Ion-recombination correction for different ionization chambers in high dose rate flattening-filter-free photon beams

被引:33
作者
Lang, Stephanie [1 ]
Hrbacek, Jan [1 ]
Leong, Aidan [1 ]
Kloeck, Stephan [1 ]
机构
[1] Univ Zurich Hosp, Dept Radiat Oncol, CH-8901 Zurich, Switzerland
关键词
GENERAL COLLECTION EFFICIENCY; LIQUID ISOOCTANE; SATURATION CORRECTION; PLANE-PARALLEL; PULSED PHOTON; ELECTRON; TETRAMETHYLSILANE; YIELD;
D O I
10.1088/0031-9155/57/9/2819
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Recently, there has been an increased interest in flattening-filter-free (FFF) linear accelerators. Removal of the filter results in available dose rates up to 24 Gy min(-1) (for nominal energy 10 MV in depth of maximum dose, a source-surface distance of 100 cm and a field size of 10 x 10 cm(2)). To guarantee accurate relative and reference dosimetry for the FFF beams, we investigated the charge collection efficiency of multiple air-vented and one liquid ionization chamber for dose rates up to 31.9 Gy min(-1). For flattened beams, the ion-collection efficiency of all air-vented ionization chambers (except for the PinPoint chamber) was above 0.995. By removing the flattening filter, we found a reduction in collection efficiency of approximately 0.5-0.9% for a 10 MV beam. For FFF beams, the Markus chamber showed the largest collection efficiency of 0.994. The observed collection efficiencies were dependent on dose per pulse, but independent of the pulse repetition frequency. Using the liquid ionization chamber, the ion-collection efficiency for flattened beams was above 0.990 for all dose rates. However, this chamber showed a low collection efficiency of 0.940 for the FFF 10 MV beam at a dose rate of 31.9 Gy min(-1). All investigated air-vented ionization chambers can be reliably used for relative dosimetry of FFF beams. The order of correction for reference dosimetry is given in the manuscript. Due to their increased saturation in high dose rate FFF beams, liquid ionization chambers appear to be unsuitable for dosimetry within these contexts.
引用
收藏
页码:2819 / 2827
页数:9
相关论文
共 23 条
[1]   Response to high-energy photons of PTW31014 PinPoint ion chamber with a central aluminum electrode [J].
Agostinelli, S. ;
Garelli, S. ;
Piergentili, M. ;
Foppiano, F. .
MEDICAL PHYSICS, 2008, 35 (07) :3293-3301
[2]   AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams [J].
Almond, PR ;
Biggs, PJ ;
Coursey, BM ;
Hanson, WF ;
Huq, MS ;
Nath, R ;
Rogers, DWO .
MEDICAL PHYSICS, 1999, 26 (09) :1847-1870
[3]  
[Anonymous], IONIZATION CHAMBERS
[4]   CURRENT COLLECTION AND IONIC RECOMBINATION IN SMALL CYLINDRICAL IONIZATION CHAMBERS EXPOSED TO PULSED RADIATION [J].
BOAG, JW ;
CURRANT, J .
BRITISH JOURNAL OF RADIOLOGY, 1980, 53 (629) :471-478
[5]   Determination of the recombination correction factor kS for some specific plane-parallel and cylindrical ionization chambers in pulsed photon and electron beams [J].
Bruggmoser, G. ;
Saum, R. ;
Schmachtenberg, A. ;
Schmid, F. ;
Schuele, E. .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (02) :N35-N50
[6]   SATURATION CORRECTION FOR THE NE 2560/1 DOSIMETER IN PHOTON DOSIMETRY [J].
BURNS, JE ;
ROSSER, KE .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (05) :687-693
[7]   The characterization of unflattened photon beams from a 6 MV linear accelerator [J].
Cashmore, Jason .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (07) :1933-1946
[8]   Liquid ionization chamber measurements of dose distributions in small 6 MV photon beams [J].
Dasu, A ;
Lofroth, PO ;
Wickman, G .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (01) :21-36
[9]   Saturation current and collection efficiency for ionization chambers in pulsed beams [J].
DeBlois, F ;
Zankowski, C ;
Podgorsak, EB .
MEDICAL PHYSICS, 2000, 27 (05) :1146-1155
[10]   MEASUREMENT OF SATURATION CORRECTION FACTORS OF THIMBLE-TYPE IONIZATION CHAMBERS IN PULSED PHOTON BEAMS [J].
DERIKUM, K ;
ROOS, M .
PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (06) :755-763