Impact of tapered-cuff tracheal tube on microaspiration of gastric contents in intubated critically ill patients: a multicenter cluster-randomized cross-over controlled trial

被引:55
作者
Jaillette, Emmanuelle [1 ]
Girault, Christophe [2 ,3 ]
Brunin, Guillaume [4 ]
Zerimech, Farid [5 ]
Behal, Helene [6 ]
Chiche, Arnaud [7 ]
Broucqsault-Dedrie, Celine [8 ]
Fayolle, Cyril [9 ]
Minacori, Franck [10 ]
Alves, Isabelle [11 ]
Barrailler, Stephanie [12 ]
Labreuche, Julien [6 ]
Robriquet, Laurent [1 ]
Tamion, Fabienne [2 ,3 ]
Delaporte, Emmanuel [4 ]
Thellier, Damien [7 ]
Delcourte, Claire [1 ]
Duhamel, Alain [6 ]
Nseir, Saad [1 ,13 ]
机构
[1] CHU Lille, Crit Care Ctr, Rue E Laine, F-59037 Lille, France
[2] Rouen Univ, Rouen Univ Hosp, Dept Med Intens Care, Rouen, France
[3] Rouen Univ, Inst Biomed Res, UPRES IRIB EA 3830, Rouen, France
[4] CH Dr Duchenne, Reanimat Polyvalente, Allee Jacques Monod,BP 609, F-62321 Boulogne Sur Mer, France
[5] CHU Lille, Pole Biol Pathol Genet, Lab Biochim & Biol Mol, F-59000 Lille, France
[6] CHU Lille, Clin Sante Publ Plateforme Aide Methodol, F-59037 Lille, France
[7] Reanimat Med & Infect, 115 Rue President Coty, F-59208 Tourcoing, France
[8] CH Roubaix, Reanimat Polyvalente, Hop Victor Provo, 17 Bd Lacordaire,BP 359, F-59056 Roubaix, France
[9] CH Dunkerque, Serv Reanimat Polyvalente, 130 Ave Louis Herbeaux BP 6367, F-59140 Dunkerque, France
[10] CH St Philibert, Reanimat Polyvalente, 115 Rue Grand But,BP 249, F-59462 Lomme Les Lille, France
[11] CH Valenciennes, Reanimat Med, Ave Desandrouin,BP479, F-59322 Valenciennes, France
[12] CH Dr Schaffner, Reanimat Polyvalente, 99 Route La Bassee,BP8, F-62307 Lens, France
[13] Lille Univ, Med Sch, F-59000 Lille, France
关键词
Intubation; Tracheal cuff; Microaspiration; Ventilator-associated pneumonia; Ventilator-associated events; VENTILATOR-ASSOCIATED PNEUMONIA; ENDOTRACHEAL-TUBES; PRESSURE; METAANALYSIS; SHAPE; POLYURETHANE; PREVENTION; CARE; ICU;
D O I
10.1007/s00134-017-4736-x
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose: Studies on the impact of tapered-cuff tracheal tubes on rates of microaspiration and ventilator-associated pneumonia (VAP) in intubated patients have reported conflicting results. The aim of this study was to determine the influence of this shape of tracheal cuff on abundant microaspiration of gastric contents in critically ill patients. Methods: All patients intubated in the intensive care unit (ICU) and requiring mechanical ventilation for at least 48 h were eligible for this multicenter cluster-randomized controlled cross-over open-label study. The primary outcome was abundant microaspiration of gastric contents, defined by the presence of pepsin at significant level in >30% of tracheal aspirates. Quantitative measurement of pepsin and salivary amylase was performed in all tracheal aspirates during the 48 h following enrollment. Results: A total of 326 patients were enrolled in the ten participating ICUs (162 in the PVC tapered-cuff group and 164 in the standard-cuff group). Patient characteristics were similar in the two study groups. The proportion of patients with abundant microaspiration of gastric contents was 53.5% in the tapered-cuff and 51.0% in the standard-cuff group (odds ratio 1.14, 95% CI 0.72-1.82). While abundant microaspiration of oropharyngeal secretions was not significantly different (77.4 vs 68.6%, p = 0.095), the proportion of patients with tracheobronchial colonization was significantly lower (29.6 vs 43.3%, p = 0.01) in the tapered-cuff than in the standard-cuff group. No significant difference between the two groups was found for other secondary outcomes, including ventilator-associated events and VAP. Conclusions: This trial showed no significant impact of tapered-cuff tracheal tubes on abundant microaspiration of gastric contents.
引用
收藏
页码:1562 / 1571
页数:10
相关论文
共 39 条
  • [2] An In Vitro Study to Assess Determinant Features Associated With Fluid Sealing in the Design of Endotracheal Tube Cuffs and Exerted Tracheal Pressures
    Bassi, Gianluigi Li
    Ranzani, Otavio Tavares
    Marti, Joan Daniel
    Giunta, Valeria
    Luque, Nestor
    Isetta, Valentina
    Ferrer, Miquel
    Farre, Ramon
    Pimentel, Guilherme Leite
    Torres, Antoni
    [J]. CRITICAL CARE MEDICINE, 2013, 41 (02) : 518 - 526
  • [3] The value of polyurethane-cuffed endotracheal tubes to reduce microaspiration and intubation-related pneumonia: a systematic review of laboratory and clinical studies
    Blot, Stijn I.
    Rello, Jordi
    Koulenti, Despoina
    [J]. CRITICAL CARE, 2016, 20
  • [4] How to avoid microaspiration? A key element for the prevention of ventilator-associated pneumonia in intubated ICU patients
    Blot, Stijn I.
    Poelaert, Jan
    Kollef, Marin
    [J]. BMC INFECTIOUS DISEASES, 2014, 14
  • [5] Weaning from mechanical ventilation
    Boles, J-M.
    Bion, J.
    Connors, A.
    Herridge, M.
    Marsh, B.
    Melot, C.
    Pearl, R.
    Silverman, H.
    Stanchina, M.
    Vieillard-Baron, A.
    Welte, T.
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2007, 29 (05) : 1033 - 1056
  • [6] The Impact of Hospital-Wide Use of a Tapered-Cuff Endotracheal Tube on the Incidence of Ventilator-Associated Pneumonia
    Bowton, David L.
    Hite, R. Duncan
    Martin, R. Shayn
    Sherertz, Robert
    [J]. RESPIRATORY CARE, 2013, 58 (10) : 1582 - 1587
  • [7] Lost in Translation: Failure of Tracheal Tube Modifications to Impact Ventilator-associated Pneumonia
    Branson, Richard D.
    Hess, Dean R.
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2015, 191 (06) : 606 - 608
  • [8] Evaluation of an Automated Endotracheal Tube Cuff Controller During Simulated Mechanical Ventilation
    Chenelle, Christopher T.
    Oto, Jun
    Sulemanji, Demet
    Fisher, Daniel F.
    Kacmarek, Robert M.
    [J]. RESPIRATORY CARE, 2015, 60 (02) : 183 - 190
  • [9] Assessment of intraoperative microaspiration: does a modified cuff shape improve sealing?
    D'Haese, J.
    De Keukeleire, T.
    Remory, I.
    Van Rompaey, K.
    Umbrain, V.
    Poelaert, J.
    [J]. ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2013, 57 (07) : 873 - 880
  • [10] Effect of tracheal tube cuff shape on fluid leakage across the cuff: an in vitro study
    Dave, M. H.
    Frotzler, A.
    Spielmann, N.
    Madjdpour, C.
    Weiss, M.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2010, 105 (04) : 538 - 543