Aspects of operational conditions of a double gap prototype RPC for the CMS/LHC experiment

被引:16
作者
Ahn, SH
Amirikas, R
Bahk, SY
Baik, KM
Gapienko, VA
Hong, B [1 ]
Hong, SJ
Kim, JY
Kim, YJ
Kim, YU
Koo, DG
Lee, KS
Lee, SJ
Lim, IT
Nam, SK
Pac, MY
Park, S
Rhee, JT
Seo, SW
Sim, KS
机构
[1] Korea Univ, Dept Phys, Korea Detector Lab, Seoul 136701, South Korea
[2] Konkuk Univ, Inst Adv Phys, Seoul, South Korea
[3] Wonkwang Univ, Dept Phys, Iksan, South Korea
[4] Chonnam Natl Univ, Dept Phys, Kwangju, South Korea
[5] Cheju Natl Univ, Dept Phys, Cheju, South Korea
[6] Chungbuk Natl Univ, Dept Phys, Chungjoo, South Korea
[7] Seoul Natl Univ Educ, Dept Phys, Seoul, South Korea
[8] Seonam Univ, Dept Phys, Namwon, South Korea
[9] Kangwon Natl Univ, Dept Phys, Chunchon, South Korea
[10] Dongshin Univ, Dept Elect Engn, Naju, South Korea
关键词
double gap; RPC; CMS; SF6; water vapour;
D O I
10.1016/S0168-9002(01)00623-4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper presents the results from cosmic ray tests performed in the framework of R&D effort on the forward Resistive Plate Chamber (RPC) for CMS. A double gap RPC of dimensions 50 x 50 cm(2) with 2 mm gas gaps was tested, We report data on the use of tetrafluorethane-based gas mixture, with additions of water vapour and SF6. Effriciency, time resolution and cross-talk behaviour of the detector were investigated. (C) 2001 Elsevier Science B.V.All rights reserved.
引用
收藏
页码:447 / 454
页数:8
相关论文
共 10 条
[1]   An environmental safe gas mixture for resistive plate chambers operated at low pressure [J].
Abbrescia, M ;
Bisceglie, E ;
Iaselli, G ;
Natali, S ;
Pugliese, G ;
Romano, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 417 (01) :16-23
[2]   Beam test results on double-gap resistive plate chambers proposed for CMS experiment [J].
Abbrescia, M ;
Bruno, G ;
Colaleo, A ;
Iaselli, G ;
Lamanna, G ;
Loddo, F ;
Maggi, M ;
Marangelli, B ;
Natali, S ;
Nuzzo, S ;
Pugliese, G ;
Ranieri, A ;
Romano, F ;
Gianini, G ;
Ratti, SP ;
Vitulo, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 414 (2-3) :135-148
[3]   Properties of C2H2F4-based gas mixture for avalanche mode operation of resistive plate chambers [J].
Abbrescia, M ;
Colaleo, A ;
Iaselli, G ;
Maggi, M ;
Marangelli, B ;
Natali, S ;
Nuzzo, S ;
Ranieri, A ;
Romano, F ;
Gianini, G ;
Ratti, SP ;
Vitulo, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 398 (2-3) :173-179
[4]   Recent results and developments on double-gap RPCs for CMS [J].
Abbrescia, M ;
Colaleo, A ;
Iaselli, G ;
Loddo, F ;
Maggi, M ;
Marangelli, B ;
Natali, S ;
Nuzzo, S ;
Pugliese, G ;
Ranieri, A ;
Romano, F ;
Gianini, G ;
Ratti, SP ;
Vitulo, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 409 (1-3) :43-45
[5]   Temperature and humidity dependence of bulk resistivity of bakelite for resistive plate chambers in CMS [J].
Ahn, SH ;
Amirikas, R ;
Bahk, SY ;
Gapienko, VA ;
Hong, B ;
Hong, SJ ;
Jung, SY ;
Kim, JY ;
Kim, YJ ;
Kim, YU ;
Koo, DG ;
Lee, KS ;
Lee, SJ ;
Lee, YL ;
Lim, IT ;
Nam, SK ;
Pac, MY ;
Park, SK ;
Ra, YS ;
Rhee, JT ;
Seo, SW ;
Sim, KS .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 451 (03) :582-587
[6]   Beam test results of a large forward Resistive Plate Chamber for the CMS/LHC [J].
Ahn, SH ;
Bahk, SY ;
Choi, JH ;
Hong, B ;
Hong, SJ ;
Kim, YJ ;
Kim, JY ;
Kim, SJ ;
Kim, YU ;
Koo, DK ;
Lee, SJ ;
Lee, KS ;
Lim, IT ;
Nam, SK ;
Pac, MY ;
Park, SK ;
Rhee, JT ;
Sim, KS ;
Yang, JT .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 443 (01) :31-36
[7]  
*CMS, 1997, CERNLHCC9732 CMS
[8]   Measurement of drift velocity and amplification coefficient in C2H2F4-isobutane mixtures for avalanche-operated resistive-plate counters [J].
Colucci, A ;
Gorini, E ;
Grancagnolo, F ;
Primavera, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 425 (1-2) :84-91
[9]   THE WIDE-GAP RESISTIVE PLATE CHAMBER [J].
CROTTY, I ;
ZEBALLOS, EC ;
VALVERDE, JL ;
HATZIFOTIADOU, D ;
WILLIAMS, MCS ;
ZICHICHI, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 360 (03) :512-520
[10]   New developments on resistive plate chambers for high rate operation [J].
Czyrkowski, H ;
Cwiok, M ;
Dabrowski, R ;
Dominik, W ;
Gorski, M ;
Królikowski, J ;
Majewski, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 419 (2-3) :490-496