Gnana Laryngeal Airway in Clinical Practice: A Prospective Observational Study

被引:1
作者
Kapoor, Dheeraj [1 ]
Singh, Jasveer [1 ]
Mitra, Sukanya [1 ]
Viswanath, Omar [2 ,3 ,4 ]
Kaye, Alan David [5 ]
Urits, Ivan [6 ]
Orhurhu, Vwaire [6 ]
机构
[1] Govt Med Coll & Hosp, Dept Anaesthesia & Intens Care, Chandigarh, India
[2] Valley Anaesthesiol & Pain Consultants, Phoenix, AZ USA
[3] Creighton Univ, Sch Med, Phoenix Reg Campus, Phoenix, AZ USA
[4] Univ Arizona, Coll Med, Dept Anesthesiol, Phoenix, AZ USA
[5] Louisiana State Univ, Sch Med, Dept Anaesthesiol & Pharmacol Toxicol & Neurosci, Shreveport, LA USA
[6] Harvard Med Sch, Beth Israel Deaconess Med Ctr, Dept Anaesthesia Crit Care & Pain Med, Boston, MA 02115 USA
关键词
Compliance; ease of insertion; Gnana Laryngeal Airway; oropharyngeal leak pressure; peak airway pressure; resistance; MASK AIRWAY; EXTRAGLOTTIC AIRWAY; MANAGEMENT; PRESSURE; EFFICACY; HISTORY; DEVICES; SAFETY; SYSTEM; WORK;
D O I
10.5152/TJAR.2019.00243
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: The Gnana Laryngeal Airway (GLA) device, a novel supraglottic, airway device, is similar to the LMA-Classic in basic design, but with an additional suction port on the convex portion of the laryngeal mask to remove the saliva. We evaluated the GLA device in terms of ease and time to insertion, the number of attempts, oropharyngeal leak pressure (OLP), cornet placement, and complications in adult patients undergoing elective surgical procedures. Methods: After general anaesthesia, the GLA device was inserted in ASA Class I-H consecutive patients aged 18-60 years, who were scheduled for elective surgeries lasting <2h. An independent observer noted (1) 10 consecutive successful CAA device insertions, all on the first attempt: (2) 10 consecutive device insertions, each <20 second in duration; and (3) 10 consecutive patients with the mean leak <10%. The criteria were fulfilled in 50 consecutive patients. Results: In 72% of patients, the CAA device was successfully placed on the first attempt and was effortless in 64%. Between the first 10 and last 10 consecutive patients of the total 50, the ease-of-insertion grade progressively decreased (mean +/- standard deviation [SD]: 2.80 +/- 0.25 to 1.30 +/- 0.15, p<0.0001) and so did insertion time in seconds (28.70 +/- 1.87 to 14.20 +/- 0.79, p<0.0001). The post-insertion, OLP and airway compliance progressively increased, while the cuff inflation volume, peak airway pressure and airway resistance progressively decreased, along with minimal side effects and malposition. Conclusion: The GLA device insertion became progressively easier and faster; thus, such a device is promising and warrants further clinical evaluation.
引用
收藏
页码:280 / 287
页数:8
相关论文
共 50 条
  • [31] Pilot study of the air-Q Intubating Laryngeal Airway in clinical use
    Bakker, E. J.
    Valkenburg, M.
    Galvin, E. M.
    ANAESTHESIA AND INTENSIVE CARE, 2010, 38 (02) : 346 - 348
  • [32] Comparison of the Laryngeal Mask Airway (CTrach™) and Direct Coupled Interface-Video Laryngoscope for Endotracheal Intubation: a Prospective, Randomized, Clinical Study
    Hosten, Tulay
    Gurkan, Yavuz
    Ozdamar, Dilek
    Tekin, Murat
    Solak, Mine
    Toker, Kamil
    BALKAN MEDICAL JOURNAL, 2012, 29 (03) : 268 - 272
  • [33] Clinical experiences with a new system for automated hand hygiene monitoring: A prospective observational study
    Iversen, Anne-Mette
    Kavalaris, Christiane Pahl
    Hansen, Rosa
    Hansen, Marco Bo
    Alexander, Rebekah
    Kostadinov, Krassimir
    Holt, Jette
    Kristensen, Brian
    Knudsen, Jenny Dahl
    Moller, Jens Kjolseth
    Ellermann-Eriksen, Svend
    AMERICAN JOURNAL OF INFECTION CONTROL, 2020, 48 (05) : 527 - 533
  • [34] Comparison of the Supraglottic Airway Devices Classic, Fastrach and Supreme Laryngeal Mask Airway: A Prospective Randomised Clinical Trial of Efficacy, Safety and Complications
    Komur, Erdal
    Bakan, Nurten
    Tomruk, Senay Goksu
    Karaoren, Gulsah
    Dogan, Zelin Topac
    TURKISH JOURNAL OF ANAESTHESIOLOGY AND REANIMATION, 2015, 43 (06) : 406 - 411
  • [35] Influence of head position and neuromuscular block on the clinical efficacy of supraglottic airway devices. A prospective randomized study to compare the laryngeal tube suction (LT™) with the ProSeal™ laryngeal mask
    Mann, V.
    Mann, S. T. W.
    Rupp, D.
    Roehrig, R.
    Weigand, M. A.
    Mueller, M.
    NOTFALL & RETTUNGSMEDIZIN, 2012, 15 (02): : 136 - 141
  • [36] Comparisons of clinical performance of guardian laryngeal mask with laryngeal mask airway ProSeal
    Pajiyar, Ajay Kumar
    Wen, Zhiting
    Wang, Haiyun
    Ma, Lin
    Miao, Lumin
    Wang, Guolin
    BMC ANESTHESIOLOGY, 2015, 15
  • [37] Techniques for the insertion of the proseal laryngeal mask airway: comparison of the foley airway stylet tool with the introducer tool in a prospective, randomized study
    Chen, Mao-Kai
    Hsu, Hung-Te
    Lu, I-Cheng
    Shih, Chih-Kai
    Shen, Ya-Chun
    Tseng, Kuang-Yi
    Cheng, Kuang-I
    BMC ANESTHESIOLOGY, 2014, 14
  • [38] Comparison of videolaryngoscope-guided versus standard digital insertion techniques of the ProSeal™ laryngeal mask airway: a prospective randomized study
    Ozgul, Ulku
    Erdil, Feray Akgul
    Erdogan, Mehmet Ali
    Begec, Zekine
    Colak, Cemil
    Yucel, Aytac
    Durmus, Mahmut
    BMC ANESTHESIOLOGY, 2019, 19 (01)
  • [39] Comparison of the third-generation streamlined liner of the pharynx airway (SLIPA-3G) with the laryngeal mask airway supreme for laparoscopic cholecystectomy: a randomized prospective study
    Fan, Hongna
    Li, Lin
    Zhu, Lei
    Yi, Zhuo
    Diao, Yugang
    BMC ANESTHESIOLOGY, 2022, 22 (01)
  • [40] Epidemiology of uterine myomas and clinical practice in Spain: An observational study
    Monleon, Javier
    Luisa Canete, Maria
    Caballero, Virginia
    del Campo, Manuel
    Domenec, Alejandro
    Angel Losada, Miguel
    Calaf, Joaquim
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2018, 226 : 59 - 65