A prospective multicenter study to compare the precision of posttraumatic internal orbital reconstruction with standard preformed and individualized orbital implants

被引:121
作者
Zimmerer, Rueddiger M. [1 ]
Ellis, Edward, III [2 ]
Sanchez Aniceto, Gregorio [3 ]
Schramm, Alexander [4 ]
Wagner, Maximilian E. H. [1 ,11 ]
Grant, Michael P. [5 ]
Cornelius, Carl-Peter [6 ]
Strong, Edward Bradley [7 ]
Rana, Majeed [1 ]
Chye, Lim Thiam [8 ]
Rivero Calle, Alvaro [3 ]
Wilde, Frank [4 ]
Perez, Daniel [2 ]
Tavassol, Frank [1 ]
Bittermann, Gido [9 ]
Mahoney, Nicholas R. [5 ]
Redondo Alamillos, Marta [3 ]
Basic, Joanna [4 ]
Dittmann, Jan [1 ]
Rasse, Michael [10 ]
Gellrich, Nils-Claudius [1 ]
机构
[1] Hannover Med Sch, Mund Kiefer & Gesichtschirurg, Carl Neubergstr 1, D-30625 Hannover, Germany
[2] Univ Texas Hlth Sci Ctr San Antonio, Dept Oral & Maxillofacial Surg, 7703 Floyd Curl Dr, San Antonio, TX 78229 USA
[3] 12 Octubre Univ Hosp, Cirurgia Maxillofacial, Ave Cordoba S-N, Madrid 28041, Spain
[4] Bundeswehrkrankenhauses Ulm, Dept Oral Maxillofacial & Plast Facial Surg, Oberer Eselsberg 40, D-89081 Ulm, Germany
[5] Johns Hopkins Univ Hosp, Wilmer Eye Inst, 600 North Wolfe St, Baltimore, MD 21287 USA
[6] Klinikum LMU Muenchen, Klin & Poliklin Mund Kiefer & Gesichtschirurg, Lindwurmstr 2a, D-80337 Munich, Germany
[7] Univ Calif Davis, Dept Otolaryngol Head & Neck Surg, 2521 Stockton Blvd,Suite 7200, Sacramento, CA 95817 USA
[8] Natl Univ Singapore Hosp, Div Plast Surg, Lower Kent Ridge Rd, Singapore 119074, Singapore
[9] Univ Freiburg, Mund Kiefer & Gesichtschirurg, Hugstetter Str 55, D-79106 Freiburg, Germany
[10] Med Univ Klin Innsbruck, Univ Klin Mund Kiefer & Gesichtschirurg Zahn Mund, Anichstr 35, A-6020 Innsbruck, Austria
[11] Hannover Med Sch, Klin & Poliklin Mund Kiefer & Gesichtschirurg, Carl Neuberg Str 1, D-30625 Hannover, Germany
关键词
Orbital fracture; Blow-out fracture; Orbital implant; Intraoperative navigation; CAD/CAM; Comparative study; FLOOR FRACTURES; TITANIUM MESH; SECONDARY RECONSTRUCTION; BLOWOUT FRACTURES; NAVIGATION; ACCURACY; DIPLOPIA; REPAIR;
D O I
10.1016/j.jcms.2016.07.014
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: A variety of implants are available for orbital reconstruction. Titanium orbital mesh plates are available either as standard preformed implants or able to be individualized for the patient. The aim of this study was to analyze whether individualized orbital implants allow a more precise reconstruction of the orbit than standard preformed implants. Materials and methods: A total of 195 patients treated between 2010 and 2014 were followed up to 12 weeks after surgery. Of the patients, 100 had received standardized preformed and 95 individualized implants. The precision of orbital reconstruction with the different implants was determined by comparing the variances in the volume difference between the reconstructed and the contralateral orbit on the postoperative computed tomographic scans. Clinical volume-related parameters including globe position, vision, motility, and diplopia and surgical details including approach, timing and technique of implant modification, use of navigation, duration of surgery, as well as adverse events were documented. Results: Orbital reconstruction was significantly more precise when individualized implants were used. The same was seen with intraoperative navigation. An overlap in the use of individualized implants and navigation makes it difficult to attribute the improved precision to a single factor. Conclusion: This study demonstrated that individualization and navigation provide clinical benefit. (C) 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1485 / 1497
页数:13
相关论文
共 35 条
[1]   Diplopia and ocular motility in orbital blow-out fractures: 10-year retrospective study [J].
Alhamdani, Faaiz ;
Durham, Justin ;
Greenwood, Mark ;
Corbett, Ian .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2015, 43 (07) :1010-1016
[2]   Sports-related maxillofacial fractures over an 11-year period [J].
Antoun, Josepb S. ;
Lee, Kai H. .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2008, 66 (03) :504-508
[3]   Diplopia after surgical repair of orbital floor fractures [J].
Biesman, BS ;
Hornblass, A ;
Lisman, R ;
Kazlas, M .
OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 1996, 12 (01) :9-16
[4]   Pure orbital blowout fracture: New concepts and importance of medial orbital blowout fracture [J].
Burm, JS ;
Chung, CH ;
Oh, SJ .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1999, 103 (07) :1839-1849
[5]   An Analysis of 733 Surgically Treated Blowout Fractures [J].
Chi, Mi Jung ;
Ku, Myun ;
Shin, Kwang Hun ;
Baek, Sehyun .
OPHTHALMOLOGICA, 2010, 224 (03) :167-175
[6]  
CLINE RA, 1984, OPHTHALMOLOGY, V91, P229
[7]   Exophthalmometry: A comparative study of the Naugle and Hertel instruments [J].
Cole, HP ;
Couvillion, JT ;
Fink, AJ ;
Haik, BG ;
Kastl, PR .
OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 1997, 13 (03) :189-194
[8]  
Cruz Antonio Augusto V, 2004, Curr Opin Ophthalmol, V15, P416, DOI 10.1097/01.icu.0000136113.56288.87
[9]   Use of nonresorbable alloplastic implants for internal orbital reconstruction [J].
Ellis, E ;
Messo, E .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2004, 62 (07) :873-881
[10]   AN ANALYSIS OF 2,067 CASES OF ZYGOMATICO-ORBITAL FRACTURE [J].
ELLIS, E ;
ELATTAR, A ;
MOOS, KF .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1985, 43 (06) :417-428