共 54 条
Effect of the second-step voltages on the structural and corrosion properties of silicon-calcium-phosphate (Si-CaP) coatings on Mg-Zn-Ca alloy
被引:19
作者:
Dou, Jinhe
[1
,2
]
Zhao, Yupeng
[1
,2
]
Lu, Lu
[1
,2
]
Gu, Guochao
[1
,2
]
Yu, Huijun
[1
,3
,4
]
Chen, Chuanzhong
[1
,2
]
机构:
[1] Shandong Univ, Shenzhen Res Inst, Shenzhen 518057, Guangdong, Peoples R China
[2] Shandong Univ, Key Lab Liquid Solid Struct Evolut & Proc Mat, Minist Educ, Sch Mat Sci & Engn, Jinan 250061, Shandong, Peoples R China
[3] Shandong Univ, Key Lab High Efficiency & Clean Mech Manufacture, Minist Educ, Sch Mech Engn, Jinan 250061, Shandong, Peoples R China
[4] Shandong Univ, Natl Demonstrat Ctr Expt Mech Engn Educ, Sch Mech Engn, Jinan 250061, Shandong, Peoples R China
关键词:
Si-CaP coating;
second step;
micro-arc oxidation;
magnesium alloy;
corrosion behaviour;
MICRO-ARC OXIDATION;
PLASMA ELECTROLYTIC OXIDATION;
MAGNESIUM ALLOYS;
CERAMIC COATINGS;
IN-VIVO;
OXIDIZED MAGNESIUM;
PURE MAGNESIUM;
BONE-FORMATION;
BEHAVIOR;
RESISTANCE;
D O I:
10.1098/rsos.172410
中图分类号:
O [数理科学和化学];
P [天文学、地球科学];
Q [生物科学];
N [自然科学总论];
学科分类号:
07 ;
0710 ;
09 ;
摘要:
The applications of magnesium (Mg) alloys as biodegradable orthopedic implants are mainly restricted due to their rapid degradation rate in the physiological environment. In this study, Si-CaP micro-arc oxidation (MAO) coatings were prepared on a Mg-Zn-Ca alloy by a second-step MAO process at different voltages in order to decrease the degradation rate and increase the bioactivity of the alloy. The microstructure and morphology of the samples were characterized using XRD, FT-IR SEM and EDS. The degradation behaviours of samples were evaluated using electrochemical techniques, and immersion tests in simulated body fluid (SBF). The results indicate that the morphology of the Si-CaP coatings changed significantly with the increase in Ca/P ratio as the second-step voltage increased. The Si- CaP containing coating produced at 450 V could significantly decrease the degradation rate of Mg and caused a slow increase in pH of the SBF solution. The haemolysis test concluded that the coating C3 did not cause a haemolytic reaction. The corrosion resistance of Mg alloy was greatly improved with the Si-CaP coatings, and the Mg alloy with Si-CaP coating prepared at 450 V had the best corrosion resistance, which indicates that the Si-CaP coatings are promising for improving the biodegradation properties of Mg-based orthopedic implants. Haemolysis tests indicated that the Si-CaP coating prepared at 450 V conforms to the given standard (YY/T0127.1-93).
引用
收藏
页数:14
相关论文