Analysis of Bisphenol A, Alkylphenols, and Alkylphenol Ethoxylates in NIST SRM 2585 and Indoor House Dust by Gas Chromatography-Tandem Mass Spectrometry (GC/MS/MS)

被引:7
|
作者
Fan, Xinghua [1 ]
Kubwabo, Cariton [1 ]
Wu, Fang [2 ]
Rasmussen, Pat E. [1 ]
机构
[1] Hlth Canada, Environm Hlth Sci & Res Bur, Hlth Environm & Consumer Safety Branch, 50 Colombine Driveway, Ottawa, ON K1A 0K9, Canada
[2] Minist Environm & Climate Change, 125 Resources Rd, Toronto, ON M9P 3V6, Canada
关键词
SEMIVOLATILE ORGANIC-COMPOUNDS; ENDOCRINE DISRUPTOR; NONYLPHENOL ALTERS; PRESCHOOL-CHILDREN; HUMAN EXPOSURE; HUMAN URINE; HUMAN-MILK; IN-VIVO; TRICLOSAN; TETRABROMOBISPHENOL;
D O I
10.5740/jaoacint.18-0071
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Ingestion of house dust has been demonstrated to be an important exposure pathway to several contaminants in young children. These compounds include bisphenol A (BPA), alkyiphenols (APs), and alkylphenol ethoxylates (APEOs). Analysis of these compounds in house dust is challenging because of the complex composition of the sample matrix. Objective: The objective was to develop a simple and sensitive method to measure BPA, APs, and APEOs in indoor house dust. Methods: An integrated method that involved solvent extraction using sonication, sample cleanup by solid-phase extraction, derivatization by 2,2,2-trifluoro-N-methyl-N-(trimethylsilyl)acetamide, and analysis by GC coupled with tandem MS was developed for the simultaneous determination of BPA, APs, and APEOs in NIST Standard Reference Material (SRM) 2585 (Organic contaminants in house dust) and in settled house dust samples. Results: Target analytes included BPA, 4-tert-octylphenol (OP), OP monoethoxylate, OP diethoxylate, 4-n-nonylphenol (4nNP), 4nNP monoethoxylate (4nNP(1)EO), branched nonylphenol (NP), NP monoethoxylate, NP diethoxylate, NP triethoxylate, and NP tetraethoxylate. The method was sensitive, with method detection limits ranging from 0.05 to 5.1 pg/g, and average recoveries between 82 and 115%. All target analytes were detected in SRM 2585 and house dust except 4nNP and 4nNP(1)EO. Conclusions: The method is simple and fast, with high sensitivity and good reproducibility. It is applicable to the analysis of target analytes in similar matrixes, such as sediments, soil, and biosolids. Highlights: Values measured in SRM 2585 will be useful for future research in method development and method comparison.
引用
收藏
页码:246 / 254
页数:9
相关论文
共 50 条
  • [41] Indirect hydrogen analysis by gas chromatography coupled to mass spectrometry (GC-MS)
    Varlet, V.
    Smith, F.
    Augsburger, M.
    JOURNAL OF MASS SPECTROMETRY, 2013, 48 (08): : 914 - 918
  • [42] Characterization of Cichorium intybus L. Extract in Preventing Oxidative DNA Base Damage Using Gas Chromatography-Tandem Mass Spectrometry (GC-MS/MS)
    Aklan, Acelya
    Aybastier, Onder
    ANALYTICAL LETTERS, 2024,
  • [43] Determination of 39 polychlorinated biphenyls in indoor dust using ultrasonic extraction and gas chromatography-tandem mass spectrometry
    Wang Bingling
    Zhang Xiaoling
    Zhang Qi
    Lu Xiaomei
    Cui Yuan
    Zhang Zhengdong
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2014, 32 (01) : 74 - 80
  • [44] Determination of cannabinoids in hair of CBD rich extracts consumers using gas chromatography with tandem mass spectrometry (GC/MS-MS)
    Rodrigues, Anais
    Yegles, Michel
    Van Elsue, Nicolas
    Schneider, Serge
    FORENSIC SCIENCE INTERNATIONAL, 2018, 292 : 163 - 166
  • [45] Gas chromatography/mass spectrometry (GC/MS) remains a pre-eminent discovery tool in clinical steroid investigations even in the era of fast liquid chromatography tandem mass spectrometry (LC/MS/MS)
    Krone, Nils
    Hughes, Beverly A.
    Lavery, Gareth G.
    Stewart, Paul M.
    Arlt, Wiebke
    Shackleton, Cedric H. L.
    JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 2010, 121 (3-5): : 496 - 504
  • [46] Analysis of Bisphenol A, Nonylphenol, and Natural Estrogens in Vegetables and Fruits Using Gas Chromatography-Tandem Mass Spectrometry
    Lu, Jian
    Wu, Jun
    Stoffella, Peter J.
    Wilson, P. Chris
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2013, 61 (01) : 84 - 89
  • [48] SIMULTANEOUS DETECTION OF MULTICYTOTOXIC DRUGS ON OCCUPATIONAL ENVIRONMENT BY LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY (LC-MS/MS) ANALYSIS
    Ogawa, T.
    Yonemura, M.
    Kawasumi, K.
    Aoyagi, Y.
    Ueno, S.
    Ichida, Y.
    Ohe, Y.
    Endo, K.
    Izumi, K.
    ANNALS OF ONCOLOGY, 2012, 23 : 164 - 165
  • [49] Application of liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the analysis of stable isotope enrichments of phenylalanine and tyrosine
    Meesters, Roland J. W.
    Wolfe, Robert R.
    Deutz, Nicolaas E. P.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (1-2): : 43 - 49
  • [50] Liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the analysis of free metanephrine and free normetanephrine in human
    Lagerstedt, SA
    O'Kane, DJ
    Singh, RJ