Load Dispersion Effects of Acetabular Reinforcement Devices Used in Revision Total Hip Arthroplasty A Simulation Study Using Finite Element Analysis

被引:31
作者
Kawanabe, Keiichi [1 ,2 ]
Akiyama, Haruhiko [2 ]
Goto, Koji [2 ]
Maeno, Sumihiko [3 ]
Nakamura, Takashi [2 ]
机构
[1] Kobe City Med Ctr Gen Hosp, Dept Orthopaed Surg, Chuo Ku, Kobe, Hyogo 6500046, Japan
[2] Kyoto Univ, Dept Orthopaed Surg, Kyoto, Japan
[3] Japan Med Mat Co Ltd, Osaka, Japan
关键词
load dispersion effect; acetabular reinforcement device; revision total hip arthroplasty; finite element analysis; FOLLOW-UP; STRUCTURAL ALLOGRAFT; BONE-GRAFT; RECONSTRUCTION; MANAGEMENT; FAILURE; DEFICIENCIES; COMPONENTS; DEFECTS; RING;
D O I
10.1016/j.arth.2011.04.019
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Several types of acetabular reinforcement devices are used to prevent the collapse of grafted bone in revision total hip arthroplasty. However, it remains unclear how the stress is reduced by different devices. We used finite element analysis to evaluate 4 types of acetabular reinforcement devices: Kerboull-type device, Burch-Schneider anti-protrusio cage, Mueller ring, and Ganz ring. The control was a socket fixed with bone cement without any reinforcement devices. The stress distribution on the inner surface of each socket was calculated by binarization image processing. For all 4 reinforcement devices, the stress was reduced to less than one-half of that in the control. All the devices were useful for preventing the collapse of bulk bone grafts applied to load-bearing defects.
引用
收藏
页码:1061 / 1066
页数:6
相关论文
共 26 条
[1]  
Asada K, 1997, BIOMECHANICS ORTHOPE, V347, P347
[2]   REVISION ARTHROPLASTY USING AN ANTI-PROTRUSIO CAGE FOR MASSIVE ACETABULAR BONE DEFICIENCY [J].
BERRY, DJ ;
MULLER, ME .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (05) :711-715
[3]  
DANTONIO JA, 1989, CLIN ORTHOP RELAT R, P126
[4]   Revision of the acetabular component of a total hip arthroplasty with a massive structural allograft - Study with a minimum five-year follow-up [J].
Garbuz, D ;
Morsi, E ;
Gross, AE .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (05) :693-697
[5]   Ganz reinforcement ring for reconstruction of acetabular defects in revision total hip arthroplasty [J].
Gerber, A ;
Pisan, M ;
Zurakowski, D ;
Isler, B .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (12) :2358-2364
[6]   The management of severe acetabular bone loss using structural allograft and acetabular reinforcement devices [J].
Gill, TJ ;
Sledge, JB ;
Müller, ME .
JOURNAL OF ARTHROPLASTY, 2000, 15 (01) :1-7
[7]  
HARRIS WH, 1993, ORTHOP CLIN N AM, V24, P663
[8]  
Hayashi K, 1993, SUMMARY BIOMECHANICS, P46
[9]  
Hobatho MC, 1997, ST HEAL T, V40, P157
[10]   FAILURE OF STRUCTURAL ACETABULAR ALLOGRAFTS IN CEMENTLESS REVISION HIP-ARTHROPLASTY [J].
HOOTEN, JP ;
ENGH, CA ;
ENGH, CA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (03) :419-422