Viscoelasticity-based Staging of Hepatic Fibrosis with Multifrequency MR Elastography

被引:185
作者
Asbach, Patrick [1 ]
Klatt, Dieter [1 ]
Schlosser, Beate [1 ]
Biermer, Michael [1 ]
Muche, Marion [1 ]
Rieger, Anja [1 ]
Loddenkemper, Christoph [1 ]
Somasundaram, Rajan [1 ]
Berg, Thomas [1 ]
Hamm, Bernd [1 ]
Braun, Juergen [1 ]
Sack, Ingolf [1 ]
机构
[1] Charite, Dept Radiol, D-10117 Berlin, Germany
关键词
MAGNETIC-RESONANCE ELASTOGRAPHY; LIVER FIBROSIS; TRANSIENT ELASTOGRAPHY; NONINVASIVE ASSESSMENT; DIAGNOSIS; ACCURACY; BEHAVIOR; BRAIN;
D O I
10.1148/radiol.10092489
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To analyze the dynamics of the shear modulus of the liver to assess the optimal driving frequency and to determine the diagnostic accuracy of generalized frequency-independent elasticity cutoff values for staging hepatic fibrosis. Materials and Methods: This institutional review board-approved prospective study included 16 healthy volunteers and 72 patients with biopsy-proved liver fibrosis. After obtaining written informed consent, imaging was performed at 1.5-T by using a motion-sensitized echo-planar imaging sequence. Wave excitation was performed by an actuator introducing a superposition of four frequencies (25.0, 37.5, 50.0, 62.5 Hz) of shear waves. The elasticity mu value and the structure geometry parameter alpha were calculated by using the two-parameter springpot model. The performance of magnetic resonance (MR) elastography in staging liver fibrosis was assessed with area under the receiver operating characteristic curve (AUROC) analysis and Spearman correlation analysis. Results: Elasticity increased with stage of fibrosis, with mean values as follows: for volunteers, 2.25 kPa +/- 0.43 (standard deviation); stage F1, 2.61 kPa +/- 0.43; stage F2, 3.00 kPa +/- 0.63; stage F3, 3.86 kPa +/- 0.61; and stage F4, 5.86 kPa +/- 1.22. Frequency-independent cutoff values derived for fibrosis and AUROC values, respectively, were as follows: stage F1 or higher, 2.84 kPa and 0.9128; stage F2 or higher, 3.18 kPa and 0.9244; stage F3 or higher, 3.32 kPa and 0.9744; and equivalent to stage F4, 4.21 kPa and 0.9931. The geometry of the tissue (alpha value) did not correlate with fibrosis. Frequencies of 50.0 Hz and 62.5 Hz displayed the highest diagnostic accuracy. Conclusion: The diagnostic performance of multifrequency MR elastography in determining the degree of hepatic fibrosis increases with stage of fibrosis. Metrics obtained at the higher frequencies provide better diagnostic performance compared with the lower frequencies. Results of the AUROC analysis demonstrate the high accuracy of frequency-independent cutoff values for staging higher grades of hepatic fibrosis. (C) RSNA, 2010
引用
收藏
页码:80 / 86
页数:7
相关论文
共 21 条
[1]   Assessment of liver viscoelasticity using multifrequency MR elastography [J].
Asbach, Patrick ;
Klatt, Dieter ;
Hamhaber, Uwe ;
Braun, Juergen ;
Somasundaram, Rajan ;
Hamm, Bernd ;
Sack, Ingolf .
MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (02) :373-379
[2]  
DESMET VJ, 1994, HEPATOLOGY, V19, P1513, DOI 10.1002/hep.1840190629
[3]   Performance of transient elastography for the staging of liver fibrosis: A meta-analysis [J].
Friedrich-Rust, Mireen ;
Ong, Mei-Fang ;
Martens, Swantje ;
Sarrazin, Christoph ;
Bojunga, Joerg ;
Zeuzem, Stefan ;
Herrmann, Eva .
GASTROENTEROLOGY, 2008, 134 (04) :960-974
[4]   Liver Fibrosis in Viral Hepatitis: Noninvasive Assessment with Acoustic Radiation Force Impulse Imaging versus Transient Elastography [J].
Friedrich-Rust, Mireen ;
Wunder, Katrin ;
Kriener, Susanne ;
Sotoudeh, Fariba ;
Richter, Swantje ;
Bojunga, Joerg ;
Herrmann, Eva ;
Poynard, Thierry ;
Dietrich, Christoph F. ;
Vermehren, Johannes ;
Zeuzem, Stefan ;
Sarrazin, Christoph .
RADIOLOGY, 2009, 252 (02) :595-604
[5]   Accuracy of liver stiffness measurement for the diagnosis of cirrhosis in patients with chronic liver diseases [J].
Ganne-Carrie, Nathahe ;
Ziol, Marianne ;
de Ledinghen, Victor ;
Douvin, Catherine ;
Marcellin, Patrick ;
Castera, Laurent ;
Dhumeaux, Daniel ;
Trinchet, Jean-Claude ;
Beaugrand, Michel .
HEPATOLOGY, 2006, 44 (06) :1511-1517
[6]   Liver fibrosis: non-invasive assessment with MR elastography [J].
Huwart, L ;
Peeters, F ;
Sinkus, R ;
Annet, L ;
Salameh, N ;
ter Beek, LC ;
Horsmans, Y ;
Van Beers, BE .
NMR IN BIOMEDICINE, 2006, 19 (02) :173-179
[7]   Assessment of the Solid-Liquid Behavior of the Liver for the Diagnosis of Diffuse Disease Using Magnetic Resonance Elastography [J].
Klatt, D. ;
Asbach, P. ;
Somasundaram, R. ;
Hamm, B. ;
Braun, J. ;
Sack, I. .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2008, 180 (12) :1104-1109
[8]   Noninvasive assessment of the rheological behavior of human organs using multifrequency MR elastography: a study of brain and liver viscoelasticity [J].
Klatt, Dieter ;
Hamhaber, Uwe ;
Asbach, Patrick ;
Braun, Juergen ;
Sack, Ingolf .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (24) :7281-7294
[9]   Factors of Accuracy of Transient Elastography (Fibroscan) for the Diagnosis of Liver Fibrosis in Chronic Hepatitis C [J].
Lucidarme, Damien ;
Foucher, Juliette ;
Le Bail, Brigitte ;
Vergniol, Julien ;
Castera, Laurent ;
Duburque, Clotilde ;
Forzy, Gerard ;
Filoche, Bernard ;
Couzigou, Patrice ;
de Ledinghen, Victor .
HEPATOLOGY, 2009, 49 (04) :1083-1089
[10]  
Meyers M.A., 1999, MECH BEHAV MAT, P98