Reproducibility of registration-based measures of lung tissue expansion

被引:59
作者
Du, Kaifang [1 ]
Bayouth, John E. [2 ]
Cao, Kunlin [3 ]
Christensen, Gary E. [2 ,3 ]
Ding, Kai [4 ]
Reinhardt, Joseph M. [1 ]
机构
[1] Univ Iowa, Dept Biomed Engn, Iowa City, IA 52242 USA
[2] Univ Iowa, Dept Radiat Oncol, Iowa City, IA 52242 USA
[3] Univ Iowa, Dept Elect & Comp Engn, Iowa City, IA 52242 USA
[4] Univ Virginia Hlth Syst, Dept Radiat Oncol, Charlottesville, VA 22908 USA
基金
美国国家卫生研究院;
关键词
variability; image registration; lung expansion; regional pulmonary function; COMPUTED-TOMOGRAPHY; VENTILATION; CT; IMAGES; VOLUME; ARTIFACTS; DENSITY; MAPS; MRI;
D O I
10.1118/1.3685589
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Lung function depends on lung expansion and contraction during the respiratory cycle. Respiratory-gated CT imaging and 3D image registration can be used to locally estimate lung tissue expansion and contraction (regional lung volume change) by computing the determinant of the Jacobian matrix of the image registration deformation field. In this study, the authors examine the reproducibility of Jacobian-based measures of lung tissue expansion in two repeat 4DCT acquisitions of mechanically ventilated sheep and free-breathing humans. Methods: 4DCT image data from three white sheep and nine human subjects were used for this analysis. In each case, two 4DCT studies were acquired for each subject within a short time interval. The animal subjects were anesthetized and mechanically ventilated, while the humans were awake and spontaneously breathing based on respiratory pacing audio cues. From each 4DCT data set, an image pair consisting of a volume reconstructed near end inspiration and a volume reconstructed near end exhalation was selected. The end inspiration and end exhalation images were registered using a tissue volume preserving deformable registration algorithm and the Jacobian of the registration deformation field was used to measure regional lung expansion. The Jacobian map from the baseline data set was compared to the Jacobian map from the followup data by measuring the voxel-by-voxel Jacobian ratio. Results: In the animal subjects, the mean Jacobian ratio (baseline scan Jacobian divided by followup scan Jacobian, voxel-by-voxel) was 0.99846 +/- 0.021 (mean +/- standard deviation, averaged over the entire lung region). The mean Jacobian ratio was 1.02246 +/- 0.058 in the human subjects. The reproducibility of the Jacobian values was found to be strongly dependent on the reproducibility of the subject's respiratory effort and breathing pattern. Conclusions: Lung expansion, a surrogate for lung function, can be assessed using two or more respiratory-gated CT image acquisitions. The results show that good reproducibility can be obtained in anesthetized, mechanically ventilated animals, but variations in respiratory effort and breathing patterns reduce reproducibility in spontaneously-breathing humans. The global linear normalization can globally compensate for breathing effort differences, but a homogeneous scaling does not account for differences in regional lung expansion rates. Additional work is needed to develop compensation procedures or normalization schemes that can account for local variations in lung expansion during respiration. (C) 2012 American Association of Physicists in Medicine. [DOI: 10.1118/1.3685589]
引用
收藏
页码:1595 / 1608
页数:14
相关论文
共 34 条
[1]  
Adler J., 2010, R NUTSHELL
[2]  
Cao K., 2010, MED IMAGE ANAL CLIN
[3]   Tissue Volume and Vesselness Measure Preserving Nonrigid Registration of Lung CT Images [J].
Cao, Kunlin ;
Ding, Kai ;
Christensen, Gary E. ;
Reinhardt, Joseph M. .
MEDICAL IMAGING 2010: IMAGE PROCESSING, 2010, 7623
[4]   Ventilation from four-dimensional computed tomography: density versus Jacobian methods [J].
Castillo, Richard ;
Castillo, Edward ;
Martinez, Josue ;
Guerrero, Thomas .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (16) :4661-4685
[5]   Differences in regional wash-in and wash-out time constants for xenon-CT ventilation studies [J].
Chon, D ;
Simon, BA ;
Beck, KC ;
Shikata, H ;
Saba, OI ;
Won, CH ;
Hoffman, EA .
RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2005, 148 (1-2) :65-83
[6]  
Ding K., 2010, Medical Image Analysis for the Clinic: A Grand Challenge, P49
[7]   4DCT-based measurement of changes in pulmonary function following a course of radiation therapy [J].
Ding, Kai ;
Bayouth, John E. ;
Buatti, John M. ;
Christensen, Gary E. ;
Reinhardt, Joseph M. .
MEDICAL PHYSICS, 2010, 37 (03) :1261-1272
[8]   Characterization and identification of spatial artifacts during 4D-CT imaging [J].
Han, Dongfeng ;
Bayouth, John ;
Bhatia, Sudershan ;
Sonka, Milan ;
Wu, Xiaodong .
MEDICAL PHYSICS, 2011, 38 (04) :2074-2087
[9]   Visualizing lung function with positron emission tomography [J].
Harris, R. Scott ;
Schuster, Daniel P. .
JOURNAL OF APPLIED PHYSIOLOGY, 2007, 102 (01) :448-458
[10]   ESTIMATION OF REGIONAL PLEURAL SURFACE EXPANSILE FORCES IN INTACT DOGS [J].
HOFFMAN, EA ;
BEHRENBECK, T ;
CHEVALIER, PA ;
WOOD, EH .
JOURNAL OF APPLIED PHYSIOLOGY, 1983, 55 (03) :935-948