Refrigerants used in the Portuguese food industry: Current status

被引:30
作者
Cardoso, Bruno J. [1 ]
Lamas, Francisco B. [1 ]
Gaspar, Adelio R. [1 ]
Ribeiro, Jose B. [1 ]
机构
[1] Univ Coimbra, Dept Mech Engn, ADAI, LAETA, Polo 2,Rua Luis Reis Santos, P-3030788 Coimbra, Portugal
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2017年 / 83卷
关键词
Refrigeration systems; Food industry; ODP; GWP; Refrigerant replacement; LOW-GWP ALTERNATIVES; COMMERCIAL REFRIGERATION; DROP-IN; SUPERMARKET REFRIGERATION; HEAT-PUMP; THERMODYNAMIC PERFORMANCE; NATURAL REFRIGERANT; ENERGY PERFORMANCE; R404A; R22;
D O I
10.1016/j.ijrefrig.2017.07.013
中图分类号
O414.1 [热力学];
学科分类号
摘要
Owing to environmental problems arising from the use of refrigerants, first the ozone depletion and later the global warming, various refrigerants have been banned and their phaseout deadlines established through some international protocols, the Montreal and Kyoto Protocols being two of the most famous of such agreements. This paper intends to make a characterization of the most currently used refrigerants in the Portuguese food industry, through a sample of 148 companies gathered in a nationwide survey. It also aims to analyse not only the environmental impacts of these refrigerants, but also the restrictions that these companies may incur according to the EU Regulation No. 517/2014, such as maintenance and service bans or cap and phase-down on the supply. Finally, according to other research and tests reports, some possible replacements for two of the most commonly used refrigerants (R404A and R22) which are being phased down, are summarized. According to the research, there are some satisfactory mid-term and long-term alternatives available for R22 and R404A that have much lower GWP, allowing systems to achieve higher efficiencies and in turn, lower environmental impacts during their service life. (C) 2017 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:60 / 74
页数:15
相关论文
共 114 条
[1]  
[Anonymous], 2013, ANSI/ASHRAE Standard 34-2013
[2]  
[Anonymous], 2010, ASHRAE HDB REFR
[3]  
[Anonymous], 1998, REV EUR COMMUNITY IN
[4]  
[Anonymous], 2008, ASHRAE HDB HVAC SYST
[5]  
[Anonymous], 2013, ASHRAE HDB FUND
[6]  
APA, 2014, PORT NAT INV REP GRE, P1990
[7]   An experimental investigation of the global environmental impact of the R22 retrofit with R422D [J].
Aprea, Ciro ;
Maiorino, Angelo .
ENERGY, 2011, 36 (02) :1161-1170
[8]   Theoretical analysis of a vapour compression refrigeration system with R502, R404A and R507A [J].
Arora, Akhilesh ;
Kaushik, S. C. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (06) :998-1005
[9]  
Augusto G., 2007, 8 C IB ENG MEC
[10]   A review - Status of CO2 as a low temperature refrigerant: Fundamentals and R&D opportunities [J].
Bansal, Pradeep .
APPLIED THERMAL ENGINEERING, 2012, 41 :18-29