Evaluation of leukocyte esterase and nitrite strip tests to detect spontaneous bacterial peritonitis in cirrhotic patients

被引:18
作者
Torun, Serkan
Dolar, Enver
Yilmaz, Yusuf [1 ]
Keskin, Murat
Kiyici, Murat
Sinirtas, Melda
Sarandol, Emre
Gurel, Selim
Nak, Selim Giray
Gulten, Macit
机构
[1] Uludag Univ, Fak Hastaliklari, TR-16059 Bursa, Turkey
[2] Uludag Univ Med Sch, Dept Gastroenterol, TR-16059 Bursa, Turkey
[3] Uludag Univ Med Sch, Dept Microbiol & Infect Dis, TR-16059 Bursa, Turkey
[4] Uludag Univ Med Sch, Dept Biochem, TR-16059 Bursa, Turkey
关键词
spontaneous bacterial peritonitis; urinary reagent strip; leukocyte esterase; nitrite;
D O I
10.3748/wjg.13.6027
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
AIM: To investigate the diagnostic efficacy of leukocyte esterase and nitrite reagent strips for bedside diagnosis of spontaneous bacterial peritonitis (SBP). METHODS: A total of 63 consecutive patients with cirrhotic ascites (38 male, 25 female) tested between April 2005 and July 2006 were included in the study. Bedside reagent strip testing was performed on ascitic fluid and the results compared to manual cell counting and ascitic fluid culture. SBP was defined as having a polymorphonuclear ascites count of >= 250/mm(3). RESULTS: Fifteen samples showed SBP The sensitivity, specificity, positive and negative predictive values of the leukocyte esterase reagent strips were; 93%, 100%, 100%, and 98%, respectively. The sensitivity, specificity, positive and negative predictive value of the nitrite reagent strips were 13%, 93%, 40%, and 77%, respectively. The combination of leukocyte esterase and nitrite reagents strips did not yield statistically significant effects on diagnostic accuracy. CONCLUSION: Leukocyte esterase reagent strips may provide a rapid, bedside diagnostic test for SBP (c) 2007 WJG. All rights reserved.
引用
收藏
页码:6027 / 6030
页数:4
相关论文
共 30 条
[1]   MEASUREMENT OF NITRIC-OXIDE IN BIOLOGICAL MODELS [J].
ARCHER, S .
FASEB JOURNAL, 1993, 7 (02) :349-360
[2]   Rapid diagnosis of infectious pleural effusions by use of reagent strips [J].
Azoulay, E ;
Fartoukh, M ;
Galliot, R ;
Baud, F ;
Simonneau, G ;
Le Gall, JR ;
Schlemmer, B ;
Chevret, S .
CLINICAL INFECTIOUS DISEASES, 2000, 31 (04) :914-919
[3]   Measurement of nitrite and nitrate levels in plasma and urine - what does this measure tell us about the activity of the endogenous nitric oxide system? [J].
Baylis, C ;
Vallance, P .
CURRENT OPINION IN NEPHROLOGY AND HYPERTENSION, 1998, 7 (01) :59-62
[4]   Long-lasting NO overproduction in cirrhotic patients with spontaneous bacterial peritonitis [J].
Bories, PN ;
Campillo, B ;
Azaou, L ;
Scherman, E .
HEPATOLOGY, 1997, 25 (06) :1328-1333
[5]   Diagnostic value of two reagent strips (Multistix® 8 SG and Combur® 2 LN) in cirrhotic patients with spontaneous bacterial peritonitis and symptomatic bacterascites [J].
Campillo, B ;
Richardet, JP ;
Dupeyron, C .
GASTROENTEROLOGIE CLINIQUE ET BIOLOGIQUE, 2006, 30 (03) :446-452
[6]   Rapid diagnosis of spontaneous bacterial peritonitis by use of reagent strips [J].
Castellote, J ;
López, C ;
Gornals, J ;
Tremosa, G ;
Fariña, ER ;
Baliellas, C ;
Domingo, A ;
Xiol, X .
HEPATOLOGY, 2003, 37 (04) :893-896
[7]   Serum and ascitic fluid nitrate levels in patients with cirrhosis [J].
Coskun, U ;
Özenirler, S ;
Sancak, B ;
Bukan, N .
CLINICA CHIMICA ACTA, 2001, 306 (1-2) :127-132
[8]   NITRIC-OXIDE IN BIOLOGICAL-FLUIDS - ANALYSIS OF NITRITE AND NITRATE BY HIGH-PERFORMANCE ION CHROMATOGRAPHY [J].
EVERETT, SA ;
DENNIS, MF ;
TOZER, GM ;
PRISE, VE ;
WARDMAN, P ;
STRATFORD, MRL .
JOURNAL OF CHROMATOGRAPHY A, 1995, 706 (1-2) :437-442
[9]  
Farmer CKT, 2000, PERITON DIALYSIS INT, V20, P237
[10]  
Garcia Xiomara, 2006, Semin Pediatr Infect Dis, V17, P55, DOI 10.1053/j.spid.2006.04.002