Wear analysis of retrieved ceramic-on-ceramic articulations in total hip arthroplasty: Femoral head makes contact with the rim of the socket outside of the bearing surface

被引:20
|
作者
Yamamoto, T
Saito, M
Ueno, M
Hananouchi, T
Tokugawa, Y
Yonenobu, K
机构
[1] Osaka Minami Med Ctr, Dept Orthopaed Surg, Kawachi Nagano 5868521, Japan
[2] Kyocera Corp, Bioceram Div, Kyoto, Japan
关键词
ceramic; implant retrieval; in vivo; total joint replacement; surface analysis;
D O I
10.1002/jbm.b.30215
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We investigated articular bearing surfaces retrieved from three patients with ceramic-on-ceramic total hip arthroplasties using high-quality alumina. The duration of implantation was 3.5, 3.0, and 2.5 years, respectively. Dislocation of the hip joint after implantation did not occur in any patients. The retrieved prostheses were examined by stereomicroscopy and scanning electron microscopy (SEM). In the main load-bearing area, no wear marks were seen in any sockets. However, in all three cases, stripe scars were observed at the rim of the alumina inlay under stereomicroscopy, despite the lack of indentation in the socket and the stem, which suggests impingement. Such scars were not observed on the load-bearing surface. Under SEM, the scars showed excessive wear, including material excavation, that has not been observed in conventional hip simulator experiments. These findings are similar to those of experiments in which a simulator was programmed to distract the femoral head from the socket. The present results suggest that the femoral head can separate from the socket without neck-socket impingement in vivo. (c) 2005 Wiley Periodicals, Inc.
引用
收藏
页码:301 / 307
页数:7
相关论文
共 21 条
  • [1] Fracture of a ceramic femoral head after ceramic-on-ceramic total hip arthroplasty
    Malillos Toran, Manuel
    Cuenca, Jorge
    Antonio Martinez, Angel
    Herrera, Antonio
    Vicente Thomas, Javier
    JOURNAL OF ARTHROPLASTY, 2006, 21 (07): : 1072 - 1073
  • [2] Can Squeaking With Ceramic-On-Ceramic Hip Articulations In Total Hip Arthroplasty Be Avoided?
    Kiyama, Takahiko
    Kinsey, Tracy L.
    Mahoney, Ormonde M.
    JOURNAL OF ARTHROPLASTY, 2013, 28 (06): : 1015 - 1020
  • [3] Revision of Ceramic Head Fracture After Third Generation Ceramic-on-Ceramic Total Hip Arthroplasty
    Koo, Kyung-Hoi
    Ha, Yong-Chan
    Kim, Shin-Yoon
    Yoon, Kang-Sup
    Min, Byung-Woo
    Kim, Sang-Rim
    JOURNAL OF ARTHROPLASTY, 2014, 29 (01): : 214 - 218
  • [4] Incidence, Risk Factors, and Outcome of Ceramic-On-Ceramic Bearing Breakage in Total Hip Arthroplasty
    Hoskins, Wayne
    Rainbird, Sophia
    Peng, Yi
    Lorimer, Michelle
    Graves, Stephen E.
    Bingham, Roger
    JOURNAL OF ARTHROPLASTY, 2021, 36 (08): : 2992 - 2997
  • [5] Incidence of Ceramic Fracture in Contemporary Ceramic-on-Ceramic Total Hip Arthroplasty: A Meta-analysis of Proportions
    Yoon, Byung-Ho
    Park, Jung-Wee
    Cha, Yong-Han
    Won, Suk-Hyung
    Lee, Young-Kyun
    Ha, Yong-Chan
    Koo, Kyung-Hoi
    JOURNAL OF ARTHROPLASTY, 2020, 35 (05): : 1437 - +
  • [6] A Randomized Trial Of Ceramic-On-Ceramic Bearing Versus Ceramic-On-Crossfire-Polyethylene Bearing In Total Hip Arthroplasty: Five-Year Outcomes
    Beaupre, Lauren A.
    Manolescu, Andrei
    Johnston, D. W. C.
    JOURNAL OF ARTHROPLASTY, 2013, 28 (03): : 485 - 489
  • [7] Cutaneous metallosis following ceramic insert fracture in total hip arthroplasty: a case report and revision with ceramic-on-ceramic bearing couple
    Giovanoulis, Vasileios
    Vasiliadis, Angelo V.
    Marmor, Simon
    SICOT-J, 2025, 11
  • [8] Is a ceramic-on-ceramic bearing really superior to ceramic-on-polyethylene for primary total hip arthroplasty? A systematic review and meta-analysis of randomised controlled trials
    Si, Hai-bo
    Zeng, Yi
    Cao, Fei
    Pei, Fu-xing
    Shen, Bin
    HIP INTERNATIONAL, 2015, 25 (03) : 191 - 198
  • [9] Zirconia Phase Transformation, Metal Transfer, and Surface Roughness in Retrieved Ceramic Composite Femoral Heads in Total Hip Arthroplasty
    Elpers, Marcella
    Nam, Denis
    Boydston-White, Susie
    Ast, Michael P.
    Wright, Timothy M.
    Padgett, Douglas E.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (11): : 2219 - 2223
  • [10] Wear rates of ceramic-on-ceramic bearing surfaces in total hip implants - A 12-year follow-up study
    Jazrawi, LM
    Bogner, E
    Della Valle, CJ
    Chen, FS
    Pak, KI
    Stuchin, SA
    Frankel, VH
    Di Cesare, PE
    JOURNAL OF ARTHROPLASTY, 1999, 14 (07): : 781 - 787