Post-implantation erythema in 3 patients and a review of reticular telangiectatic erythema

被引:23
作者
Aneja, Savina [1 ]
Taylor, James S. [2 ]
Billings, Steven D. [3 ]
Honari, Golara [2 ]
Sood, Apra [2 ]
机构
[1] Case Western Reserve Univ, Sch Med, Cleveland, OH USA
[2] Cleveland Clin, Dept Dermatol, Dermatol Plast Surg Inst, Cleveland, OH 44195 USA
[3] Cleveland Clin, Dept Anat Pathol, Cleveland, OH 44195 USA
关键词
implantable device; pacemaker; patch test; post-implantation erythema; prosthesis; reticular telangiectatic erythema; IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR; REACTIVE ANGIOENDOTHELIOMATOSIS; PACEMAKER DERMATITIS; ORTHOPEDIC IMPLANTS; CARDIAC-PACEMAKER; METAL SENSITIVITY; STERNAL ERYTHEMA; DEVICES;
D O I
10.1111/j.1600-0536.2011.01887.x
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
Objective. To demonstrate the variety in clinical presentation of patients presenting with RTE or similar patch test-negative post-implantation erythema. Patients/Materials/Methods. After institutional board approval had been obtained, patient information was obtained from electronic medical record files, which included surgical reports, pathology reports, and notes from outpatient encounters. Results. We report post-implantation erythema following insertion of an elbow prosthesis, a knee prosthesis, and a spinal cord stimulator, which have not previously been cited as aetiologies of RTE. Conclusion. Owing to the delayed onset and variable recovery, RTE remains a diagnostic challenge. RTE should be included in the differential diagnosis of any patient presenting with erythema over the site of a previously implanted device.
引用
收藏
页码:280 / 288
页数:9
相关论文
共 37 条
[11]  
Ferringer Tammie, 2003, Am J Contact Dermat, V14, P37
[12]   Reticulated telangiectatic erythema associated with automatic implanted defibrillator [J].
Garcia, S. M. ;
Gonzalez, I. R. ;
Sambucety, P. S. ;
Prieto, M. A. Rodriguez .
JOURNAL OF THE EUROPEAN ACADEMY OF DERMATOLOGY AND VENEREOLOGY, 2008, 22 (01) :115-116
[13]  
GENSCH EG, 1981, HAUTARZT, V32, P651
[14]  
Gerdsen R, 1999, ACTA DERM-VENEREOL, V79, P385
[15]   Metal sensitivity in patients with orthopedic implants [J].
Hallab, N .
JCR-JOURNAL OF CLINICAL RHEUMATOLOGY, 2001, 7 (04) :215-218
[16]   Reticular telangiectatic erythema associated with an implantable cardioverter defibrillator: An underpublished entity? [J].
Herbst, RA ;
Weiss, J .
ARCHIVES OF DERMATOLOGY, 2003, 139 (01) :100-101
[17]   Hypersensitivity reactions associated with endovascular devices [J].
Honari, Golara ;
Ellis, Stephen G. ;
Wilkoff, Bruce L. ;
Aronica, Mark A. ;
Svensson, Lars G. ;
Taylor, James S. .
CONTACT DERMATITIS, 2008, 59 (01) :7-22
[18]   RETICULAR TELANGIECTATIC ERYTHEMA AFTER IMPLANTATION OF A PACEMAKER [J].
KINT, A ;
VERMANDER, F .
DERMATOLOGICA, 1983, 166 (06) :322-324
[19]   TELEANGIECTATIC PACEMAKER ERYTHEMA [J].
KOPERA, D ;
AUERGRUMBACH, P ;
CERRONI, L ;
SMOLLE, J .
HAUTARZT, 1994, 45 (10) :716-718
[20]   Persistent telangiectatic erythema associated with an automatic implantable cardioverter defibrillator [J].
Krasagakis, K ;
Vogt, R ;
Tebbe, B ;
Goerdt, S .
BRITISH JOURNAL OF DERMATOLOGY, 1997, 136 (04) :633-633