Measuring Surface Area of Skin Lesions with 2D and 3D Algorithms

被引:16
作者
Dastjerdi, Houman Mirzaalian [1 ]
Toepfer, Dominique [2 ]
Rupitsch, Stefan J. [3 ]
Maier, Andreas [1 ]
机构
[1] Friedrich Alexander Univ Erlangen Nurnberg FAU, Lehrstuhl Informat 5 Mustererkennung, Erlangen, Germany
[2] Softgate Gmbh, Erlangen, Germany
[3] Friedrich Alexander Univ Erlangen Nurnberg FAU, Lehrstuhl Sensor LSE, Erlangen, Germany
关键词
Geodesy - Image segmentation - Surveying - Errors - Dermatology;
D O I
10.1155/2019/4035148
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose. The treatment of skin lesions of various kinds is a common task in clinical routine. Apart from wound care, the assessment of treatment efficacy plays an important role. In this paper, we present a new approach to measure the skin lesion surface in two and three dimensions. Methods. For the 2D approach, a single photo containing a flexible paper ruler is taken. After semi-automatic segmentation of the lesion, evaluation is based on local scale estimation using the ruler. For the 3D approach, reconstruction is based on Structure from Motion. Roughly outlining the region of interest around the lesion is required for both methods. Results. The measurement evaluation was performed on 117 phantom images and five phantom videos for 2D and 3D approach, respectively. We found an absolute error of 0.99 +/- 1.18cm2 and a relative error 9.89 +/- 9.31% for 2D. These errors are <1cm2 and <5% for five test phantoms in our 3D case. As expected, the error of 2D surface area measurement increased by approximately 10% for wounds on the bent surface compared to wounds on the flat surface. Using our method, the only user interaction is to roughly outline the region of interest around the lesion. Conclusions. We developed a new wound segmentation and surface area measurement technique for skin lesions even on a bent surface. The 2D technique provides the user with a fast, user-friendly segmentation and measurement tool with reasonable accuracy for home care assessment of treatment. For 3D only preliminary results could be provided. Measurements were only based on phantoms and have to be repeated with real clinical data.
引用
收藏
页数:9
相关论文
共 23 条
[1]  
Ahn Chulhyun, 2008, Adv Skin Wound Care, V21, P85, DOI 10.1097/01.ASW.0000305411.58350.7d
[2]   Structure tensor based image interpolation method [J].
Baghaie, Ahmadreza ;
Yu, Zeyun .
AEU-INTERNATIONAL JOURNAL OF ELECTRONICS AND COMMUNICATIONS, 2015, 69 (02) :515-522
[3]   Colorimetric Calibration of Wound Photography with Off-the-shelf Devices [J].
Bala, Subhankar ;
Sirazitdinova, Ekaterina ;
Deserno, Thomas M. .
MEDICAL IMAGING 2017: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2017, 10136
[4]   Comparison of Digital Planimetry and Ruler Technique To Measure ABSSSI Lesion Sizes in the ESTABLISH-1 Study [J].
Bien, Paul ;
De Anda, Carisa ;
Prokocimer, Philippe .
SURGICAL INFECTIONS, 2014, 15 (02) :105-110
[5]   Random forests [J].
Breiman, L .
MACHINE LEARNING, 2001, 45 (01) :5-32
[6]   AN ONLINE ALGORITHM FOR CONSTRAINED DELAUNAY TRIANGULATION [J].
DEFLORIANI, L ;
PUPPO, E .
CVGIP-GRAPHICAL MODELS AND IMAGE PROCESSING, 1992, 54 (04) :290-300
[7]   Ways to increase precision and accuracy of wound area measurement using smart devices: Advanced app Planimator [J].
Foltynski, Piotr .
PLOS ONE, 2018, 13 (03)
[8]   Wound Area Measurement with Digital Planimetry: Improved Accuracy and Precision with Calibration Based on 2 Rulers [J].
Foltynski, Piotr ;
Ladyzynski, Piotr ;
Ciechanowska, Anna ;
Migalska-Musial, Karolina ;
Judzewicz, Grzegorz ;
Sabalinska, Stanislawa .
PLOS ONE, 2015, 10 (08)
[9]   A New Smartphone-Based Method for Wound Area Measurement [J].
Foltynski, Piotr ;
Ladyzynski, Piotr ;
Wojcicki, Jan M. .
ARTIFICIAL ORGANS, 2014, 38 (04) :346-+
[10]  
Gethin G., 2006, Wounds, V2, P60