Original Real-Time Observations of Aeolian Vibrations on Power-Line Conductors

被引:17
|
作者
Godard, Bertrand [1 ]
Guerard, Suzanne [1 ]
Lilien, Jean-Louis [1 ]
机构
[1] Univ Liege, Dept Elect Elect & Comp Sci, B-4000 Liege, Belgium
关键词
Aeolian vibrations; conductor vibration measurement; frequency measurement; transmission lines; wind;
D O I
10.1109/TPWRD.2011.2158859
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Measurements of overhead conductor vibration, caused by Von Karman vortex shedding, were carried out with a new experimental device, developed by the authors, capable of continuous monitoring of acceleration over a wide range of frequency and amplitude. Continuous real-time observations showed the important influence of wind direction and turbulence as well as some divergence in predictions of the Strouhal equation.
引用
收藏
页码:2111 / 2117
页数:7
相关论文
共 50 条
  • [1] Aeolian Vibrations on Power-Line Conductors, Evaluation of Actual Self Damping
    Guerard, Suzanne
    Godard, Bertrand
    Lilien, Jean-Louis
    IEEE TRANSACTIONS ON POWER DELIVERY, 2011, 26 (04) : 2118 - 2122
  • [2] GALLOPING OF BUNDLED POWER-LINE CONDUCTORS
    NAKAMURA, Y
    JOURNAL OF SOUND AND VIBRATION, 1980, 73 (03) : 363 - 377
  • [3] METHOD FOR REAL-TIME ADAPTIVE CANCELLING OF POWER-LINE NOISE BY MICROPROCESSOR.
    Kubo, Hiroshi
    Uematsu, Hitoshi
    Takemoto, Akira
    Nakagawa, Takeshi
    Electronics and Communications in Japan, Part II: Electronics (English translation of Denshi Tsushin Gakkai Ronbunshi), 1987, 70 (02): : 53 - 61
  • [4] An instrument for real-time emulation of multipath fading in indoor power-line networks
    Anastasiadou, D
    Sawopoulos, P
    Antonakopoulos, T
    IMTC/O3: PROCEEDINGS OF THE 20TH IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1 AND 2, 2003, : 573 - 578
  • [5] On the Euler-Lagrange formalism to compute power line bundle conductors subject to aeolian vibrations
    Kubelwa, Y. D.
    Swanson, A. G.
    Papailiou, K. O.
    Dorrell, D. G.
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2022, 163
  • [6] Aeolian Vibrations of Transmission Line Conductors with More than One Damper
    Rezaei, A.
    Sadeghi, M. H.
    INTERNATIONAL JOURNAL OF ENGINEERING, 2015, 28 (10): : 1515 - 1524
  • [7] Time Synchronization in Power-line Communication
    Stastny, Ladislav
    Franek, Lesek
    Jirgl, Miroslav
    Misik, Stefan
    Bradac, Zdenek
    IFAC PAPERSONLINE, 2015, 48 (04): : 83 - 88
  • [8] Real-Time Ethernet over Power Line
    Lopes, Joao
    Planells, Jose Puche
    Verl, Alexander
    PROCEEDINGS OF THE 2018 25TH INTERNATIONAL CONFERENCE ON MECHATRONICS AND MACHINE VISION IN PRACTICE (M2VIP), 2018, : 272 - 277
  • [9] Adjusting power line sag in real-time
    Wagner, Mary Jo
    Power, 2019, 163 (01)
  • [10] SATELLITE-OBSERVATIONS OF POWER-LINE HARMONIC RADIATION
    BULLOUGH, K
    SPACE SCIENCE REVIEWS, 1983, 35 (02) : 175 - 183