The Impact of Intra-Aortic Balloon Pump Weaning Protocols on In-Hospital Clinical Outcomes

被引:10
作者
Manohar, Vinayak A. [1 ]
Levin, Robert N. [1 ]
Karadolian, Sevan S. [1 ]
Usmani, Aimen [1 ]
Timmis, Ryan M. [1 ]
Dery, Megan E. [1 ]
Dixon, Simon R. [1 ]
机构
[1] William Beaumont Hosp, Dept Cardiovasc Med, Royal Oak, MI 48072 USA
关键词
ACUTE MYOCARDIAL-INFARCTION; BENCHMARK REGISTRY; CARDIOGENIC-SHOCK; CARDIAC-SURGERY; UNSTABLE ANGINA; BLOOD-FLOW; COUNTERPULSATION;
D O I
10.1111/j.1540-8183.2011.00708.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Current literature recommends weaning intra-aortic balloon pump (IABP) support prior to discontinuation. To date, no studies have compared various weaning strategies for safety or efficacy. This study was designed to evaluate the impact of weaning on in-hospital clinical outcomes. Methods: From 5/1/07 through 5/1/09 429 patients receiving IABP therapy were retrospectively identified using CPT1 billing codes. The study population and clinical outcomes analysis were stratified by use of weaning protocols versus immediate discontinuation of the IABP. In a subset analysis the patients receiving weaning protocols prior to IABP discontinuation were stratified for further analysis of clinical outcomes by whether they had received 1: 3 ratio counterpulsation during their wean or whether they only received 1: 2 counterpulsation prior to IABP discontinuation. These groups were analyzed for differences in primary and secondary end-points. Results: Of the 429 patients identified, 344 (80.2%) were weaned prior to IABP discontinuation and 85 (19.8%) of the patients had their IABP abruptly discontinued. Patients not weaned had a lower heart rate after IABP discontinuation than those weaned, but no difference in systolic and mean blood pressure or urine output. There was no significant difference in mortality. Weaning was associated with a nonsignificant trend toward increased length of stay. Conclusions: This study suggests that weaning protocols offer no hemodynamic benefits or improvement in in-hospital mortality rates. Weaning is associated with trend toward increased length of stay. We conclude that weaning offers no advantage over direct device removal and would advocate that balloon pumps be directly withdrawn when counterpulsation is terminated. (J Interven Cardiol 2012;25:140-146)
引用
收藏
页码:140 / 146
页数:7
相关论文
共 22 条
[1]  
[Anonymous], WEANING INTRAAORTIC
[2]  
Bavin TK, 1991, AJN, V10, P54
[3]  
BECKMAN CB, 1973, T AM SOC ART INT ORG, V19, P414
[4]  
BOLOOKI H, 1976, J THORAC CARDIOV SUR, V72, P756
[5]  
Bolooki H., 1998, Clinical application of intra-aortic balloon pump, V3rd
[6]   Intra-aortic balloon counterpulsation in US and non-US centres:: Results of the Benchmark® Registry [J].
Cohen, M ;
Urban, P ;
Christenson, JT ;
Joseph, DL ;
Freedman, RJ ;
Miller, MF ;
Ohman, EM ;
Reddy, RC ;
Stone, GW ;
Ferguson, JJ .
EUROPEAN HEART JOURNAL, 2003, 24 (19) :1763-1770
[7]   PROLONGED INTRAAORTIC BALLOON SUPPORT FOR SEPTAL RUPTURE AFTER MYOCARDIAL-INFARCTION [J].
ESTRADAQUINTERO, T ;
URETSKY, BF ;
MURALI, S ;
HARDESTY, RL .
ANNALS OF THORACIC SURGERY, 1992, 53 (02) :335-337
[8]   The current practice of intra-aortic balloon counterpulsation: Results from the Benchmark Registry [J].
Ferguson, JJ ;
Cohen, M ;
Freedman, RJ ;
Stone, GW ;
Miller, MF ;
Joseph, DL ;
Ohman, EM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 38 (05) :1456-1462
[9]   Stabilisation of medically refractory ventricular arrhythmia by intra-aortic balloon counterpulsation [J].
Fotopoulos, GD ;
Mason, MJ ;
Walker, S ;
Jepson, NS ;
Patel, DJ ;
Mitchell, AG ;
Ilsley, CDJ ;
Paul, VE .
HEART, 1999, 82 (01) :96-100
[10]   AUGMENTATION OF REGIONAL CORONARY BLOOD-FLOW BY INTRA-AORTIC BALLOON COUNTERPULSATION IN PATIENTS WITH UNSTABLE ANGINA [J].
FUCHS, RM ;
BRIN, KP ;
BRINKER, JA ;
GUZMAN, PA ;
HEUSER, RR ;
YIN, FCP .
CIRCULATION, 1983, 68 (01) :117-123