The porous polyethylene (Medpor) spherical orbital implant - A retrospective study of 136 cases

被引:83
作者
Blaydon, SM
Shepler, TR
Neuhaus, RW
White, WL
Shore, JW
机构
[1] Texas Oculoplast Consultants, Austin, TX 78705 USA
[2] Univ Texas, Hlth Sci Ctr, Dept Ophthalmol, San Antonio, TX 78284 USA
[3] USA, Med Dept Ctr & Sch, Ft Sam Houston, TX USA
[4] Brooke Army Med Ctr, Ophthalmol Serv, San Antonio, TX USA
[5] Brackenridge Hosp, Cent Texas Med Fdn, Austin, TX USA
[6] Univ Missouri, Sch Med, Dept Ophthalmol, Kansas City, MO 64108 USA
关键词
HIGH-DENSITY POLYETHYLENE; FIBROVASCULAR INGROWTH; CORALLINE HYDROXYAPATITE; ANOPHTHALMIC SOCKET; TISSUE BREAKDOWN; BONE-GROWTH; EXPERIENCE; COMPLICATIONS; EVISCERATION; ENUCLEATION;
D O I
10.1097/01.IOP.0000083643.36461.84
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate complications and risk factors associated with the placement of wrapped and unwrapped porous polyethylene (PP) spherical implants after evisceration, enucleation, or secondary implantation. Methods: A retrospective, interventional, noncomparative case series of consecutive cases of PP implant placement after anophthalmic socket surgery performed by three surgeons over a 5-year period. A PP spherical implant was placed in 133 patients, 61 women (2 bilaterally) and 72 men (I bilaterally). There were 91 enucleations, 30 eviscerations, and 15 secondary implant placements. Sixty-six (48.5%) implants were wrapped prior to placement. Parameters evaluated included: age, sex, prior ocular surgery or radiation treatment, indications for surgery, procedure performed, size of PP sphere, material used to wrap the implant, and complications. Results: A total of 17 of 136 (12.5%) cases had documented postoperative complications, with implant exposure being the most common. In 5 patients (3.7%), implant exposure developed: I after evisceration and 4 after primary enucleation. Three of the five exposures were small and resolved with either observation alone or in one case with surgical revision of the socket. In two cases, the exposures were large enough that removal of the implant was indicated, one after evisceration and the other after enucleation with placement of a wrapped PP sphere. Conclusions: Our series revealed no significant difference in exposure rate between wrapped and unwrapped PP sphere implants, nor was the exposure rate affected by whether an eye was eviscerated or enucleated.
引用
收藏
页码:364 / 371
页数:8
相关论文
共 32 条
[1]  
[Anonymous], BIOMATERIAL RECONSTR
[2]   The hydroxyapatite orbital implant: A prospective study [J].
Ashworth, JL ;
Rhatigan, M ;
Sampath, R ;
Brammar, R ;
Sunderland, S ;
Leatherbarrow, B .
EYE, 1996, 10 :29-37
[3]   Fibrovascular ingrowth in porous ocular implants: The effect of material composition, porosity, growth factors, and coatings [J].
Bigham, WJ ;
Stanley, P ;
Cahill, JM ;
Curran, RW ;
Perry, AC .
OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 1999, 15 (05) :317-325
[4]   CORRECTION OF ENOPHTHALMOS WITH POROUS POLYETHYLENE IMPLANTS [J].
BILYK, JR ;
RUBIN, PAD ;
SHORE, JW .
INTERNATIONAL OPHTHALMOLOGY CLINICS, 1992, 32 (03) :151-156
[5]   TISSUE BREAKDOWN AND EXPOSURE ASSOCIATED WITH ORBITAL HYDROXYAPATITE IMPLANTS [J].
BUETTNER, H ;
BARTLEY, GB .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1992, 113 (06) :669-673
[6]   Medpor Motility Coupling Post: A rabbit model [J].
Choi, JC ;
Iwamoto, MA ;
Bstandig, S ;
Rubin, PAD ;
Shore, JW .
OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 1999, 15 (03) :190-201
[7]   Postcontrast magnetic resonance imaging assessment of porous polyethylene orbital implant (Medpor) [J].
De Potter, P ;
Duprez, T ;
Cosnard, G .
OPHTHALMOLOGY, 2000, 107 (09) :1656-1660
[8]  
DUTTON JJ, 1991, OPHTHALMOLOGY, V98, P370
[9]   MANAGEMENT OF TISSUE BREAKDOWN AND EXPOSURE ASSOCIATED WITH ORBITAL HYDROXYAPATITE IMPLANTS [J].
ELSHAHED, FS ;
SHERIF, MM ;
ALI, AT .
OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 1995, 11 (02) :91-94
[10]  
GOLDBERG RA, 1992, OPHTHALMOLOGY, V99, P831