Psychological response based on the indoor environmental quality (IEQ) condition changes and activities of the occupants, can be assessed via indoor air quality (IAQ) satisfaction and thermal comfort. However, it is difficult to analyze both indices at the same time because they are measured on different scales. Therefore, this study aimed to develop an integrated psychological response score of the occupants based on 22 experimental participants' activities and the IEQ condition changes by using the weighted Euclidean distance. For this purpose, the experiment was designed with three scenarios to simulate the IEQ condition changes (i.e., CO2 concentration and operative temperature) during an 8-h working period. In each scenario, six cognitive tasks that simulate office work were performed to consider the activities of the occupants. A questionnaire survey on IAQ satisfaction and thermal comfort was conducted before and after (i) office work and (ii) IEQ condition changes. As a result, when the operative temperature was changed from 18.70 degrees C (cold) to 25 degrees C (neutral), the best psychological response score was calculated as 0.335. In addition, the occupants were more affected by the operative temperature than the CO2 concentration. It was shown that the mental health status based on IEQ condition, while considering both the indoor air pollutant and indoor climate, could be expressed as a single index. The mechanical system designer and facility manager can design or operate the IEQ condition considering the integrated psychological response score of the occupants, which can be used as an IEQ condition management guideline for mental health. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:66 / 77
页数:12
相关论文
共 63 条
[1]   Predictive model for CO2 generation and decay in building envelopes [J].
Aglan, HA .
JOURNAL OF APPLIED PHYSICS, 2003, 93 (02) :1287-1290
[2]  
ASHRAE ANSI/ASHRAE, 2004, 62 ASHRAE ANSI
[3]  
Auliciems A., 1997, THERMAL COMFORT, V2nd
[4]   Occupant comfort in UK offices - How adaptive comfort theories might influence future low energy office refurbishment strategies [J].
Barlow, Stuart ;
Fiala, Dusan .
ENERGY AND BUILDINGS, 2007, 39 (07) :837-846
[5]  
Brace N., 2016, SPSS for psychologists and everybody else
[6]   Adaptive analysis of thermal comfort in university classrooms: Correlation between experimental data and mathematical models [J].
Buratti, Cinzia ;
Ricciardi, Paola .
BUILDING AND ENVIRONMENT, 2009, 44 (04) :674-687
[7]   Thermal comfort study of an air-conditioned lecture theatre in the tropics [J].
Cheong, KWD ;
Djunaedy, E ;
Chua, YL ;
Tham, KW ;
Sekhar, SC ;
Wong, NH ;
Ullah, MB .
BUILDING AND ENVIRONMENT, 2003, 38 (01) :63-73
[8]  
Clements D.H., 1999, TEACHING CHILDREN MA, V5, P400, DOI [10.5951/tcm.5.7.0400, DOI 10.5951/TCM.5.7.0400]
[9]   Thermal sensations and comfort investigations in transient conditions in tropical office [J].
Dahlan, Nur Dalilah ;
Gital, Yakubu Yau .
APPLIED ERGONOMICS, 2016, 54 :169-176
[10]   Indoor air quality, ventilation and health symptoms in schools: an analysis of existing information [J].
Daisey, JM ;
Angell, WJ ;
Apte, MG .
INDOOR AIR, 2003, 13 (01) :53-64