A simple paper-based ratiometric luminescent sensor for tetracyclines using copper nanocluster-europium hybrid nanoprobes

被引:28
作者
Mo, Mengjiao [1 ]
Wang, Xueshen [1 ]
Ye, Lingyue [1 ]
Su, Yaoquan [1 ]
Zhong, Yang [1 ]
Zhao, Lingzhi [1 ]
Zhou, Yunyun [1 ]
Peng, Juanjuan [1 ]
机构
[1] China Pharmaceut Univ, Sch Basic Med Sci & Clin Pharm, State Key Lab Nat Med, Nanjing 211198, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Tetracyclines; Copper nanoclusters; Ratiometric probe; Europium ion; Paper-sensor device; LIQUID-CHROMATOGRAPHY; ENHANCED-FLUORESCENCE; COMPARATIVE EFFICACY; RAPID-DETERMINATION; GOLD NANOCLUSTERS; GROWTH PROMOTION; RESIDUE ANALYSIS; PHOSPHATE ION; OXYTETRACYCLINE; MILK;
D O I
10.1016/j.aca.2021.339257
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Tetracyclines (TCs), as one of the broad-spectrum antibiotics, are widely used to treat bacterial infections. The residues of TCs in animal-origin foods and drinking water have raised safety concerns and affected the public health. Thus, there is a high demand to develop a simple and rapid method for the detection of TCs. In this work, we developed a ratiometric luminescence probe for the sensitive and visualized detection of TCs. Specifically, tannic acid-stabilized copper nanoclusters (TA-CuNCs) with blue emission at 433 nm were synthesized. The luminescence of TA-CuNCs attenuated partially by the europium ions (Eu3+) due to the aggregation-induced quenching. When TCs were added to the TA-CuNCs-Eu3+ system, the luminescence of TA-CuNCs at 433 nm can be further quenched by the inner-filter effect, and the characteristic luminescence of Eu3+ at 617 nm emerged due to the formation of Eu3+-TCs complex. The ratio of the luminescence at 617 nm-433 nm increased linearly to the concentration of TCs. Additionally, we demonstrated the detection of oxytetracycline in real samples such as tap and lake water, milk, pharmaceutical industry wastewater, honey and soil extract with high recovery rate (97.25%-103.44%). Furthermore, a portable paper device is fabricated by the luminescent probe to conduct the on-site analysis of TCs. (C) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页数:10
相关论文
共 45 条
  • [1] Carbon dots based turn-on fluorescent probes for oxytetracycline hydrochloride sensing
    An, Xuting
    Zhuo, Shujuan
    Zhang, Ping
    Zhu, Changqing
    [J]. RSC ADVANCES, 2015, 5 (26): : 19853 - 19858
  • [2] Hollow ZnS-CdS nanocage based photoelectrochemical sensor combined with molecularly imprinting technology for sensitive detection of oxytetracycline
    Bai, Xinyu
    Zhang, Yao
    Gao, Wenkai
    Zhao, Danyang
    Yang, Dapeng
    Jia, Nengqin
    [J]. BIOSENSORS & BIOELECTRONICS, 2020, 168
  • [3] Copper nanocluster coupling europium as an off-to-on fluorescence probe for the determination of phosphate ion in water samples
    Cao, Haiyan
    Chen, Zhaohui
    Huang, Yuming
    [J]. TALANTA, 2015, 143 : 450 - 456
  • [4] Copper nanoclusters as a highly sensitive and selective fluorescence sensor for ferric ions in serum and living cells by imaging
    Cao, Haiyan
    Chen, Zhaohui
    Zheng, Huzhi
    Huang, Yuming
    [J]. BIOSENSORS & BIOELECTRONICS, 2014, 62 : 189 - 195
  • [5] Immunochemical determination of oxytetracycline in fish: Comparison between enzymatic and time-resolved fluorometric assays
    Chafer-Pericas, Consuelo
    Maquieira, Angel
    Puchades, Rosa
    Miralles, Javier
    Moreno, Amelia
    Pastor-Navarro, Nuria
    Espinos, Francisco
    [J]. ANALYTICA CHIMICA ACTA, 2010, 662 (02) : 177 - 185
  • [6] Chansiripornchai N, 2009, THAI J VET MED, V39, P231
  • [7] Determination of Oxytetracycline and 4-Epi-Oxytetracycline Residues in Feathers and Edible Tissues of Broiler Chickens Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
    Cornejo, Javiera
    Pokrant, Ekaterina
    Krogh, Magdalena
    Briceno, Cristobal
    Hidalgo, Hector
    Maddaleno, Aldo
    Araya-Jordan, Carolina
    San Martins, Betty
    [J]. JOURNAL OF FOOD PROTECTION, 2017, 80 (04) : 619 - 625
  • [8] Probing phosphate ion via the europium(III)-modulated fluorescence of gold nanoclusters
    Ding, Shou-Nian
    Li, Chun-Mei
    Gao, Bu-Hong
    Kargbo, Osman
    Wan, Neng
    Chen, Xi
    Zhou, Chan
    [J]. MICROCHIMICA ACTA, 2014, 181 (15-16) : 1957 - 1963
  • [9] A carbon dot-based fluorometric probe for oxytetracycline detection utilizing a Forster resonance energy transfer mechanism
    Fu, Yanzhao
    Huang, Li
    Zhao, Shaojing
    Xing, Xuejian
    Lan, Minhuan
    Song, Xiangzhi
    [J]. SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2021, 246
  • [10] Comparative efficacy of enrofloxacin, oxytetracycline, and sulfadimethoxine for the control of morbidity and mortality caused by Escherichia coli in broiler chickens
    Glisson, JR
    Hofacre, CL
    Mathis, GF
    [J]. AVIAN DISEASES, 2004, 48 (03) : 658 - 662