Glucose effectiveness and insulin sensitivity measurements derived from the non-insulin-assisted minimal model and the clamp techniques are concordant

被引:10
|
作者
Henriksen, Jan Erik [1 ]
Alford, Frank [2 ]
Ward, Glenn [2 ]
Thye-Ronn, Peter [1 ]
Levin, Klaus [1 ]
Hother-Nielsen, Ole [1 ]
Rantzau, Christian [3 ]
Boston, Ray [4 ]
Beck-Nielsen, Henning [1 ]
机构
[1] Odense Univ Hosp, Dept Endocrinol M, Diabet Res Ctr, DK-5000 Odense C, Denmark
[2] St Vincent Hosp, Dept Endocrinol & Diabet, Melbourne, Vic, Australia
[3] Univ Melbourne, Heidelberg Repatriat Hosp, Dept Med, Melbourne, Vic, Australia
[4] Univ Penn, NBC, Sch Vet Med, Dept Clin Studies, Philadelphia, PA 19104 USA
基金
英国医学研究理事会;
关键词
non-insulin unmodified assisted IVGTT; basal insulinaemic eu-hyperglycaemic clamps; SAAM/CONSAM implementation of minimal model; SG; SI; acute insulin release; TOLERANCE TEST; SECRETION; DISPOSAL; INDEX; CELL; SE; HYPERGLYCEMIA; RELATIVES; VOLUME;
D O I
10.1002/dmrr.1127
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background We investigated the concordance between glucose effectiveness (SG) and insulin sensitivity (SI), derived from the unmodified dynamic non-insulin-assisted intravenous glucose tolerance test (IVGTT) implemented by SG(MM) and SIMM; simulation analysis and modelling/conversational interaction (SAAM/CONSAM) versus the eu/hyperglycaemic basal insulinaemic and the euglycaemic hyperinsulinaemic clamp (SG(CLAMP) and SICLAMP). Methods Twenty-seven of 30 normoglycaemic subjects completed a (1) euglycaemic hyperinsulinaemic clamp, (2) 6-h eu/hyperglycaemic near-normoinsulinaemic pancreatic clamp with hyperglycaemia present over the final 2 h of the clamp (Day 2 study), (3) identical clamp to (2) but with euglycaemia maintained over the entire 6 h (Day 3 study) and (4) IVGTT. SG(CLAMP) was calculated in two ways based on data from study (2) alone (Day 2 SG(CLAMP 210-240')) or from data from study day (2) and (3) (Day 2-3 SG(CLAMP 330-360')). Results SG(MM) was unrelated to the magnitude of endogenous insulin release (AIR). The single-day (Day 2) and two-day (Day 2 and 3) SG(CLAMP) protocols correlated (r = 0.72, p = 0.003), but SG(CLAMP 210-240') was significantly (p = 0.001) higher than SG(CLAMP 330-360'). Employing the Day 2 and 3 SG(CLAMP) protocol, the whole body SG(CLAMP 330-360') was similar to SG(MM) (1.80 +/- 0.82 versus 1.73 +/- 0.58 dL/min) and correlated (r = 0.45, p < 0.02). SG(CLAMP 210-240') did not correlate with SG(MM) (r = 0.24). SIMM and SICLAMP were similar (0.093 +/- 0.060 versus 0.087 +/- 0.029 dL/min per mU/L) and correlated (r = 0.76, p < 0.001). Conclusions The time-dependent increase in glucose disposal observed during a prolonged 6-h clamp significantly influences the estimation of SG(CLAMP), and significant concordance coefficients are observed between SG(MM), and SG(CLAMP 330-360'), and SIMM and SICLAMP. Copyright (C) 2010 John Wiley & Sons, Ltd.
引用
收藏
页码:569 / 578
页数:10
相关论文
共 50 条
  • [31] Correlation of oral glucose tolerance test-derived estimates of insulin sensitivity with insulin clamp measurements in an African-American cohort
    Cheng, C
    Campbell, KL
    Kushner, H
    Falkner, BE
    METABOLISM-CLINICAL AND EXPERIMENTAL, 2004, 53 (09): : 1107 - 1112
  • [32] Minimal Model-Derived Insulin Sensitivity Index Underestimates Insulin Sensitivity in Black Americans
    Fosam, Andin
    Yuditskaya, Susan
    Sarcone, Camila
    Grewal, Shivraj
    Fan, Hubert
    Muniyappa, Ranganath
    DIABETES CARE, 2021, 44 (11) : 2586 - 2588
  • [33] Assessing glucose effectiveness with the minimal model: Insights from an IVGTT at basal insulin
    Caumo, A
    Meregalli, G
    Ghelardi, R
    Scotto, S
    Mangili, R
    Pontiroli, AE
    Cobelli, C
    DIABETOLOGIA, 1997, 40 : 1101 - 1101
  • [34] The oral glucose minimal model: Estimation of insulin sensitivity from a meal test
    Dalla Man, C
    Caumo, A
    Cobelli, C
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2002, 49 (05) : 419 - 429
  • [35] Evaluation of insulin sensitivity from a minimal model adapted to oral glucose tests
    Di Nardo, F
    Casagrande, F
    Carle, F
    Boemi, M
    Fumelli, P
    Morosini, P
    Burattini, R
    MODELLING IN MEDICINE AND BIOLOGY VI, 2005, 8 : 67 - 76
  • [36] Insulin sensitivity and glucose effectiveness estimated by the minimal model technique in spontaneously hypertensive and normal rats
    Natalucci, S
    Ruggeri, P
    Cogo, CE
    Picchio, V
    Burattini, R
    EXPERIMENTAL PHYSIOLOGY, 2000, 85 (06) : 775 - 781
  • [37] The hot IVGTT two-compartment minimal model: indexes of glucose effectiveness and insulin sensitivity
    Vicini, P
    Caumo, A
    Cobelli, C
    AMERICAN JOURNAL OF PHYSIOLOGY-ENDOCRINOLOGY AND METABOLISM, 1997, 273 (05): : E1024 - E1032
  • [38] REDUCED SAMPLING PROTOCOLS IN ESTIMATION OF INSULIN SENSITIVITY AND GLUCOSE EFFECTIVENESS USING THE MINIMAL MODEL IN NIDDM
    COATES, PA
    OLLERTON, RL
    LUZIO, SD
    ISMAIL, IS
    OWENS, DR
    DIABETES, 1993, 42 (11) : 1635 - 1641
  • [39] Measurement of insulin sensitivity in pregnancy with glucose clamps and the minimal model
    Buchanan, TA
    MINIMAL MODEL APPROACH AND DETERMINANTS OF GLUCOSE TOLERANCE, 1997, 7 : 323 - 343
  • [40] Insulin Clamp-Derived Measurements of Insulin Sensitivity and Insulin Secretion in Lean and Obese Asian Type 2 Diabetic Patients
    Suraamornkul, Swangjit
    Kwancharoen, Rachaneewon
    Ovartlarnporn, Mudjalin
    Rawdaree, Petch
    Bajaj, Mandeep
    METABOLIC SYNDROME AND RELATED DISORDERS, 2010, 8 (02) : 113 - 117