samples. However, these procedures also bring heavy elements into the final sample solutions through contamination by the atmosphere, glassware and reagents.
引用
收藏
页码:1474 / 1480
页数:7
相关论文
共 32 条
  • [1] Evaluation of a single collector, double focusing sector field inductively coupled plasma mass spectrometer for the determination of U and Pu concentrations and isotopic compositions at trace level
    Baglan, N
    Hemet, P
    Pointurier, F
    Chiappini, R
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2004, 261 (03) : 609 - 617
  • [2] Environmental monitoring of plutonium at ultratrace level in natural water (Sea of Galilee-Israel) by ICP-SFMS and MC-ICP-MS
    Becker, JS
    Zoriy, M
    Halicz, L
    Teplyakov, N
    Müller, C
    Segal, I
    Pickhardt, C
    Platzner, IT
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (09) : 1257 - 1261
  • [3] Double-focusing sector field inductively coupled plasma mass spectrometry for highly sensitive multi-element and isotopic analysis - Invited lecture
    Becker, JS
    Dietze, HJ
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (09) : 881 - 889
  • [4] Analysis of IAEA environmental samples for plutonium and uranium by ICP/MS in support of international safeguards
    Farmer, O. T., III
    Olsen, K. B.
    Thomas, M. L.
    Garofoli, S. J.
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2008, 276 (02) : 489 - 492
  • [5] Determination of plutonium isotopes and neptunium-237 in environmental samples by inductively coupled plasma mass spectrometry with total sample dissolution
    Kenna, TC
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (11) : 1471 - 1479
  • [6] Resolving global versus local/regional Pu sources in the environment using sector ICP-MS
    Ketterer, ME
    Hafer, KM
    Link, CL
    Kolwaite, D
    Wilson, J
    Mietelski, JW
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (02) : 241 - 245
  • [7] Simultaneous analysis of 237Np and Pu isotopes in environmental samples by ICP-SF-MS coupled with automated sequential injection system
    Kim, CS
    Kim, CK
    Lee, KJ
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (06) : 743 - 750
  • [8] Rapid and automated sequential determination of ultra-trace long-lived actinides in air filters by inductively coupled plasma mass spectrometry
    Lariviere, Dominic
    Benkhedda, Karima
    Kiser, Stephen
    Johnson, Sonia
    Cornett, R. Jack
    [J]. ANALYTICAL METHODS, 2010, 2 (03) : 259 - 267
  • [9] Analysis of plutonium isotopes in marine samples by radiometric, ICP-MS and AMS techniques
    Lee, SH
    Gastaud, J
    La Rosa, JJ
    Kwong, LLW
    Povinec, PP
    Wyse, E
    Fifield, LK
    Hausladen, PA
    Di Tada, LM
    Santos, GM
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2001, 248 (03) : 757 - 764
  • [10] Determination of plutonium isotopes in freshwater lake sediments by sector-field ICP-MS after separation using ion-exchange chromatography
    Liao, Haiqing
    Zheng, Jian
    Wu, Fengchang
    Yamada, Masatoshi
    Tan, Mingguang
    Chen, Jianmin
    [J]. APPLIED RADIATION AND ISOTOPES, 2008, 66 (08) : 1138 - 1145