Advanced Monte Carlo simulator of the polarization-sensitive optical coherence tomography systems

被引:1
作者
Kraszewski, Maciej [1 ]
Trojanowski, Michal [1 ]
Plucinski, Jerzy [1 ]
Strakowski, Marcin R. [1 ]
机构
[1] Gdansk Univ Technol, Fac Elect Telecommun & Informat, Gdansk, Poland
来源
BIOMEDICAL APPLICATIONS OF LIGHT SCATTERING IX | 2015年 / 9333卷
关键词
optical coherence tomography; spectroscopy; spectral imaging; digital signal processing; SCATTERING MEDIA; TURBID MEDIA; TISSUE; LIGHT;
D O I
10.1117/12.2079739
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Simulations of the optical coherence tomography (OCT) systems using the Monte Carlo method is a widely explored research area. However, there are several difficulties that need to be overcome in order to properly model the OCT imaging with the Monte Carlo algorithm. First of all the temporal and the spatial coherence of the scattered light need to be considered, since OCT is based on the interference phenomenon. For the same reason, the polarization state of the scattered light need to be calculated. Moreover, the OCT systems use light beams that can be described by the Gaussian beam model. However, such beams cannot be directly simulated using the standard Monte Carlo algorithm. Different research groups have developed simulators dealing with some of these problems but the Monte Carlo simulator which considers all of them has not been published yet. Here we present the Monte Carlo program allowing to simulate OCT images of heterogeneous light scattering structures. The presented program considers all of the listed problems and allows to model complex sample geometries with layer boundaries described by a set of polygons.
引用
收藏
页数:10
相关论文
共 19 条
[1]   Advanced modelling of optical coherence tomography systems [J].
Andersen, PE ;
Thrane, L ;
Yura, HT ;
Tycho, A ;
Jorgensen, TM ;
Frosz, MH .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (07) :1307-1327
[2]  
[Anonymous], 2008, OPTICAL COHERENCE TO
[3]   Robust concentration determination of optically active molecules in turbid media with validated three-dimensional polarization sensitive Monte Carlo calculations [J].
Côté, D ;
Vitkin, IA .
OPTICS EXPRESS, 2005, 13 (01) :148-163
[4]   Quantitative measurement of attenuation coefficients of weakly scattering media using optical coherence tomography [J].
Faber, DJ ;
van der Meer, FJ ;
Aalders, MCG ;
van Leeuwen, TG .
OPTICS EXPRESS, 2004, 12 (19) :4353-4365
[5]  
Germer T.A., 2008, SCATMECH: Polarized Light Scattering C++ Class Library
[6]   Monte Carlo modeling of angiographic optical coherence tomography [J].
Hartinger, Alzbeta E. ;
Nam, Ahhyun S. ;
Chico-Calero, Isabel ;
Vakoc, Benjamin J. .
BIOMEDICAL OPTICS EXPRESS, 2014, 5 (12) :4338-4349
[7]   Simulation of optical coherence tomography images by Monte Carlo modeling based on polarization vector approach [J].
Kirillin, Mikhail ;
Meglinski, Igor ;
Kuzmin, Vladimir ;
Sergeeva, Ekaterina ;
Myllyla, Risto .
OPTICS EXPRESS, 2010, 18 (21) :21714-21724
[8]   Contrasting properties of gold nanoshells and titanium dioxide nanoparticles for optical coherence tomography imaging of skin: Monte Carlo simulations and in vivo study [J].
Kirillin, Mikhail ;
Shirmanova, Marina ;
Sirotkina, Marina ;
Bugrova, Marina ;
Khlebtsov, Boris ;
Zagaynova, Elena .
JOURNAL OF BIOMEDICAL OPTICS, 2009, 14 (02)
[9]   Monte Carlo simulation of optical clearing of paper in optical coherence tomography [J].
Kirillin, MY ;
Priezzhev, A ;
Hast, J ;
Myllylä, R .
QUANTUM ELECTRONICS, 2006, 36 (02) :174-180
[10]   Novel approach to modeling spectral-domain optical coherence tomography with Monte Carlo method [J].
Kraszewski, Maciej ;
Trojanowski, Michal ;
Strakowski, Marcin ;
Plucinski, Jerzy ;
Kosmowski, Bogdan B. .
OPTICAL MODELLING AND DESIGN III, 2014, 9131