Sequential Proximal Optimizing Technique in Provisional Bifurcation Stenting With Everolimus-Eluting Bioresorbable Vascular Scaffold Fractal Coronary Bifurcation Bench for Comparative Test Between Absorb and XIENCE Xpedition

被引:21
作者
Derimay, Francois [1 ,2 ,3 ]
Souteyrand, Geraud [4 ]
Motreff, Pascal [4 ]
Guerin, Patrice [5 ]
Pilet, Paul [5 ]
Ohayon, Jacques [6 ]
Darremont, Olivier [7 ]
Rioufol, Gilles [1 ,2 ,3 ]
Finet, Gerard [1 ,2 ,3 ]
机构
[1] Cardiovasc Hosp, Dept Intervent Cardiol, Lyon, France
[2] Univ Lyon 1, Lyon, France
[3] INSERM U1060 CARMEN, Lyon, France
[4] CHU Clermont Ferrand, Dept Cardiol, Clermont Ferrand, France
[5] Inst Thorax, UMR 915, Cardiol, Nantes, France
[6] DynaCell, CNRS UMR 5525, Lab TIMC IMAG, Inst Ingn & Informat Sante, Grenoble, France
[7] Clin St Augustin, Bordeaux, France
关键词
bioresorbable vascular scaffold; coronary bifurcation; polymeric stent; provisional stenting; PERCUTANEOUS CORONARY; OUTCOMES;
D O I
10.1016/j.jcin.2016.04.021
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The aim of this fractal bifurcation bench study was to compare provisional bifurcation stenting with a "re-POT" sequence, comprising a proximal optimizing technique (POT), side branch inflation, and final POT, between a bioresorbable vascular scaffold (BVS) and a metallic stent. BACKGROUND Re-POT proved significantly better than kissing balloon inflation in maintaining circular geometry without overstretch in metal stents, while significantly reducing side branch ostium strut obstruction and global strut malapposition. This should be useful for BVSs, which are more easily breakable. METHODS Twenty left main-like and 20 left anterior descending-like fractal coronary bifurcation bench models used 10 each 2.5 x 24 mm and 3.5 x 24 mm Absorb (Ab) BVSs and 10 each 2.5 x 24 mm and 3.5 x 24 mm XIENCE Xpedition (XX) metal stents, implanted by re-POT, with optical coherence tomographic analysis at each step and micro-computed tomographic analysis of Ab devices to detect strut fracture. RESULTS With Ab devices, re-POT reduced percentage strut malapposition close to XX rates (0.8 +/- 0.7% vs. 0.0 +/- 0.0%, p < 0.05; 3.5 +/- 1.7% vs. 0.3 +/- 0.6%, p < 0.05), conserving proximal circularity (elliptical ratio, 1.04 vs. 1.03 and 1.04 vs. 1.04; p = NS). Mean post-re-POT proximal expansion was 0.6 +/- 0.1 mm (+21.6 +/- 2.1%) for 2.5-mm and 1.0 +/- 0.1 mm (+23.6 +/- 2.2%) for 3.5-mm Ab devices, with only 1 strut fracture (left anterior descending-like bench). Side branch ostium strut obstruction was greater with Ab scaffolds than XX stents: 41.1 +/- 9.4% versus 16.4 +/- 8.1% (p < 0.05) and 31.8 +/- 3.2% versus 10.0 +/- 5.3% (p < 0.05), respectively, for 2.5- and 3.5-mm scaffolds and stents. Ab scaffolds showed 2 +/- 1% moderate but significant late recoil as of 1 h, reaching 4 +/- 2% by 24 h (p < 0.05). CONCLUSIONS Re-POT optimized most Ab provisional bifurcation treatments, without fracture, respecting fractal geometry, and without exceeding 1.0-mm proximal differential diameter. (C) 2016 by the American College of Cardiology Foundation.
引用
收藏
页码:1397 / 1406
页数:10
相关论文
共 21 条
  • [1] Percutaneous coronary intervention with everolimus-eluting bioresorbable vascular scaffolds in routine clinical practice: early and midterm outcomes from the European multicentre GHOST-EU registry
    Capodanno, Davide
    Gori, Tommaso
    Nef, Holger
    Latib, Azeem
    Mehilli, Julinda
    Lesiak, Maciej
    Caramanno, Giuseppe
    Naber, Christoph
    Di Mario, Carlo
    Colombo, Antonio
    Capranzano, Piera
    Wiebe, Jens
    Araszkiewicz, Aleksander
    Geraci, Salvatore
    Pyxaras, Stelios
    Mattesini, Alessio
    Naganuma, Toru
    Muenzel, Thomas
    Tamburino, Corrado
    [J]. EUROINTERVENTION, 2015, 10 (10) : 1144 - 1153
  • [2] The Absorb Bioresorbable Vascular Scaffold in Coronary Bifurcations
    Dzavik, Vladimir
    Colombo, Antonio
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (01) : 81 - 88
  • [3] Everolimus-Eluting Bioresorbable Scaffolds for Coronary Artery Disease
    Ellis, Stephen G.
    Kereiakes, Dean J.
    Metzger, D. Christopher
    Caputo, Ronald P.
    Rizik, David G.
    Teirstein, Paul S.
    Litt, Marc R.
    Kini, Annapoorna
    Kabour, Ameer
    Marx, Steven O.
    Popma, Jeffrey J.
    McGreevy, Robert
    Zhang, Zhen
    Simonton, Charles
    Stone, Gregg W.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2015, 373 (20) : 1905 - 1915
  • [4] Comparative Analysis of Sequential Proximal Optimizing Technique Versus Kissing Balloon Inflation Technique in Provisional Bifurcation Stenting Fractal Coronary Bifurcation Bench Test
    Finet, Gerard
    Derimay, Francois
    Motreff, Pascal
    Guerin, Patrice
    Pilet, Paul
    Ohayon, Jacques
    Darremont, Olivier
    Rioufol, Gilles
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (10) : 1308 - 1317
  • [5] Structure-function relation in the coronary artery tree: from fluid dynamics to arterial bifurcations
    Finet, Gerard
    Huo, Yunlong
    Rioufol, Gilles
    Ohayon, Jacques
    Guerin, Patrice
    Kassab, Ghassan S.
    [J]. EUROINTERVENTION, 2010, 6 : J10 - J15
  • [6] Finet Gerard, 2008, EuroIntervention, V3, P490, DOI 10.4244/EIJV3I4A87
  • [7] Biodegradable vascular scaffold: is optimal expansion the key to minimising flow disturbances and risk of adverse events?
    Foin, Nicolas
    Torii, Ryo
    Mattesini, Alessio
    Wong, Philip
    Di Mario, Carlo
    [J]. EuroIntervention, 2015, 10 (10) : 1139 - 1142
  • [8] Bioresorbable Vascular Scaffolds Versus Metallic Stents in Patients With Coronary Artery Disease ABSORB China Trial
    Gao, Runlin
    Yang, Yuejin
    Han, Yaling
    Huo, Yong
    Chen, Jiyan
    Yu, Bo
    Su, Xi
    Li, Lang
    Kuo, Hai-Chien
    Ying, Shih-Wa
    Cheong, Wai-Fung
    Zhang, Yunlong
    Su, Xiaolu
    Xu, Bo
    Popma, Jeffery J.
    Stone, Gregg W.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (21) : 2298 - 2309
  • [9] Computational approaches for analyzing the mechanics of atherosclerotic plaques: A review
    Holzapfel, Gerhard A.
    Mulvihill, John J.
    Cunnane, Eoghan M.
    Walsh, Michael T.
    [J]. JOURNAL OF BIOMECHANICS, 2014, 47 (04) : 859 - 869
  • [10] Optimal diameter of diseased bifurcation segment: a practical rule for percutaneous coronary intervention
    Huo, Yunlong
    Finet, Gerard
    Lefevre, Thierry
    Louvard, Yves
    Moussa, Issam
    Kassab, Ghassan S.
    [J]. EUROINTERVENTION, 2012, 7 (11) : 1310 - 1316