Initial Results of Simultaneous PET/MRI Experiments with an MRI-Compatible Silicon Photomultiplier PET Scanner

被引:153
作者
Yoon, Hyun Suk [1 ,2 ,3 ]
Ko, Guen Bae [1 ,2 ]
Kwon, Sun Il [1 ,4 ]
Lee, Chan Mi [1 ,2 ]
Ito, Mikiko [1 ,3 ]
Song, In Chan [3 ,5 ]
Lee, Dong Soo [1 ,3 ,6 ]
Hong, Seong Jong [7 ]
Lee, Jae Sung [1 ,2 ,3 ,4 ,8 ]
机构
[1] Seoul Natl Univ, Coll Med, Dept Nucl Med, 28 Yungundong, Seoul 110744, South Korea
[2] Seoul Natl Univ, Coll Med, Dept Biomed Sci, Seoul 110744, South Korea
[3] Seoul Natl Univ, Inst Radiat Med, Med Res Ctr, Seoul 110744, South Korea
[4] Seoul Natl Univ, Interdisciplinary Program Radiat Appl Life Sci, Seoul 110744, South Korea
[5] Seoul Natl Univ, Coll Med, Dept Radiol, Seoul 110744, South Korea
[6] Seoul Natl Univ, Dept Mol Med & Biopharmaceut Sci, Seoul 110744, South Korea
[7] Eulji Univ, Dept Radiol Sci, Gyeonggi Do, South Korea
[8] Seoul Natl Univ, Dept Brain & Cognit Sci, Seoul 110744, South Korea
关键词
PET/MRI; MR-PET; silicon photomultiplier (SiPM); Geiger-mode APD (G-APD); hybrid imaging; POSITRON-EMISSION-TOMOGRAPHY; SOLID-STATE PHOTOMULTIPLIERS; FEASIBILITY; DETECTOR; SYSTEM;
D O I
10.2967/jnumed.111.097501
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The most investigated semiconductor photosensor for MRI-compatible PET detectors is the avalanche photodiode (APD). However, the silicon photomultiplier (SiPM), also called the Geiger-mode APD, is gaining attention in the development of the next generation of PET/MRI systems because the SiPM has much better performance than the APD. We have developed an MRI-compatible PET system based on multichannel SiPM arrays to allow simultaneous PET/MRI. Methods: The SiPM PET scanner consists of 12 detector modules with a ring diameter of 13.6 cm and an axial extent of 3.2 cm. In each detector module, 4 multichannel SiPM arrays (with 4 x 4 channels arranged in a 2 x 2 array to yield 8 x 8 channels) were coupled with 20 x 18 Lu1.9Gd0.1SiO5:Ce crystals (each crystal is 1.5 x 1.5 x 7 mm) and mounted on a charge division network for multiplexing 64 signals into 4 position signals. Each detector module was enclosed in a shielding box to reduce interference between the PET and MRI scanners, and the temperature inside the box was monitored for correction of the temperature-dependent gain variation of the SiPM. The PET detector signal was routed to the outside of the MRI room and processed with a field programmable gate array-based data acquisition system. MRI compatibility tests and simultaneous PET/MRI acquisitions were performed inside a 3-T clinical MRI system with 4-cm loop receiver coils that were built into the SiPM PET scanner. Interference between the imaging systems was investigated, and phantom and mouse experiments were performed. Results: No radiofrequency interference on the PET signal or degradation in the energy spectrum and flood map was shown during simultaneous PET/MRI. The quality of the MRI scans acquired with and without the operating PET showed only slight degradation. The results of phantom and mouse experiments confirmed the feasibility of this system for simultaneous PET/MRI. Conclusion: Simultaneous PET/MRI was possible with a multichannel SiPM-based PET scanner, with no radiofrequency interference on PET signals or images and only slight degradation of the MRI scans.
引用
收藏
页码:608 / 614
页数:7
相关论文
共 50 条
  • [21] Workflow in Simultaneous PET/MRI
    Barbosa, Felipe de Galiza
    von Schulthess, Gustav
    Veit-Haibach, Patrick
    [J]. SEMINARS IN NUCLEAR MEDICINE, 2015, 45 (04) : 332 - 344
  • [22] Spatial Distortion Correction and Crystal Identification for MRI-Compatible Position-Sensitive Avalanche Photodiode-Based PET Scanners
    Chaudhari, Abhijit J.
    Joshi, Anand A.
    Wu, Yibao
    Leahy, Richard M.
    Cherry, Simon R.
    Badawi, Ramsey D.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (03) : 549 - 556
  • [23] Performance evaluation of a PET insert for preclinical MRI in stand-alone PET and simultaneous PET-MRI modes
    Emvalomenos, Gaelle
    Trajanovska, Sofie
    Pham, Binh T. T.
    Doughty, Peter
    Burnet, Jerome
    Smith, Isabelle
    Garipov, Ruslan
    Gregoire, Marie-Claude
    Sunn, Nana
    McGrath, John
    Meikle, Steven R.
    [J]. EJNMMI PHYSICS, 2021, 8 (01)
  • [24] PET, MRI, and simultaneous PET/MRI in the development of diagnostic and therapeutic strategies for glioma
    Puttick, Simon
    Bell, Christopher
    Dowson, Nicholas
    Rose, Stephen
    Fay, Michael
    [J]. DRUG DISCOVERY TODAY, 2015, 20 (03) : 306 - 317
  • [25] Small animal simultaneous PET/MRI: initial experiences in a 9.4 T microMRI
    Maramraju, Sri Harsha
    Smith, S. David
    Junnarkar, Sachin S.
    Schulz, Daniela
    Stoll, Sean
    Ravindranath, Bosky
    Purschke, Martin L.
    Rescia, Sergio
    Southekal, Sudeepti
    Pratte, Jean-Francois
    Vaska, Paul
    LWoody, Craig
    Schlyer, David J.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (08) : 2459 - 2480
  • [26] Development of PET/MRI with insertable PET for simultaneous PET and MR imaging of human brain
    Jung, Jin Ho
    Choi, Yong
    Jung, Jiwoong
    Kim, Sangsu
    Lim, Hyun Keong
    Im, Ki Chun
    Oh, Chang Hyun
    Park, Hyun-wook
    Kim, Kyung Min
    Kim, Jong Guk
    [J]. MEDICAL PHYSICS, 2015, 42 (05) : 2354 - 2363
  • [27] Simultaneous PET/MRI in stroke: a case series
    Werner, Peter
    Saur, Dorothee
    Zeisig, Vilia
    Ettrich, Barbara
    Patt, Marianne
    Sattler, Bernhard
    Jochimsen, Thies
    Lobsien, Donald
    Meyer, Philipp M.
    Bergh, Florian Then
    Dreyer, Antje
    Boltze, Johannes
    Classen, Joseph
    Fritzsch, Dominik
    Hoffmann, Karl-Titus
    Sabri, Osama
    Barthel, Henryk
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2015, 35 (09) : 1421 - 1425
  • [28] MRI-Based Nonrigid Motion Correction in Simultaneous PET/MRI
    Chun, Se Young
    Reese, Timothy G.
    Ouyang, Jinsong
    Guerin, Bastien
    Catana, Ciprian
    Zhu, Xuping
    Alpert, Nathaniel M.
    El Fakhri, Georges
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (08) : 1284 - 1291
  • [29] Development of a PET Scanner for Simultaneously Imaging Small Animals with MRI and PET
    Thompson, Christopher J.
    Goertzen, Andrew L.
    Thiessen, Jonathan D.
    Bishop, Daryl
    Stortz, Greg
    Kozlowski, Piotr
    Retiere, Fabrice
    Zhang, Xuezhu
    Sossi, Vesna
    [J]. SENSORS, 2014, 14 (08) : 14654 - 14671
  • [30] Studies of the interactions of an MRI system with the shielding in a combined PET/MRI scanner
    Peng, Bo J.
    Walton, Jeffrey H.
    Cherry, Simon R.
    Willig-Onwuachi, Jacob
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (01) : 265 - 280