Evaluating the potential for quantitative monitoring of in situ chemical oxidation of aqueous-phase TCE using in-phase and quadrature electrical conductivity

被引:10
作者
Hort, R. D. [1 ]
Revil, A. [2 ,3 ]
Munakata-Marr, J. [1 ]
Mao, D. [2 ]
机构
[1] Colorado Sch Mines, Dept Civil & Environm Engn, Golden, CO 80401 USA
[2] Colorado Sch Mines, Dept Geophys, Golden, CO 80401 USA
[3] Univ Savoie, CNRS, ISTerre, UMR 5275,Equipe Volcan, Le Bourget Du Lac, France
关键词
trichloroethene; permanganate; in situ chemical oxidation; complex conductivity; induced polarization; SPECTRAL INDUCED POLARIZATION; COMPLEX CONDUCTIVITY; RESISTIVITY; KINETICS; SILICA; TIME; PERMANGANATE; INVERSION; SAND; TRICHLOROETHYLENE;
D O I
10.1002/2014WR016868
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Electrical resistivity measurements can potentially be used to remotely monitor fate and transport of ionic oxidants such as permanganate (MnO4-) during in situ chemical oxidation (ISCO) of contaminants like trichloroethene (TCE). Time-lapse two-dimensional bulk conductivity and induced polarization surveys conducted during a sand tank ISCO simulation demonstrated that MnO4- plume movement could be monitored in a qualitative manner using bulk conductivity tomograms, although chargeability was below sensitivity limits. We also examined changes to in-phase and quadrature electrical conductivity resulting from ion injection, MnO2 and Cl- production, and pH change during TCE and humate oxidation by MnO4- in homogeneous aqueous solutions and saturated porous media samples. Data from the homogeneous samples demonstrated that inversion of the sand tank resistivity data using a common Tikhonov regularization approach was insufficient to recover an accurate conductivity distribution within the tank. While changes to in-phase conductivity could be successfully modeled, quadrature conductivity values could not be directly related to TCE oxidation product or MnO4- concentrations at frequencies consistent with field induced polarization surveys, limiting the utility of quadrature conductivity for monitoring ISCO.
引用
收藏
页码:5239 / 5259
页数:21
相关论文
共 48 条
[1]   The electrical resistivity log as an aid in determining some reservoir characteristics [J].
Archie, GE .
TRANSACTIONS OF THE AMERICAN INSTITUTE OF MINING AND METALLURGICAL ENGINEERS, 1942, 146 :54-61
[2]  
Baird R.B., 2005, Standard methods for the examination of water and wastewater
[3]   Electrical resistivity and induced polarization tomography in identifying the plume of chlorinated hydrocarbons in sedimentary formation: a case study in Rho (Milan-Italy) [J].
Cardarelli, Ettore ;
Di Filippo, Gerardina .
WASTE MANAGEMENT & RESEARCH, 2009, 27 (06) :595-602
[4]   A saline trace test monitored via time-lapse surface electrical resistivity tomography [J].
Cassiani, Giorgio ;
Bruno, Vittorio ;
Villa, Alberto ;
Fusi, Nicoletta ;
Binley, Andrew M. .
JOURNAL OF APPLIED GEOPHYSICS, 2006, 59 (03) :244-259
[5]   Kinetics of the oxidation of methyl tert-butyl ether (MTBE) by potassium permanganate [J].
Damm, JH ;
Hardacre, C ;
Kalin, RM ;
Walsh, KP .
WATER RESEARCH, 2002, 36 (14) :3638-3646
[6]   Applying petrophysical models to radar travel time and electrical resistivity tomograms: Resolution-dependent limitations [J].
Day-Lewis, FD ;
Singha, K ;
Binley, AM .
JOURNAL OF GEOPHYSICAL RESEARCH-SOLID EARTH, 2005, 110 (B8) :1-17
[7]   From Repulsion to Attraction and Back to Repulsion: The Effect of NaCl, KCl, and CsCl on the Force between Silica Surfaces in Aqueous Solution [J].
Dishon, Matan ;
Zohar, Ohad ;
Sivan, Uri .
LANGMUIR, 2009, 25 (05) :2831-2836
[8]   Evidence of the existence of three types of species at the quartz-aqueous solution interface at pH 0-10: XPS surface group quantification and surface complexation modeling [J].
Duval, Y ;
Mielczarski, JA ;
Pokrovsky, OS ;
Mielczarski, E ;
Ehrhardt, JJ .
JOURNAL OF PHYSICAL CHEMISTRY B, 2002, 106 (11) :2937-2945
[9]   Soil properties influencing apparent electrical conductivity: a review [J].
Friedman, SP .
COMPUTERS AND ELECTRONICS IN AGRICULTURE, 2005, 46 (1-3) :45-70
[10]   Electrical Resistivity Imaging of a Permanganate Injection During In Situ Treatment of RDX-Contaminated Groundwater [J].
Halihan, Todd ;
Albano, Jeffrey ;
Comfort, Steve D. ;
Zlotnik, Vitaly A. .
GROUND WATER MONITORING AND REMEDIATION, 2012, 32 (01) :43-52